Summary
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf | Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf | Patch, Third Party Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FAE0D810-0D2A-4158-B1A1-045743098BA9",
"versionEndExcluding": "1.17.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C78D80C0-D12B-41C8-BEA8-576BF2FC5A31",
"versionEndExcluding": "2.3.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"matchCriteriaId": "22874B0C-7AF0-4223-9116-7AF3F6A38A32",
"versionEndExcluding": "3.3.1",
"versionStartIncluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003c V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions \u003c V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003c V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003c V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `\u0027Allow Idp Initiated Authentication\u0027` is enabled."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en el m\u00f3dulo SAML de Mendix (compatible con Mendix 7) (todas las versiones anteriores a V1.17.0), el m\u00f3dulo SAML de Mendix (compatible con Mendix 8) (todas las versiones anteriores a V2.3.0), el m\u00f3dulo SAML de Mendix (compatible con Mendix 9, New Track) (todas las versiones anteriores a V3.3.1), el m\u00f3dulo SAML de Mendix (compatible con Mendix 9, Upgrade Track) (todas las versiones anteriores a V3.3.0). Las versiones afectadas del m\u00f3dulo no protegen suficientemente de la repetici\u00f3n de la captura de paquetes. Esto podr\u00eda permitir a atacantes remotos no autorizados eludir la autenticaci\u00f3n y obtener acceso a la aplicaci\u00f3n. Por razones de compatibilidad, las versiones corregidas a\u00fan contienen este problema, pero s\u00f3lo cuando la opci\u00f3n de configuraci\u00f3n no recomendada y no predeterminada `\u0027Permitir autenticaci\u00f3n iniciada por Idp\u0027` est\u00e1 activada"
}
],
"id": "CVE-2022-37011",
"lastModified": "2024-11-21T07:14:16.827",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-09-13T10:15:10.763",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-294"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…