Summary
An unauthenticated remote attacker can read out sensitive device information through a incorrectly configured FTP service.
References
▼ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2024-038 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2024-038 | Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:pepperl-fuchs:oit700-f113-b12-cb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "784251D9-E5BC-406B-A0B5-BF01706DBFE7", "versionEndIncluding": "2.11.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:pepperl-fuchs:oit700-f113-b12-cb:-:*:*:*:*:*:*:*", "matchCriteriaId": "25864D9A-0BEA-4427-95D2-FBBEA77A0572", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:pepperl-fuchs:oit500-f113-b12-cb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E24C955B-F5AD-4137-8A89-46B99F119A42", "versionEndIncluding": "2.11.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:pepperl-fuchs:oit500-f113-b12-cb:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A14DBBC-7129-419B-8158-A2AED41D22C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:pepperl-fuchs:oit200-f113-b12-cb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A73CFD0C-620A-44DF-97E5-8938315D533A", "versionEndIncluding": "2.11.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:pepperl-fuchs:oit200-f113-b12-cb:-:*:*:*:*:*:*:*", "matchCriteriaId": "D529BA26-283D-4BCF-BAFD-242105AA9649", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:pepperl-fuchs:oit1500-f113-b12-cb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2407367C-A857-4990-9650-10B61BAD23D0", "versionEndIncluding": "2.11.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:pepperl-fuchs:oit1500-f113-b12-cb:-:*:*:*:*:*:*:*", "matchCriteriaId": "23096D3E-2836-4FA1-9878-831C69EE5AE4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An unauthenticated remote attacker can read out sensitive device information through a incorrectly configured FTP service." }, { "lang": "es", "value": "Un atacante remoto no autenticado puede leer informaci\u00f3n confidencial del dispositivo a trav\u00e9s de un servicio FTP configurado incorrectamente." } ], "id": "CVE-2024-6421", "lastModified": "2025-08-22T07:15:45.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "info@cert.vde.com", "type": "Secondary" } ] }, "published": "2024-07-10T08:15:11.720", "references": [ { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2024-038" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2024-038" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-552" } ], "source": "info@cert.vde.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…