CVE-2024-33618 (GCVE-0-2024-33618)
Vulnerability from cvelistv5 – Published: 2026-04-15 09:51 – Updated: 2026-04-15 13:09
VLAI?
Summary
Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1
allows attackers to consume excessive amounts of disk space via network interface.
Severity ?
7.5 (High)
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | BVMS |
Affected:
6.0 , ≤ 12.0.1
(custom)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33618",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-15T13:09:08.201665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T13:09:13.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1 \r\nallows attackers to consume excessive amounts of disk space via network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T09:51:52.722Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2024-33618",
"datePublished": "2026-04-15T09:51:52.722Z",
"dateReserved": "2024-06-17T09:19:04.535Z",
"dateUpdated": "2026-04-15T13:09:13.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-33618",
"date": "2026-04-16",
"epss": "0.0004",
"percentile": "0.12006"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-33618\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2026-04-15T10:16:37.120\",\"lastModified\":\"2026-04-15T10:16:37.120\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1 \\r\\nallows attackers to consume excessive amounts of disk space via network interface.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html\",\"source\":\"psirt@bosch.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-33618\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-15T13:09:08.201665Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-15T13:09:10.441Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Bosch\", \"product\": \"BVMS\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"BVMS Viewer\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"Bosch DIVAR IP all-in-one 7000 R3\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"Bosch DIVAR IP 7000 R2\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"Bosch DIVAR IP all-in-one 5000\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"Bosch DIVAR IP all-in-one 7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"DIVAR IP all-in-one 4000\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.1.1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}, {\"vendor\": \"Bosch\", \"product\": \"DIVAR IP all-in-one 6000\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.1.1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"12.0.1\"}]}], \"references\": [{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html\", \"name\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html\", \"tags\": [\"vendor-advisory\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1 \\r\\nallows attackers to consume excessive amounts of disk space via network interface.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"cweId\": \"CWE-400\", \"description\": \"CWE-400 Uncontrolled Resource Consumption\"}]}], \"providerMetadata\": {\"orgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"shortName\": \"bosch\", \"dateUpdated\": \"2026-04-15T09:51:52.722Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-33618\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-15T13:09:13.468Z\", \"dateReserved\": \"2024-06-17T09:19:04.535Z\", \"assignerOrgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"datePublished\": \"2026-04-15T09:51:52.722Z\", \"assignerShortName\": \"bosch\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…