FKIE_CVE-2024-31976

Vulnerability from fkie_nvd - Published: 2024-11-27 17:15 - Updated: 2026-01-26 20:11
Summary
EnGenius EWS356-FIR 1.1.30 and earlier devices allow a remote attacker to execute arbitrary OS commands via the Controller connectivity parameter.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:ews356-fir_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F6449CF-1446-4D0C-A62B-69AC2AD060A6",
              "versionEndIncluding": "1.1.30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:ews356-fir:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC28BDBE-58EC-4956-8F56-957AE225CC37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "EnGenius EWS356-FIR 1.1.30 and earlier devices allow a remote attacker to execute arbitrary OS commands via the Controller connectivity parameter."
    },
    {
      "lang": "es",
      "value": "Los dispositivos EnGenius EWS356-FIR 1.1.30 y anteriores permiten que un atacante remoto ejecute comandos arbitrarios del sistema operativo a trav\u00e9s del par\u00e1metro de conectividad del controlador."
    }
  ],
  "id": "CVE-2024-31976",
  "lastModified": "2026-01-26T20:11:25.677",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-11-27T17:15:10.913",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/actuator/cve/blob/main/Engenius/CVE-2024-31976"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/actuator/cve/tree/main/EnGenius/EWS356-FIT"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…