fkie_cve-2023-29410
Vulnerability from fkie_nvd
Published
2023-04-18 22:15
Modified
2024-11-21 07:57
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated
attacker to gain the same privilege as the application on the server when a malicious payload is
provided over HTTP for the server to execute.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "371B602D-2BB3-41CF-B07B-558B74AEC130", "versionEndExcluding": "1.16", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:-:*:*:*:*:*:*", "matchCriteriaId": "698CF5CB-17DC-405B-9C44-675A80320A65", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:build_004:*:*:*:*:*:*", "matchCriteriaId": "039691CA-D243-4D6D-912A-F130F7F6491C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:insighthome:-:*:*:*:*:*:*:*", "matchCriteriaId": "37CAC057-7F0E-4375-99FE-AEE0EDDEA568", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18E2843D-745F-41D7-8B16-2CC18EC64290", "versionEndExcluding": "1.16", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:-:*:*:*:*:*:*", "matchCriteriaId": "F90B0024-6C86-4E85-AE83-F349D34E7416", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:build_004:*:*:*:*:*:*", "matchCriteriaId": "D81ACD8E-4B04-4BCB-894F-4A5828899C16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:insightfacility:-:*:*:*:*:*:*:*", "matchCriteriaId": "F5011815-3D43-4AA4-9395-31788D06DA10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3524289C-ACF3-424E-9A1E-A777EBFB89F1", "versionEndExcluding": "1.16", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:-:*:*:*:*:*:*", "matchCriteriaId": "62314597-62BC-4531-B5C8-61343262CE9E", "vulnerable": true }, { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:build_004:*:*:*:*:*:*", "matchCriteriaId": "AD27299F-4422-4176-9DFD-86F2E4487366", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:conext_gateway:-:*:*:*:*:*:*:*", "matchCriteriaId": "E013171F-2BFB-4CB2-9C4B-4EB60A40B255", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nA CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated\nattacker to gain the same privilege as the application on the server when a malicious payload is\nprovided over HTTP for the server to execute. \n\n \n\n\n\n" } ], "id": "CVE-2023-29410", "lastModified": "2024-11-21T07:57:00.410", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-18T22:15:08.067", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-02.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…