fkie_cve-2025-34070
Vulnerability from fkie_nvd
Published
2025-07-02 14:15
Modified
2025-09-17 13:56
Severity ?
Summary
A missing authentication vulnerability in the GFIAgent component of GFI Kerio Control 9.4.5 allows unauthenticated remote attackers to perform privileged operations. The GFIAgent service, responsible for integration with GFI AppManager, exposes HTTP services on ports 7995 and 7996 without proper authentication. The /proxy handler on port 7996 allows arbitrary forwarding to administrative endpoints when provided with an Appliance UUID, which itself can be retrieved from port 7995. This results in a complete authentication bypass, permitting access to sensitive administrative APIs.
Impacted products
Vendor Product Version
gfi kerio_control 9.4.5



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:gfi:kerio_control:9.4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "4466D8DD-63A6-4BE1-B9CB-3C7529D8AC2C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A missing authentication vulnerability in the GFIAgent component of GFI Kerio Control 9.4.5 allows unauthenticated remote attackers to perform privileged operations. The GFIAgent service, responsible for integration with GFI AppManager, exposes HTTP services on ports 7995 and 7996 without proper authentication. The /proxy handler on port 7996 allows arbitrary forwarding to administrative endpoints\u00a0when provided with an Appliance UUID, which itself can be retrieved from port 7995. This results in a complete authentication bypass, permitting access to sensitive administrative APIs."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de falta de autenticaci\u00f3n en el componente GFIAgent de GFI Kerio Control 9.4.5 permite a atacantes remotos no autenticados realizar operaciones privilegiadas. El servicio GFIAgent, responsable de la integraci\u00f3n con GFI AppManager, expone servicios HTTP en los puertos 7995 y 7996 sin la autenticaci\u00f3n adecuada. El controlador /proxy del puerto 7996 permite el reenv\u00edo arbitrario a endpoints administrativos cuando se le proporciona un UUID de dispositivo, que a su vez puede obtenerse del puerto 7995. Esto resulta en una omisi\u00f3n completa de la autenticaci\u00f3n, lo que permite el acceso a API administrativas confidenciales."
    }
  ],
  "id": "CVE-2025-34070",
  "lastModified": "2025-09-17T13:56:58.470",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "HIGH",
          "subIntegrityImpact": "HIGH",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-02T14:15:24.527",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://ssd-disclosure.com/ssd-advisory-kerio-control-authentication-bypass-and-rce/"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vulncheck.com/advisories/gfi-kerio-control-auth-bypass-rce"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…