CVE-2026-5397 (GCVE-0-2026-5397)

Vulnerability from cvelistv5 – Published: 2026-04-15 04:11 – Updated: 2026-04-15 16:13
VLAI?
Title
Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application
Summary
It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges. If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.
CWE
  • CWE-427 - Uncontrolled Search Path Element
Assigner
Impacted products
Date Public ?
2026-04-15 04:08
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5397",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-15T13:46:38.260570Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-15T16:13:26.313Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "PowerAttendant Standard Edition",
          "vendor": "OMRON SOCIAL SOLUTIONS CO., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2 or lower",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2026-04-15T04:08:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eIt has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u0026nbsp;is then executed with administrator privileges.\u003c/div\u003eIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u0026nbsp;may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup."
            }
          ],
          "value": "It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u00a0is then executed with administrator privileges.\n\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u00a0may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-471",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-471 Search Order Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427 Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-15T04:11:29.716Z",
        "orgId": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
        "shortName": "OMRON"
      },
      "references": [
        {
          "url": "https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf"
        },
        {
          "url": "https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bba440f9-ef23-4224-aa62-7ac0935d18d1",
    "assignerShortName": "OMRON",
    "cveId": "CVE-2026-5397",
    "datePublished": "2026-04-15T04:11:29.716Z",
    "dateReserved": "2026-04-02T00:17:38.524Z",
    "dateUpdated": "2026-04-15T16:13:26.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-5397",
      "date": "2026-04-16",
      "epss": "0.00011",
      "percentile": "0.01225"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-5397\",\"sourceIdentifier\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"published\":\"2026-04-15T05:16:45.740\",\"lastModified\":\"2026-04-15T05:16:45.740\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u00a0is then executed with administrator privileges.\\n\\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u00a0may be executed by exploiting the product\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.1,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"references\":[{\"url\":\"https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf\",\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\"},{\"url\":\"https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf\",\"source\":\"bba440f9-ef23-4224-aa62-7ac0935d18d1\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-5397\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-15T13:46:38.260570Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-15T13:46:44.852Z\"}}], \"cna\": {\"title\": \"Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-471\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-471 Search Order Hijacking\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"OMRON SOCIAL SOLUTIONS CO., Ltd.\", \"product\": \"PowerAttendant Standard Edition\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.1.2 or lower\", \"versionType\": \"custom\"}], \"platforms\": [\"Windows\"], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-04-15T04:08:00.000Z\", \"references\": [{\"url\": \"https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf\"}, {\"url\": \"https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\\u00a0is then executed with administrator privileges.\\n\\nIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\\u00a0may be executed by exploiting the product\\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003eIt has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that\u0026nbsp;is then executed with administrator privileges.\u003c/div\u003eIf a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL\u0026nbsp;may be executed by exploiting the product\\u2019s behavior of loading missing DLLs from the same directory as the executable during service startup.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-427\", \"description\": \"CWE-427 Uncontrolled Search Path Element\"}]}], \"providerMetadata\": {\"orgId\": \"bba440f9-ef23-4224-aa62-7ac0935d18d1\", \"shortName\": \"OMRON\", \"dateUpdated\": \"2026-04-15T04:11:29.716Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-5397\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-15T16:13:26.313Z\", \"dateReserved\": \"2026-04-02T00:17:38.524Z\", \"assignerOrgId\": \"bba440f9-ef23-4224-aa62-7ac0935d18d1\", \"datePublished\": \"2026-04-15T04:11:29.716Z\", \"assignerShortName\": \"OMRON\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…