fkie_cve-2021-22816
Vulnerability from fkie_nvd
Published
2022-01-28 20:15
Modified
2024-11-21 05:50
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_312e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C1DF5C4-261B-4EB1-866B-6F95F9957D80",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_312e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41D940A7-D3C5-48CF-8A74-C9D850962BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_313e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E30F1191-6287-4E06-AEF2-F6B82CEC42B1",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_313e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "766B36C2-8488-4A26-A5CD-64793B295ABB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_314e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "133F5A6C-E169-4B4D-B0B9-A586382263B3",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_314e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13818C25-4C04-4574-BFC7-705E17C949FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_330e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0076A17D-7D30-460F-8188-4760046D37AC",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_330e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C1BA637-CED5-490E-8786-87792ABADFA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_333e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49F6E99B-F91C-4FE1-ADDE-D2025080D28A",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_333e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E564916-DF7C-4956-ADBF-347A9E921990",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_334e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "368AAD88-AA2A-4DEE-A5FF-CC7AA5285E33",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_334e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB29193B-ABDA-49D0-9EFE-4A1AD177B344",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_337e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "787FF7D4-5B40-4A73-B3A0-F6AA19C73C0C",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_337e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C278FB0-948C-45B4-9D7E-457356319C7D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_350e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE252382-7E9E-4A9D-A038-131027FB41D2",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_350e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "464F5F6F-A56F-4035-BD07-E20B461CD961",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:scadapack_357e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50F227EF-8541-4C2B-B96E-DC0859F5235E",
              "versionEndExcluding": "8.19.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:scadapack_357e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27A03E75-1A51-4392-B78D-844FAF97EA3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior"
    },
    {
      "lang": "es",
      "value": "Una CWE-754: Se presenta una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales que podr\u00eda causar una denegaci\u00f3n de servicio del RTU cuando es recibida una petici\u00f3n especialmente dise\u00f1ada a trav\u00e9s de Modbus, y el RTU est\u00e1 configurado como un servidor Modbus. Productos afectados: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E y 357E RTUs con firmware V8.18.1 y anteriores"
    }
  ],
  "id": "CVE-2021-22816",
  "lastModified": "2024-11-21T05:50:43.777",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-28T20:15:10.303",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-754"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…