gsd-2021-22681
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
Aliases
Aliases
{ GSD: { alias: "CVE-2021-22681", description: "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.", id: "GSD-2021-22681", }, gsd: { metadata: { exploitCode: "unknown", remediation: "unknown", reportConfidence: "confirmed", type: "vulnerability", }, osvSchema: { aliases: [ "CVE-2021-22681", ], details: "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.", id: "GSD-2021-22681", modified: "2023-12-13T01:23:24.668469Z", schema_version: "1.4.0", }, }, namespaces: { "cve.org": { CVE_data_meta: { ASSIGNER: "ics-cert@hq.dhs.gov", ID: "CVE-2021-22681", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers", version: { version_data: [ { version_value: "RSLogix 5000 Versions 16 through 20", }, { version_value: "Studio 5000 Logix Designer: Versions 21 and later", }, { version_value: "CompactLogix 1768, 1769, 5370, 5380, 5480", }, { version_value: "ControlLogix 5550, 5560, 5570, 5580", }, { version_value: "DriveLogix 5560, 5730, 1794-L34", }, { version_value: "Compact GuardLogix 5370, 5380", }, { version_value: "GuardLogix 5570, 5580", }, { version_value: "SoftLogix 5800", }, ], }, }, ], }, vendor_name: "n/a", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "Insufficiently Protected Credentials CWE-522", }, ], }, ], }, references: { reference_data: [ { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03", refsource: "MISC", url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03", }, ], }, }, "nvd.nist.gov": { configurations: { CVE_data_version: "4.0", nodes: [ { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.10", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:rockwellautomation:rslogix_5000:*:*:*:*:*:*:*:*", cpe_name: [], versionEndIncluding: "20", versionStartIncluding: "16", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "21.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:rockwellautomation:compact_guardlogix_5370:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compactlogix_1768:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compactlogix_1769:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compactlogix_5370:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:controllogix_5550:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:controllogix_5560:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:controllogix_5570:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:drivelogix_1794-l34:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:drivelogix_5560:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:drivelogix_5730:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:guardlogix_5570:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, { cpe23Uri: "cpe:2.3:h:rockwellautomation:softlogix_5800:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, ], }, cve: { CVE_data_meta: { ASSIGNER: "ics-cert@hq.dhs.gov", ID: "CVE-2021-22681", }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "en", value: "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "en", value: "CWE-522", }, ], }, ], }, references: { reference_data: [ { name: "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03", refsource: "MISC", tags: [ "Third Party Advisory", "US Government Resource", ], url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03", }, ], }, }, impact: { baseMetricV2: { acInsufInfo: false, cvssV2: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 7.5, confidentialityImpact: "PARTIAL", integrityImpact: "PARTIAL", vectorString: "AV:N/AC:L/Au:N/C:P/I:P/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 6.4, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, severity: "HIGH", userInteractionRequired: false, }, baseMetricV3: { cvssV3: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 9.8, baseSeverity: "CRITICAL", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 5.9, }, }, lastModifiedDate: "2022-04-25T16:16Z", publishedDate: "2021-03-03T18:15Z", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.