Summary
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-a\\)_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "427BD8F4-7B5B-44D2-8CB0-975114D52BB6", "versionEndIncluding": "1.7.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-a\\):-:*:*:*:*:*:*:*", "matchCriteriaId": "A13046EC-90A1-4EE2-AA92-3A6BA721FDDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-b\\)_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64F28B16-BCCD-44D4-9EF2-A5138B1DC152", "versionEndIncluding": "2.12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-b\\):-:*:*:*:*:*:*:*", "matchCriteriaId": "E58E9CC3-6865-4E11-91E1-99C0EFD0EE3F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)" }, { "lang": "es", "value": "Una CWE-269: Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiada que podr\u00eda permitir una funcionalidad elevada cuando se adivinan las credenciales. Productos afectados: Acti9 PowerTag Link C (A9XELC10-A) (versiones V1.7.5 y anteriores), Acti9 PowerTag Link C (A9XELC10-B) (versiones V2.12.0 y anteriores)" } ], "id": "CVE-2022-34754", "lastModified": "2024-11-21T07:10:07.283", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-07-13T21:15:08.227", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-269" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…