fkie_cve-2020-28384
Vulnerability from fkie_nvd
Published
2021-01-12 21:15
Modified
2024-11-21 05:22
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf | Vendor Advisory | |
| productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04 | Third Party Advisory, US Government Resource | |
| productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-055/ | Third Party Advisory, VDB Entry | |
| productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-076/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-055/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-076/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge | * | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7AF39DFE-A31B-4324-BB62-0B446ACA04B7",
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"matchCriteriaId": "07440B76-B975-4946-8A97-38C564D240E4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "5F0A748E-BB6F-4604-8024-F50DC0C20EAF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"matchCriteriaId": "F4F37267-6B37-46A4-B9F9-4264BEC922D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"matchCriteriaId": "CB1DC54B-E715-4425-B6B6-900F2CFBCE03",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "2F495722-39BD-4BA1-A643-C7D0BA81CC21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "7B776512-BF3D-4F70-BD58-AFF8E1B03EE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"matchCriteriaId": "99E05299-50FD-4292-9978-8E05C1483FE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"matchCriteriaId": "2447D05B-2634-4895-B7B0-6F7DBB9D2EC2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"matchCriteriaId": "CBBD39F3-790F-4017-A57E-6EFC314F0557",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"matchCriteriaId": "B4387BFA-8A98-433E-9EF7-B29226C195A7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"matchCriteriaId": "9E380F66-C11C-472B-9B71-7CB4AF4FABDC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"matchCriteriaId": "0CF4ACE1-B069-4007-8142-7F90015BBE9D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP12), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP2). Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos proporcionados por el usuario al analizar archivos PAR. Esto podr\u00eda conllevar a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual"
}
],
"id": "CVE-2020-28384",
"lastModified": "2024-11-21T05:22:41.630",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-01-12T21:15:17.917",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…