fkie_cve-2022-32514
Vulnerability from fkie_nvd
Published
2023-01-30 23:15
Modified
2024-11-21 07:06
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7628A67-6DD8-47B7-9112-C130AF0DA9BD",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E9DDB3B-9342-4729-9EE7-703426B9670C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD075DCC-90DA-45A1-ADC9-ADD7D984B2F9",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDCFD29E-C66E-41F4-B578-095C08799994",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7B729EF-ECCC-41E1-BF89-E2EAB013144F",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF623989-1FC8-44D5-9B4B-42CDCF31B824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414788B-B8B5-41A0-8946-433D7A308F4D",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91E6F8C8-BC42-4EA0-B36F-96CCE73B080F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1F807FA-B4A7-4917-80D9-1D9D3AA96516",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0844B578-39C4-413F-9CE9-5DA12A02CE8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B231797-8810-4C77-BD0B-0C8A6FBD8C2B",
              "versionEndExcluding": "1.11.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B48CA89-FC26-45D4-91C3-F2BD74DC3FBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad CWE-287: autenticaci\u00f3n incorrecta que podr\u00eda permitir a un atacante obtener control del dispositivo al iniciar sesi\u00f3n en una p\u00e1gina web. Productos afectados: Controlador de automatizaci\u00f3n de red C-Bus - LSS5500NAC (versiones anteriores a V1.10.0), Wiser para controlador de automatizaci\u00f3n de red C-Bus - LSS5500SHAC (versiones anteriores a V1.10.0), Controlador de automatizaci\u00f3n de red Clipsal C-Bus - 5500NAC (versiones anteriores a V1.10.0), Clipsal Wiser para controlador de automatizaci\u00f3n C-Bus - 5500SHAC (versiones anteriores a V1.10.0), controlador de automatizaci\u00f3n de red SpaceLogic C-Bus - 5500NAC2 (versiones anteriores a V1.10.0), controlador de aplicaciones SpaceLogic C-Bus - 5500AC2 (Versiones anteriores a V1.10.0)"
    }
  ],
  "id": "CVE-2022-32514",
  "lastModified": "2024-11-21T07:06:32.053",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-30T23:15:10.007",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…