cve-2024-48967
Vulnerability from cvelistv5
Published
2024-11-14 21:40
Modified
2024-11-15 14:28
Severity ?
EPSS score ?
Summary
The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Baxter | Life2000 Ventilation System |
Version: 06.08.00.00 and prior |
{ containers: { adp: [ { affected: [ { cpes: [ "cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*", ], defaultStatus: "unknown", product: "life2000_ventilator_firmware", vendor: "baxter", versions: [ { lessThan: "6.08.00.00", status: "affected", version: "0", versionType: "custom", }, ], }, ], metrics: [ { other: { content: { id: "CVE-2024-48967", options: [ { Exploitation: "none", }, { Automatable: "yes", }, { "Technical Impact": "total", }, ], role: "CISA Coordinator", timestamp: "2024-11-15T14:28:10.676566Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-11-15T14:28:13.605Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unaffected", product: "Life2000 Ventilation System", vendor: "Baxter", versions: [ { status: "affected", version: "06.08.00.00 and prior", }, ], }, ], datePublic: "2024-11-14T21:38:00.000Z", descriptions: [ { lang: "en", supportingMedia: [ { base64: false, type: "text/html", value: "The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.", }, ], value: "The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.", }, ], impacts: [ { capecId: "CAPEC-117", descriptions: [ { lang: "en", value: "CAPEC-117 Interception", }, ], }, { capecId: "CAPEC-441", descriptions: [ { lang: "en", value: "CAPEC-441 Malicious Logic Insertion", }, ], }, ], metrics: [ { cvssV3_1: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 10, baseSeverity: "CRITICAL", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "CHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", version: "3.1", }, format: "CVSS", scenarios: [ { lang: "en", value: "GENERAL", }, ], }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-778", description: "CWE-778: Insufficient Logging", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-11-14T21:52:23.702Z", orgId: "dba971b9-eb30-4121-91e1-3b45611354aa", shortName: "Baxter", }, references: [ { url: "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01", }, ], source: { discovery: "UNKNOWN", }, title: "Life2000 ventilator and Service PC lack sufficient audit logging capabilities", x_generator: { engine: "Vulnogram 0.2.0", }, }, }, cveMetadata: { assignerOrgId: "dba971b9-eb30-4121-91e1-3b45611354aa", assignerShortName: "Baxter", cveId: "CVE-2024-48967", datePublished: "2024-11-14T21:40:44.904Z", dateReserved: "2024-10-10T19:24:34.436Z", dateUpdated: "2024-11-15T14:28:13.605Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2024-48967\",\"sourceIdentifier\":\"productsecurity@baxter.com\",\"published\":\"2024-11-14T22:15:17.927\",\"lastModified\":\"2024-11-15T13:58:08.913\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.\"},{\"lang\":\"es\",\"value\":\"El respirador y la PC de servicio carecen de capacidades de registro de auditoría suficientes para permitir la detección de actividad maliciosa y el posterior examen forense. Un atacante con acceso al respirador o a la PC de servicio podría, sin ser detectado, realizar cambios no autorizados en la configuración del respirador que resulten en la divulgación no autorizada de información o tengan impactos no deseados en el rendimiento del dispositivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productsecurity@baxter.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"productsecurity@baxter.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-778\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01\",\"source\":\"productsecurity@baxter.com\"}]}}", vulnrichment: { containers: "{\"cna\": {\"title\": \"Life2000 ventilator and Service PC lack sufficient audit logging capabilities\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-117\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-117 Interception\"}]}, {\"capecId\": \"CAPEC-441\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-441 Malicious Logic Insertion\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 10, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Baxter\", \"product\": \"Life2000 Ventilation System\", \"versions\": [{\"status\": \"affected\", \"version\": \"06.08.00.00 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-11-14T21:38:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make unauthorized changes to ventilator settings that result in unauthorized disclosure of information and/or have unintended impacts on device performance.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-778\", \"description\": \"CWE-778: Insufficient Logging\"}]}], \"providerMetadata\": {\"orgId\": \"dba971b9-eb30-4121-91e1-3b45611354aa\", \"shortName\": \"Baxter\", \"dateUpdated\": \"2024-11-14T21:52:23.702Z\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-48967\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-15T14:28:10.676566Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"baxter\", \"product\": \"life2000_ventilator_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.08.00.00\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2024-11-15T14:27:46.856Z\"}}]}", cveMetadata: "{\"cveId\": \"CVE-2024-48967\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-14T21:52:23.702Z\", \"dateReserved\": \"2024-10-10T19:24:34.436Z\", \"assignerOrgId\": \"dba971b9-eb30-4121-91e1-3b45611354aa\", \"datePublished\": \"2024-11-14T21:40:44.904Z\", \"assignerShortName\": \"Baxter\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.