"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:27.908Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X202-2 IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X204 IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X204 IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE X204-2 (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2FM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X206-1LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208 (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2 (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204 IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE XF204-2 (incl. SIPLUS NET variant)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.5.1"
}
]
},
{
"product": "SCALANCE XF206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:24",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25669",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE X200-4P IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X201-3P IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X201-3P IRT PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X202-2 IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X202-2P IRT PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X204 IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X204 IRT PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE X204-2 (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X204-2FM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X204-2LD (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X204-2LD TS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X204-2TS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X206-1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X206-1LD",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X208 (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X208PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X212-2 (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X212-2LD",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X216",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE X224",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE XF201-3P IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE XF202-2P IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE XF204",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE XF204 IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE XF204-2 (incl. SIPLUS NET variant)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE XF204-2BA IRT",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 5.5.1"
}
]
}
},
{
"product_name": "SCALANCE XF206-1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
},
{
"product_name": "SCALANCE XF208",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.2.5"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-25669",
"datePublished": "2021-04-22T20:42:20",
"dateReserved": "2021-01-21T00:00:00",
"dateUpdated": "2024-08-03T20:11:27.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}