fkie_cve-2017-6023
Vulnerability from fkie_nvd
Published
2017-03-16 04:59
Modified
2025-04-20 01:37
Severity ?
Summary
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cbe_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5962575-2692-4BE9-A2ED-0876266FE32D",
              "versionEndIncluding": "3.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cbeh_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0EF5A0F-70CF-45DA-9059-71897B80CA67",
              "versionEndIncluding": "3.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cm25e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E315B2C5-B4F7-4E40-BB34-8DF025DA6E21",
              "versionEndIncluding": "3.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:fatek:ethernet_module_configuration_tool_cm55e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0F51CA0-E22C-4200-96A5-E726766F9072",
              "versionEndIncluding": "3.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:fatek:plc_ethernet_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "86322EB5-ED30-4FC3-9810-CC11F38246A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en Fatek Automation PLC Ethernet Module. Las herramientas de configuraci\u00f3n del software Ether_cfg afectado en las siguientes versiones de Fatek PLCs: CBEH anteriores a V3.6 Build 170215, CBE versiones anteriores a V3.6 Build 170215, CM55E versiones anteriores a V3.6 Build 170215 y CM25E versiones anteriores a V3.6 Build 170215. Se ha identificado un desbordamiento de b\u00fafer basado en pila, lo que podr\u00eda permitir ejecuci\u00f3n remota de c\u00f3digo o ca\u00edda del dispositivo afectado."
    }
  ],
  "id": "CVE-2017-6023",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 8.5,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-03-16T04:59:00.153",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/96892"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/96892"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…