Summary
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file).
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2010:r2:*:*:*:*:*:*",
              "matchCriteriaId": "0A01B1BA-9515-40F7-A3CF-83D387868470",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2010:r2.1:*:*:*:*:*:*",
              "matchCriteriaId": "EAC05F7C-4F5B-4045-ACFD-1239AEAED3C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2010:r3:*:*:*:*:*:*",
              "matchCriteriaId": "AAD213FA-E444-4DDB-B593-CC79C45D92F2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2010:r3.1:*:*:*:*:*:*",
              "matchCriteriaId": "E4FBC203-019A-4DE0-97ED-F0A4872B4E55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2013:r1:*:*:*:*:*:*",
              "matchCriteriaId": "0733DE5C-D168-4A2B-996F-E2BE671FB4C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2013:r1.1:*:*:*:*:*:*",
              "matchCriteriaId": "9A22FFBF-1EAF-478B-A8F4-5EDBDCAE8F41",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2013:r1.1a:*:*:*:*:*:*",
              "matchCriteriaId": "64BF21B8-F98E-46C5-A1AC-FE7DBD45D80F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2013:r1.2:*:*:*:*:*:*",
              "matchCriteriaId": "A2115F6A-1689-4121-99FA-5821C78BA394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:aveva:clearscada:2013:r2:*:*:*:*:*:*",
              "matchCriteriaId": "D2F240E9-4C6F-4257-9F20-456B736569CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file)."
    },
    {
      "lang": "es",
      "value": "El controlador PLC en ServerMain.exe en el componente Kepware KepServerEX 4 en Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955 y 2013 R2 build 74.5094 permite a atacantes remotos causar una denegaci\u00f3n de servicio (ca\u00edda de aplicaci\u00f3n) a trav\u00e9s de un archivo OPF manipulado (tambi\u00e9n conocido como archivo de proyecto)."
    }
  ],
  "id": "CVE-2014-0779",
  "lastModified": "2025-09-24T22:15:35.147",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary",
        "userInteractionRequired": true
      },
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2014-03-14T10:55:05.803",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-024-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-072-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-024-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-072-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…