gsd-2011-4859
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2011-4859",
"description": "The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port.",
"id": "GSD-2011-4859"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2011-4859"
],
"details": "The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port.",
"id": "GSD-2011-4859",
"modified": "2023-12-13T01:19:06.057677Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-4859",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "http://reversemode.com/index.php?option=com_content\u0026task=view\u0026id=80\u0026Itemid=1",
"refsource": "MISC",
"url": "http://reversemode.com/index.php?option=com_content\u0026task=view\u0026id=80\u0026Itemid=1"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-018-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-018-01.pdf"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-backdoor(72587)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72587"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-346-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-346-01.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140cpu65150:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140cpu65160:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140cpu65260:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77101:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.9",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77111:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77100:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.4",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:quantum_ethernet_module_140noe77100:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp573634m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.9",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp574634m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp575634m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp576634m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxety4103:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxety5103:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp57163m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.9",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:premium_ethernet_module_tsxp572634m:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.9",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:m340_ethernet_module_bmxnoe0110:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.65",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:m340_ethernet_module_bmxnoe0100:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:m340_ethernet_module_bmxp342030:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:m340_ethernet_module_bmxp342020:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:stb_dio_ethernet_module_stbnic2212:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.10",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:stb_dio_ethernet_module_stbnip2311:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.01",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:stb_dio_ethernet_module_stbnip2212:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.73",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-4859"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-346-01.pdf",
"refsource": "MISC",
"tags": [],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-346-01.pdf"
},
{
"name": "http://reversemode.com/index.php?option=com_content\u0026task=view\u0026id=80\u0026Itemid=1",
"refsource": "MISC",
"tags": [],
"url": "http://reversemode.com/index.php?option=com_content\u0026task=view\u0026id=80\u0026Itemid=1"
},
{
"name": "51605",
"refsource": "BID",
"tags": [],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"tags": [],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"tags": [],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-018-01.pdf",
"refsource": "MISC",
"tags": [],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-018-01.pdf"
},
{
"name": "schneider-modicon-backdoor(72587)",
"refsource": "XF",
"tags": [],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72587"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2017-08-29T01:30Z",
"publishedDate": "2011-12-17T11:55Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…