CVE-2025-12896 (GCVE-0-2025-12896)
Vulnerability from cvelistv5
Published
2025-11-07 20:24
Modified
2025-11-07 20:40
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.
Impacted products
Vendor Product Version
Solidigm™ D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336 Version: All FW prior to ACV10360
Version: All FW prior to JCV10501
Version: All FW prior to 9CV10490
Version: All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)
Version: All FW prior to 5CV10326
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12896",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-07T20:39:53.655558Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-07T20:40:07.108Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336",
          "vendor": "Solidigm\u2122",
          "versions": [
            {
              "status": "affected",
              "version": "All FW prior to ACV10360"
            },
            {
              "status": "affected",
              "version": "All FW prior to JCV10501"
            },
            {
              "status": "affected",
              "version": "All FW prior to 9CV10490"
            },
            {
              "status": "affected",
              "version": "All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)"
            },
            {
              "status": "affected",
              "version": "All FW prior to 5CV10326"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-07T20:24:11.186Z",
        "orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
        "shortName": "Solidigm"
      },
      "references": [
        {
          "url": "https://www.solidigm.com/support-page/support-security.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
    "assignerShortName": "Solidigm",
    "cveId": "CVE-2025-12896",
    "datePublished": "2025-11-07T20:24:11.186Z",
    "dateReserved": "2025-11-07T18:56:03.627Z",
    "dateUpdated": "2025-11-07T20:40:07.108Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-12896\",\"sourceIdentifier\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"published\":\"2025-11-07T21:15:40.750\",\"lastModified\":\"2025-11-07T21:15:40.750\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-307\"}]}],\"references\":[{\"url\":\"https://www.solidigm.com/support-page/support-security.html\",\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12896\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-11-07T20:39:53.655558Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-11-07T20:39:58.336Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-114\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-114 Authentication Abuse\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Solidigm\\u2122\", \"product\": \"D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336\", \"versions\": [{\"status\": \"affected\", \"version\": \"All FW prior to ACV10360\"}, {\"status\": \"affected\", \"version\": \"All FW prior to JCV10501\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 9CV10490\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 5CV10326\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.solidigm.com/support-page/support-security.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-307\", \"description\": \"CWE-307 Improper Restriction of Excessive Authentication Attempts\"}]}], \"providerMetadata\": {\"orgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"shortName\": \"Solidigm\", \"dateUpdated\": \"2025-11-07T20:24:11.186Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-12896\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-07T20:40:07.108Z\", \"dateReserved\": \"2025-11-07T18:56:03.627Z\", \"assignerOrgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"datePublished\": \"2025-11-07T20:24:11.186Z\", \"assignerShortName\": \"Solidigm\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…