FKIE_CVE-2025-10541

Vulnerability from fkie_nvd - Published: 2025-09-25 15:16 - Updated: 2026-10-01 16:10
Summary
iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\sysupdate\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application’s installation path and executed with SYSTEM privileges, leading to privilege escalation.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "iMonitor EAM",
          "vendor": "iMonitor Software Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "9.63.94"
            }
          ]
        }
      ],
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\\sysupdate\\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application\u2019s installation path and executed with SYSTEM privileges, leading to privilege escalation."
    },
    {
      "lang": "es",
      "value": "iMonitor EAM 9.6394 instala un servicio del sistema (eamusbsrv64.exe) que se ejecuta con privilegios de NT AUTHORITY\\SYSTEM. Este servicio incluye un mecanismo de actualizaci\u00f3n inseguro que carga autom\u00e1ticamente archivos ubicados en el directorio C:\\sysupdate\\ durante el inicio. Debido a que cualquier usuario local puede crear y escribir en este directorio, un atacante puede colocar DLLs o ejecutables maliciosos en \u00e9l. Al reiniciar el servicio, los archivos se mueven a la ruta de instalaci\u00f3n de la aplicaci\u00f3n y se ejecutan con privilegios de SYSTEM, lo que lleva a una escalada de privilegios."
    }
  ],
  "id": "CVE-2025-10541",
  "lastModified": "2026-10-01T16:10:00.257",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-10541",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-09-25T18:26:47.792796Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2025-09-25T15:16:09.270",
  "references": [
    {
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
      "url": "https://r.sec-consult.com/imonitor"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Sep/72"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "url": "https://sec-consult.com/vulnerability-lab/advisory/multiple-vulnerabilities-in-imonitorsoft-eam/"
    }
  ],
  "sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…