CVE-2025-27211 (GCVE-0-2025-27211)
Vulnerability from cvelistv5
Published
2025-08-04 22:12
Modified
2025-08-05 13:26
Severity ?
VLAI Severity ?
EPSS score ?
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Ubiquiti Inc | EdgeMAX EdgeSwitch |
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-27211", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-08-05T13:22:10.644805Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-05T13:26:05.845Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "affected", "product": "EdgeMAX EdgeSwitch", "vendor": "Ubiquiti Inc", "versions": [ { "lessThan": "1.11.0", "status": "unaffected", "version": "1.11.0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network." } ], "providerMetadata": { "dateUpdated": "2025-08-04T22:12:18.821Z", "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1", "shortName": "hackerone" }, "references": [ { "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961" } ] } }, "cveMetadata": { "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1", "assignerShortName": "hackerone", "cveId": "CVE-2025-27211", "datePublished": "2025-08-04T22:12:18.821Z", "dateReserved": "2025-02-20T01:00:01.799Z", "dateUpdated": "2025-08-05T13:26:05.845Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-27211\",\"sourceIdentifier\":\"support@hackerone.com\",\"published\":\"2025-08-04T23:15:27.403\",\"lastModified\":\"2025-08-05T14:34:17.327\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\"},{\"lang\":\"es\",\"value\":\"Una validaci\u00f3n de entrada incorrecta en EdgeMAX EdgeSwitch (versi\u00f3n 1.10.4 y anteriores) podr\u00eda permitir una inyecci\u00f3n de comandos por parte de un actor malicioso con acceso a la red adyacente de EdgeSwitch.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"},{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961\",\"source\":\"support@hackerone.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-27211\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-05T13:22:10.644805Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-05T13:24:18.757Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Ubiquiti Inc\", \"product\": \"EdgeMAX EdgeSwitch\", \"versions\": [{\"status\": \"unaffected\", \"version\": \"1.11.0\", \"lessThan\": \"1.11.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\"}], \"providerMetadata\": {\"orgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"shortName\": \"hackerone\", \"dateUpdated\": \"2025-08-04T22:12:18.821Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-27211\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-05T13:26:05.845Z\", \"dateReserved\": \"2025-02-20T01:00:01.799Z\", \"assignerOrgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"datePublished\": \"2025-08-04T22:12:18.821Z\", \"assignerShortName\": \"hackerone\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…