Rockwell Automation PowerFlex 6000T CIP Security denial-of-service Vulnerability
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Rockwell Automation | Drives - PowerFlex 6000T |
Version: 8.001 Version: 8.002 Version: 9.001 |
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:rockwellautomation:powerflex_600t:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "powerflex_600t", "vendor": "rockwellautomation", "versions": [ { "status": "affected", "version": "8.001" }, { "status": "affected", "version": "8.002" }, { "status": "affected", "version": "9.001" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-9124", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T18:57:04.611704Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-21T16:55:08.532Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Drives - PowerFlex 6000T", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "8.001" }, { "status": "affected", "version": "8.002" }, { "status": "affected", "version": "9.001" } ] } ], "datePublic": "2024-10-08T16:16:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 600T. If the device is overloaded with requests, it will become unavailable. The device may require a power cycle to recover it if it does not re-establish a connection after it stops receiving requests. \u003c/span\u003e" } ], "value": "A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 600T. If the device is overloaded with requests, it will become unavailable. The device may require a power cycle to recover it if it does not re-establish a connection after it stops receiving requests." } ], "impacts": [ { "capecId": "CAPEC-26", "descriptions": [ { "lang": "en", "value": "CAPEC-26 Leveraging Race Conditions" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 8.2, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-754", "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T16:23:09.331Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1705.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cul\u003e\u003cli\u003eUpdate to v10.001 or later\u003c/li\u003e\u003c/ul\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds \u003c/b\u003e\u003cbr\u003eCustomers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u202f\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "* Update to v10.001 or later\n\n\n\n\nMitigations and Workarounds \nCustomers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u202f\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "source": { "advisory": "SD1705", "discovery": "INTERNAL" }, "title": "Rockwell Automation PowerFlex 6000T CIP Security denial-of-service Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-9124", "datePublished": "2024-10-08T16:23:09.331Z", "dateReserved": "2024-09-23T20:07:02.816Z", "dateUpdated": "2024-11-21T16:55:08.532Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-9124\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-10-08T17:15:56.390\",\"lastModified\":\"2024-11-21T17:15:26.820\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 600T. If the device is overloaded with requests, it will become unavailable. The device may require a power cycle to recover it if it does not re-establish a connection after it stops receiving requests.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de denegaci\u00f3n de servicio en el PowerFlex\u00ae 600T de Rockwell Automation. Si el dispositivo se sobrecarga con solicitudes, dejar\u00e1 de estar disponible. Es posible que sea necesario apagar y encender el dispositivo para recuperarlo si no restablece una conexi\u00f3n despu\u00e9s de dejar de recibir solicitudes.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1705.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.