fkie_cve-2017-12069
Vulnerability from fkie_nvd
Published
2017-08-30 19:29
Modified
2024-11-21 03:08
Severity ?
Summary
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_pcs7 | * | |
siemens | wincc | * | |
ocpfoundation | local_discovery_server | * | |
ocpfoundation | ua_.net | * |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*", matchCriteriaId: "D6D19542-FDC9-4CBC-A75A-370DE4B4C929", versionEndIncluding: "8.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*", matchCriteriaId: "0C4AD3A6-D8F1-4DE0-9B08-25F95753F666", versionEndIncluding: "7.4", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:ocpfoundation:local_discovery_server:*:*:*:*:*:*:*:*", matchCriteriaId: "B5A47D3C-FE15-48DC-9A2B-C2F4A1B74AD6", versionEndIncluding: "1.01.333.0", vulnerable: true, }, { criteria: "cpe:2.3:a:ocpfoundation:ua_.net:*:*:*:*:*:*:*:*", matchCriteriaId: "FE0DC426-A197-41CF-A2D3-C2A959736F80", versionEndIncluding: "2017-03-21", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad XXE en OPC Foundation UA .NET Sample Code antes del 21-03-2017 y Local Discovery Server (LDS) antes de la versión 1.03.367. Los siguientes productos se han visto afectados por esta vulnerabilidad, entre otros: Siemens SIMATIC PCS7 (todas las versiones V8.1 y anteriores), SIMATIC WinCC (todas las versiones anteriores a V7.4 SP1), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14 SP1), SIMATIC NET PC Software y SIMATIC IT Production Suite. Un atacante podría hacer que el sistema acceda a varios recursos escogidos por el atacante mediante el envío de paquetes especialmente manipulados a OPC Discovery Server en el puerto 4840/tcp.", }, ], id: "CVE-2017-12069", lastModified: "2024-11-21T03:08:46.230", metrics: { cvssMetricV2: [ { acInsufInfo: true, baseSeverity: "MEDIUM", cvssData: { accessComplexity: "LOW", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "PARTIAL", baseScore: 6.4, confidentialityImpact: "PARTIAL", integrityImpact: "NONE", vectorString: "AV:N/AC:L/Au:N/C:P/I:N/A:P", version: "2.0", }, exploitabilityScore: 10, impactScore: 4.9, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, source: "nvd@nist.gov", type: "Primary", userInteractionRequired: false, }, ], cvssMetricV30: [ { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 8.2, baseSeverity: "HIGH", confidentialityImpact: "LOW", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H", version: "3.0", }, exploitabilityScore: 3.9, impactScore: 4.2, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2017-08-30T19:29:00.210", references: [ { source: "cve@mitre.org", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/100559", }, { source: "cve@mitre.org", url: "http://www.securitytracker.com/id/1039510", }, { source: "cve@mitre.org", tags: [ "Patch", "Vendor Advisory", ], url: "https://opcfoundation-onlineapplications.org/faq/SecurityBulletins/OPC_Foundation_Security_Bulletin_CVE-2017-12069.pdf", }, { source: "cve@mitre.org", tags: [ "Vendor Advisory", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-535640.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Third Party Advisory", "VDB Entry", ], url: "http://www.securityfocus.com/bid/100559", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "http://www.securitytracker.com/id/1039510", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Patch", "Vendor Advisory", ], url: "https://opcfoundation-onlineapplications.org/faq/SecurityBulletins/OPC_Foundation_Security_Bulletin_CVE-2017-12069.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-535640.pdf", }, ], sourceIdentifier: "cve@mitre.org", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-611", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.