fkie_cve-2019-0142
Vulnerability from fkie_nvd
Published
2019-11-14 19:15
Modified
2024-11-21 04:16
Severity ?
Summary
Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_x710-tm4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "12B69900-A251-4B7F-900F-076C8C5EE340",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_x710-tm4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41EEFF5E-3C88-43B3-9894-1B0C73DBA06A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_x710-at2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D579875D-1815-4527-94C4-2F7388BC56FD",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_x710-at2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8225E56D-74F1-43FC-8696-2F326A264704",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_xxv710-am2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "811451A0-0961-4C2A-9BD7-D829C4D54B2D",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_xxv710-am2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5C6D2A9E-EE3D-4DEC-948E-58416CD32477",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_xxv710-am1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CA07C275-DC94-4111-8E0B-167DF9658CE7",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_xxv710-am1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA1817F4-978B-4F88-831F-C6259CE20E83",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_x710-bm2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7013E799-8610-49A7-A3AF-B2860E510B58",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_x710-bm2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91940C69-80BB-43F8-81B5-92AAFCF59CE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:ethernet_controller_710-bm1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CF8B188-91E2-4439-B14A-4AD008CBFD5D",
"versionEndExcluding": "1.33.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:ethernet_controller_710-bm1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE34AA9F-CBD1-423B-A457-5FB79081540F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:ethernet_700_series_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BBE4DA9C-61F5-48CF-A995-CD6F48CD4E6B",
"versionEndExcluding": "24.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "Un control de acceso insuficiente en el controlador ilp60x64.sys para Intel\u00ae Ethernet 700 Series Controllers versiones anteriores a la versi\u00f3n 1.33.0.0, puede habilitar a un usuario privilegiado para permitir una escalada de privilegios por medio de un acceso local."
}
],
"id": "CVE-2019-0142",
"lastModified": "2024-11-21T04:16:19.160",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.5,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-11-14T19:15:11.987",
"references": [
{
"source": "secure@intel.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html"
}
],
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…