fkie_cve-2025-26469
Vulnerability from fkie_nvd
Published
2025-07-28 14:15
Modified
2025-11-03 20:18
Severity ?
9.3 (Critical) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
An incorrect default permissions vulnerability exists in the CServerSettings::SetRegistryValues functionality of MedDream PACS Premium 7.3.3.840.
A specially crafted application can decrypt credentials stored in a configuration-related registry key.
An attacker can execute a malicious script or application to exploit this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| meddream | pacs_server | 7.3.2.840 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:meddream:pacs_server:7.3.2.840:*:*:*:premium:*:*:*",
"matchCriteriaId": "2FEB620B-C8F8-418B-B5AC-6CCDE305AA68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An incorrect default permissions vulnerability exists in the CServerSettings::SetRegistryValues functionality of MedDream PACS Premium 7.3.3.840.\r\nA specially crafted application can decrypt credentials stored in a configuration-related registry key.\r\nAn attacker can execute a malicious script or application to exploit this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de permisos predeterminados incorrectos en la funci\u00f3n CServerSettings::SetRegistryValues de MedDream PACS Premium 7.3.3.840. Una aplicaci\u00f3n especialmente manipulada puede descifrar las credenciales almacenadas en una clave de registro relacionada con la configuraci\u00f3n. Un atacante puede ejecutar un script o aplicaci\u00f3n maliciosa para explotar esta vulnerabilidad."
}
],
"id": "CVE-2025-26469",
"lastModified": "2025-11-03T20:18:01.450",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.5,
"impactScore": 6.0,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2025-07-28T14:15:26.290",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2154"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2154"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…