Summary
Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access backup data from applications. User interaction is required for triggering this vulnerability.
References
| URL | Tags | ||
|---|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Samsung Mobile | Smart Switch |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-21060",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-10T17:06:20.544579Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-10T17:08:02.644Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Smart Switch",
"vendor": "Samsung Mobile",
"versions": [
{
"status": "unaffected",
"version": "3.7.67.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access backup data from applications. User interaction is required for triggering this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-10T06:33:18.848Z",
"orgId": "3af57064-a867-422c-b2ad-40307b65c458",
"shortName": "SamsungMobile"
},
"references": [
{
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2025\u0026month=10"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
"assignerShortName": "SamsungMobile",
"cveId": "CVE-2025-21060",
"datePublished": "2025-10-10T06:33:18.848Z",
"dateReserved": "2024-11-06T02:30:14.892Z",
"dateUpdated": "2025-10-10T17:08:02.644Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-21060\",\"sourceIdentifier\":\"mobile.security@samsung.com\",\"published\":\"2025-10-10T07:15:41.973\",\"lastModified\":\"2025-10-28T15:41:26.127\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access backup data from applications. User interaction is required for triggering this vulnerability.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"mobile.security@samsung.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:samsung:smart_switch:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.7.67.2\",\"matchCriteriaId\":\"5D27227C-CA20-479D-9B1F-F0591FEFA6AC\"}]}]}],\"references\":[{\"url\":\"https://security.samsungmobile.com/serviceWeb.smsb?year=2025\u0026month=10\",\"source\":\"mobile.security@samsung.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-21060\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-10T17:06:20.544579Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-10T17:07:48.595Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Samsung Mobile\", \"product\": \"Smart Switch\", \"versions\": [{\"status\": \"unaffected\", \"version\": \"3.7.67.2\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://security.samsungmobile.com/serviceWeb.smsb?year=2025\u0026month=10\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access backup data from applications. User interaction is required for triggering this vulnerability.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-312 Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"3af57064-a867-422c-b2ad-40307b65c458\", \"shortName\": \"SamsungMobile\", \"dateUpdated\": \"2025-10-10T06:33:18.848Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-21060\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-10T17:08:02.644Z\", \"dateReserved\": \"2024-11-06T02:30:14.892Z\", \"assignerOrgId\": \"3af57064-a867-422c-b2ad-40307b65c458\", \"datePublished\": \"2025-10-10T06:33:18.848Z\", \"assignerShortName\": \"SamsungMobile\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…