FKIE_CVE-2025-11785

Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2025-12-03 19:13
Severity ?
Summary
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [
    {
      "sourceIdentifier": "cve-coordination@incibe.es",
      "tags": [
        "unsupported-when-assigned"
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterPasswords()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027ShowMeterPasswords()\u0027, existe una entrada de usuario ilimitada que se copia a un b\u00fafer de tama\u00f1o fijo a trav\u00e9s de \u0027sprintf()\u0027. La funci\u00f3n \u0027GetParameter(meter)\u0027 recupera la entrada del usuario, la cual se incorpora directamente en un b\u00fafer sin validaci\u00f3n de tama\u00f1o. Un atacante puede proporcionar una entrada excesivamente grande para el par\u00e1metro \u0027meter\u0027."
    }
  ],
  "id": "CVE-2025-11785",
  "lastModified": "2025-12-03T19:13:22.060",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "HIGH",
          "subIntegrityImpact": "LOW",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cve-coordination@incibe.es",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-12-02T13:15:50.223",
  "references": [
    {
      "source": "cve-coordination@incibe.es",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
    }
  ],
  "sourceIdentifier": "cve-coordination@incibe.es",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cve-coordination@incibe.es",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…