fkie_cve-2015-7918
Vulnerability from fkie_nvd
Published
2015-12-15 05:59
Modified
2025-04-12 10:46
Severity ?
Summary
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | proclima | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*", "matchCriteriaId": "12DFD1A6-BDB8-4864-A3E3-1CBF1609C17B", "versionEndIncluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561." }, { "lang": "es", "value": "M\u00faltiples desbordamientos de buffer en el control F1BookView ActiveX en F1 Bookview en Schneider Electric ProClima en versiones anteriores a 6.2 permite atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s del m\u00e9todo (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx o (7) SetValidationRule, una vulnerabilidad diferente a CVE-2015-8561." } ], "id": "CVE-2015-7918", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2015-12-15T05:59:08.857", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-625" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-630" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-631" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-632" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-633" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-634" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-635" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-625" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-630" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-631" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-632" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-633" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-634" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-635" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…