An issue was discovered on Teltonika RTU950 R_31.04.89 devices. The application allows a user to login without limitation. For every successful login request, the application saves a session. A user can re-login without logging out, causing the application to store the session in memory. Exploitation of this vulnerability will increase memory use and consume free space.
Impacted products
Vendor Product Version
teltonika rut950_firmware r_31.04.89
teltonika rut950 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:teltonika:rut950_firmware:r_31.04.89:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D947C1F-AD43-49AB-97DC-D7540AB3D939",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:teltonika:rut950:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CE17C85-9A69-41FB-AB96-0DCAB72309A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Teltonika RTU950 R_31.04.89 devices. The application allows a user to login without limitation. For every successful login request, the application saves a session. A user can re-login without logging out, causing the application to store the session in memory. Exploitation of this vulnerability will increase memory use and consume free space."
    },
    {
      "lang": "es",
      "value": "Se detecto un problema en los dispositivos Teltonika RTU950 R_31.04.89. La aplicaci\u00f3n permite a un usuario iniciar sesi\u00f3n sin limitaci\u00f3n. Para cada solicitud de inicio de sesi\u00f3n exitosa, la aplicaci\u00f3n guarda una sesi\u00f3n. Un usuario puede volver a iniciar sesi\u00f3n sin cerrar sesi\u00f3n, lo que hace que la aplicaci\u00f3n almacene la sesi\u00f3n en la memoria. La explotaci\u00f3n de esta vulnerabilidad aumentar\u00e1 el uso de la memoria y consumir\u00e1 espacio libre."
    }
  ],
  "id": "CVE-2018-19878",
  "lastModified": "2024-11-21T03:58:44.323",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-19T16:15:10.937",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://www.triadsec.com/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.triadsec.com/CVE-2018-19878.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://www.triadsec.com/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.triadsec.com/CVE-2018-19878.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-416"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…