2025-11-07 21:27
Modified
2025-11-07 21:27
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Summary
Potential Denial of Service issue in all supported versions of Revenera InstallShield version 2025 R1, 2024 R2, 2023 R2, and prior. When e.g., a local administrator performs an uninstall, a symlink may get followed on removal of a user writeable configuration directory and induce a Denial of Service as a result. The issue is resolved through the hotfixes InstallShield2025R1-CVE-2025-12418-SecurityPatch, InstallShield2024R2-CVE-2025-12418-SecurityPatch, and InstallShield2023R2-CVE-2025-12418-SecurityPatch.
Impacted products
Vendor Product Version
Revenera InstallShield Version: 2023.R1    2023.R2
Version: 2024.R1    2024.R2
Version: 2025.R1   < InstallShield2025R1-CVE-2025-12418-SecurityPatch
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "InstallShield",
          "vendor": "Revenera",
          "versions": [
            {
              "changes": [
                {
                  "at": "InstallShield2023R2-CVE-2025-12418-SecurityPatch",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "2023.R2",
              "status": "affected",
              "version": "2023.R1",
              "versionType": "semver"
            },
            {
              "changes": [
                {
                  "at": "InstallShield2024R2-CVE-2025-12418-SecurityPatch",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "2024.R2",
              "status": "affected",
              "version": "2024.R1",
              "versionType": "semver"
            },
            {
              "lessThan": "InstallShield2025R1-CVE-2025-12418-SecurityPatch",
              "status": "affected",
              "version": "2025.R1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:revenera:installshield:*:*:windows:*:*:*:*:*",
                  "versionEndIncluding": "2023.r2",
                  "versionStartIncluding": "2023.r1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:revenera:installshield:*:*:windows:*:*:*:*:*",
                  "versionEndIncluding": "2024.r2",
                  "versionStartIncluding": "2024.r1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:revenera:installshield:*:*:windows:*:*:*:*:*",
                  "versionEndExcluding": "installshield2025r1-cve-2025-12418-securitypatch",
                  "versionStartIncluding": "2025.r1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Potential Denial of Service issue in all supported versions of Revenera InstallShield version 2025 R1, 2024 R2, 2023 R2, and prior. When e.g., a local administrator performs an uninstall, a symlink may get followed on removal of a user writeable configuration directory and induce a Denial of Service as a result. The issue is resolved through the hotfixes\u0026nbsp;InstallShield2025R1-CVE-2025-12418-SecurityPatch, \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInstallShield2024R2-CVE-2025-12418-SecurityPatch, and\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInstallShield2023R2-CVE-2025-12418-SecurityPatch.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Potential Denial of Service issue in all supported versions of Revenera InstallShield version 2025 R1, 2024 R2, 2023 R2, and prior. When e.g., a local administrator performs an uninstall, a symlink may get followed on removal of a user writeable configuration directory and induce a Denial of Service as a result. The issue is resolved through the hotfixes\u00a0InstallShield2025R1-CVE-2025-12418-SecurityPatch, InstallShield2024R2-CVE-2025-12418-SecurityPatch, and\u00a0InstallShield2023R2-CVE-2025-12418-SecurityPatch."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-132",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-132 Symlink Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-07T21:27:04.650Z",
        "orgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
        "shortName": "flexera"
      },
      "references": [
        {
          "url": "https://community.revenera.com/s/article/CVE-2025-12418-Potential-Unintended-File-Deletion-Issue-Caused-by-InstallShield-Suite-Uninstallation-Process"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Apply hotfixes\u0026nbsp;InstallShield2025R1-CVE-2025-12418-SecurityPatch,\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInstallShield2024R2-CVE-2025-12418-SecurityPatch, or\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInstallShield2023R2-CVE-2025-12418-SecurityPatch.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Apply hotfixes\u00a0InstallShield2025R1-CVE-2025-12418-SecurityPatch,\u00a0InstallShield2024R2-CVE-2025-12418-SecurityPatch, or\u00a0InstallShield2023R2-CVE-2025-12418-SecurityPatch."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Potential Denial of Service in Supported Versions of Revenera InstallShield",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
    "assignerShortName": "flexera",
    "cveId": "CVE-2025-12418",
    "datePublished": "2025-11-07T21:27:04.650Z",
    "dateReserved": "2025-10-28T16:09:55.027Z",
    "dateUpdated": "2025-11-07T21:27:04.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-12418\",\"sourceIdentifier\":\"PSIRT-CNA@flexerasoftware.com\",\"published\":\"2025-11-07T22:15:38.843\",\"lastModified\":\"2025-11-07T22:15:38.843\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Potential Denial of Service issue in all supported versions of Revenera InstallShield version 2025 R1, 2024 R2, 2023 R2, and prior. When e.g., a local administrator performs an uninstall, a symlink may get followed on removal of a user writeable configuration directory and induce a Denial of Service as a result. The issue is resolved through the hotfixes\u00a0InstallShield2025R1-CVE-2025-12418-SecurityPatch, InstallShield2024R2-CVE-2025-12418-SecurityPatch, and\u00a0InstallShield2023R2-CVE-2025-12418-SecurityPatch.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT-CNA@flexerasoftware.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"PSIRT-CNA@flexerasoftware.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-59\"}]}],\"references\":[{\"url\":\"https://community.revenera.com/s/article/CVE-2025-12418-Potential-Unintended-File-Deletion-Issue-Caused-by-InstallShield-Suite-Uninstallation-Process\",\"source\":\"PSIRT-CNA@flexerasoftware.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…