A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F6EF8A28-8B05-46C2-911F-37AE46E04743",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDD1105D-F909-4383-8490-66891609FDC7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
"matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07DC9E02-9B48-496E-8656-68CFFD399F1B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_pn_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FEC66966-6794-4A83-A425-4BC8911392B8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F007420-6EF7-4ECF-9CBE-BABF39B3EE3F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "581B9FCA-43EC-4BF3-B836-BBD9635EA8C9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn:-:*:*:*:*:*:*:*",
"matchCriteriaId": "40F856D9-7954-4EE1-B5DA-18DFE21069AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0B56C44-3148-4612-9543-9F96DF0142A6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_dp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7593F136-F558-4C3D-8429-5141A621981B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4D67C040-2D94-4872-98F9-B4B08290DD03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315f-2_dp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD7AE84F-1476-4E2C-9E2B-0EDAEFE9EDA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_pn_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "694D542E-3E4F-4B6B-BD87-11EDD6C60527",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315f-2_pn:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50798314-D77E-48C9-B608-0F7A72C88138",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_317f-2_pn_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD47DCD2-068E-43E0-AEF8-71E9941FA816",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317f-2_pn:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2713CAFF-4B49-48DF-A475-02D280927113",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_317f-2_dp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7F1F77B-37E4-4929-BA60-C631067BE843",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317f-2_dp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B30FDCBC-62BC-43AC-BC92-A44D79525215",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_412_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D74D138-6C3A-4E20-9B29-6C9A573A6D32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FD7BD15E-6FB2-489A-A48B-C80021029AE5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_414_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33B29F2B-AC3D-49CE-9573-DCAB9169EA61",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CE95DD6B-F615-47E5-A028-DE6DA7B32B16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_416_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "50F9C422-E902-4890-9CED-3213E696ABE8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D439724-FC4C-4006-BB0C-0DBEA89693A2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_417_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26FB5714-01AF-4E98-84E9-56FF70DBB412",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_417:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BA54AD7F-9D9D-479B-9E67-20378AB8E5A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia de SIMATIC S7-300 CPU (incluyendo las CPU ET200 relacionadas y las variantes SIPLUS) (Todas las versiones), familia SIMATIC S7-400 CPU (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC WinAC RTX (F) 2010 (Todas las versiones), SINUMERIK 840D sl (Todas las versiones). El protocolo de autenticaci\u00f3n entre un cliente y un PLC por medio del puerto 102/tcp (ISO-TSAP) no protege suficientemente la contrase\u00f1a transmitida. Esto podr\u00eda permitir a un atacante que pueda interceptar el tr\u00e1fico de red obtener credenciales del PLC v\u00e1lidas"
}
],
"id": "CVE-2020-15791",
"lastModified": "2024-11-21T05:06:11.270",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-09-09T19:15:20.663",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-522"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…