fkie_cve-2018-12979
Vulnerability from fkie_nvd
Published
2018-07-12 18:29
Modified
2024-11-21 03:46
Severity ?
Summary
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. Weak permissions allow an authenticated user to overwrite critical files by abusing the unrestricted file upload in the WBM.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| wago | 762-3000_firmware | * | |
| wago | 762-3000 | - | |
| wago | 762-3001_firmware | * | |
| wago | 762-3001 | - | |
| wago | 762-3002_firmware | * | |
| wago | 762-3002 | - | |
| wago | 762-3003_firmware | * | |
| wago | 762-3003 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wago:762-3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4997E4E0-070F-4C56-9D7A-E347CE37A454",
"versionEndExcluding": "02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wago:762-3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "483A8AFD-3C9B-4D5C-8E4B-C7700B3E4386",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wago:762-3001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "891BDD51-22CA-4B3D-B5C2-C023AD69DE47",
"versionEndExcluding": "02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wago:762-3001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D66DD54-4209-4680-A193-42520412DCE7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wago:762-3002_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93EC3BF6-BC37-476E-9D91-7B26248F72C9",
"versionEndExcluding": "02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wago:762-3002:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9461E8C-FD0A-4079-9FFA-5023739CE56B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wago:762-3003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0E049663-4A28-4593-A0F3-1A26A4C0AC4A",
"versionEndExcluding": "02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wago:762-3003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AEB28C2E-CA52-491B-9894-F70D44582C91",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. Weak permissions allow an authenticated user to overwrite critical files by abusing the unrestricted file upload in the WBM."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en dispositivos WAGO e!DISPLAY 762-3000 hasta el 762-3003 con firmware en versiones anteriores a la FW 02. Los permisos d\u00e9biles permiten que un usuario autenticado sobrescriba archivos cr\u00edticos abusando de la subida de archivos sin restricci\u00f3n en el WBM."
}
],
"id": "CVE-2018-12979",
"lastModified": "2024-11-21T03:46:10.853",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-07-12T18:29:00.247",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2018/Jul/38"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2018-010"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/45014/"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Mailing List",
"Third Party Advisory"
],
"url": "http://seclists.org/fulldisclosure/2018/Jul/38"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en-us/advisories/vde-2018-010"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/45014/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…