fkie_cve-2019-6853
Vulnerability from fkie_nvd
Published
2019-11-20 22:15
Modified
2024-11-21 04:47
Severity ?
Summary
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9680_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CABA87DF-4D29-41D5-9C04-FCE822E08548",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9680:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ADB64C97-4C76-4EA1-81BA-BECABB36882F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_5740_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3FCDE6F-3C90-4494-A768-B9556822555E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_5740:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D425EDA6-288C-4F66-B1E8-D47B52C45371",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_5720_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ADAEA00E-C3B6-42B2-823B-5722033E0C46",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_5720:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AD829769-A8A2-4362-83F0-DD8C0C66124C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_bcx4040_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D80F1F9E-89E3-4263-AEA6-555226B412B6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_bcx4040:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CB3D1AD-9BAE-4DA5-B32B-63F1A2FEE30B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_bcx9640_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F2B69F42-8AF8-47AA-ABCC-6FCB2ACF8A2B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_bcx9640:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1A0F10A1-AC1F-425B-90D4-ECFFEFF8A6F4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9900_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "373C69FE-14ED-4D75-9E60-BFE90F111D19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49764811-1299-4612-B19E-5D9BE4005186",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9940_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A7979C28-2D31-4024-B9F9-5BA824D29216",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9940:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7C825C-CAB3-4465-B7B8-380E1A20AC0A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9941_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2FAE3F03-CECB-4B21-987E-B9B7EB1BF3B9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9941:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8AD997D7-5A18-4983-BA8C-D29AA27843C6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9924_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB62B8D7-1157-460B-95A8-DF6F553949CF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9924:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2FB35B6B-69DC-4A8A-AE3E-CA9A6127B080",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9702_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14FDC5C2-695A-4349-B392-82AA8459115B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9702:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F721BC6-0CA1-4431-853D-B2D923A66751",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9200_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0FC56178-69E7-47BC-9965-25EC3CCD7C05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2DE93F39-BF30-42EF-8387-4C060F075D49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server."
},
{
"lang": "es",
"value": "Una CWE-79: Se presenta una vulnerabilidad de Fallo al Preservar la Estructura de la P\u00e1gina Web en Andover Continuum (modelos 9680, 5740 y 5720, bCX4040, bCX9640, 9900, 9940, 9924 y 9702), lo que podr\u00eda permitir un ataque de tipo Cross-site Scripting (XSS) cuando se utiliza el servidor web de productos."
}
],
"id": "CVE-2019-6853",
"lastModified": "2024-11-21T04:47:17.047",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-11-20T22:15:12.107",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…