fkie_cve-2024-5557
Vulnerability from fkie_nvd
Published
2024-06-12 17:15
Modified
2024-11-21 09:47
Summary
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD47138-7C8F-4D8B-A669-74395596363D",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A50B62A0-A6FB-4AB4-94A0-D054C5ADB015",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:spacelogic_as-p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1ABCFA-8D7D-4288-AA9F-FF1B177DBB4E",
              "versionEndExcluding": "6.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:spacelogic_as-p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E516910C-FC39-46FA-82A5-0BF3546FDF33",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
    },
    {
      "lang": "es",
      "value": "CWE-532: Existe una vulnerabilidad de inserci\u00f3n de informaci\u00f3n confidencial en el archivo de registro que podr\u00eda causar la exposici\u00f3n de las credenciales SNMP cuando un atacante tiene acceso a los registros del controlador."
    }
  ],
  "id": "CVE-2024-5557",
  "lastModified": "2024-11-21T09:47:55.560",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-12T17:15:51.943",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…