fkie_cve-2020-6963
Vulnerability from fkie_nvd
Published
2020-01-24 17:15
Modified
2024-11-21 05:36
Severity ?
Summary
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsma-20-023-01 | Third Party Advisory, US Government Resource | |
nvd@nist.gov | https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf | Product | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsma-20-023-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59", "versionEndIncluding": "4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*", "matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13", "vulnerable": true }, { "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1", "vulnerable": true }, { "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*", "matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610", "versionEndIncluding": "4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*", "matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code." }, { "lang": "es", "value": "En ApexPro Telemetry Server Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Central Station (CSCS) Versiones 1.X, los productos afectados utilizaron Credenciales SMB embebidas, que pueden permitir a un atacante ejecutar c\u00f3digo arbitrario remotamente." } ], "id": "CVE-2020-6963", "lastModified": "2024-11-21T05:36:23.820", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-01-24T17:15:13.220", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01" }, { "source": "nvd@nist.gov", "tags": [ "Product" ], "url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" }, { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…