cve-2024-10386
Vulnerability from cvelistv5
Published
2024-10-25 17:04
Modified
2024-10-25 20:17
Summary
Rockwell Automation FactoryTalk ThinManager Authentication Vulnerability
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "thinmanager",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThanOrEqual": "11.2.9",
                "status": "affected",
                "version": "11.2.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.0.7",
                "status": "affected",
                "version": "12.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.1.8",
                "status": "affected",
                "version": "12.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.0.5",
                "status": "affected",
                "version": "13.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.1.3",
                "status": "affected",
                "version": "13.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.2.2",
                "status": "affected",
                "version": "13.2.0",
                "versionType": "custom"
              },
              {
                "status": "affected",
                "version": "14.0.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10386",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:14:39.256573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:17:55.566Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk ThinManager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "11.2.0-11.2.9"
            },
            {
              "status": "affected",
              "version": "12.0.0-12.0.7"
            },
            {
              "status": "affected",
              "version": "12.1.0-12.1.8"
            },
            {
              "status": "affected",
              "version": "13.0.0-13.0.5"
            },
            {
              "status": "affected",
              "version": "13.1.0-13.1.3"
            },
            {
              "status": "affected",
              "version": "13.2.0-13.2.2"
            },
            {
              "status": "affected",
              "version": "14.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Tenable Network Security"
        }
      ],
      "datePublic": "2024-10-25T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-10386 IMPACT\u003c/u\u003e\u003c/b\u003e\u003cu\u003e\u003c/u\u003e\u003c/p\u003e\n\n\u003cp\u003eAn authentication\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device, potentially\nresulting in database manipulation.\u003c/p\u003e"
            }
          ],
          "value": "CVE-2024-10386 IMPACT\n\n\n\nAn authentication\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device, potentially\nresulting in database manipulation."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-153",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-153 Input Data Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-25T17:04:34.000Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: var(--wht);\"\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e11.2.10\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.0.8\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.1.9\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e13.0.6\u0026nbsp;\u003c/p\u003e\n\n\n\n\u003cp\u003e13.1.4\u0026nbsp;\u003c/p\u003e\n\n\n\n\u003cp\u003e13.2.3\u0026nbsp;\u003c/p\u003e\n\n\n\n\u003cp\u003e14.0.1\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nIf able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\n\n\n11.2.10\n\n\n\n\n\n12.0.8\n\n\n\n\n\n12.1.9\n\n\n\n\n\n13.0.6\u00a0\n\n\n\n\n\n13.1.4\u00a0\n\n\n\n\n\n13.2.3\u00a0\n\n\n\n\n\n14.0.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk ThinManager Authentication Vulnerability",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best\npractices\u003c/a\u003e to\nminimize the risk of the vulnerability.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nIf able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested security best\npractices to\nminimize the risk of the vulnerability."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-10386",
    "datePublished": "2024-10-25T17:04:34.000Z",
    "dateReserved": "2024-10-25T12:38:28.748Z",
    "dateUpdated": "2024-10-25T20:17:55.566Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-10386\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-10-25T17:15:03.987\",\"lastModified\":\"2024-11-05T20:07:59.487\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CVE-2024-10386 IMPACT\\n\\n\\n\\nAn authentication\\nvulnerability exists in the affected product. The vulnerability could allow a\\nthreat actor with network access to send crafted messages to the device, potentially\\nresulting in database manipulation.\"},{\"lang\":\"es\",\"value\":\"CVE-2024-10386 IMPACTO Existe una vulnerabilidad de autenticaci\u00f3n en el producto afectado. La vulnerabilidad podr\u00eda permitir que un actor de amenazas con acceso a la red env\u00ede mensajes manipulados al dispositivo, lo que podr\u00eda provocar la manipulaci\u00f3n de la base de datos.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.2.0\",\"versionEndExcluding\":\"11.2.10\",\"matchCriteriaId\":\"AC6CF373-34C9-43AC-B210-2E7C31CEAEFA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.0\",\"versionEndExcluding\":\"12.0.8\",\"matchCriteriaId\":\"9EAE9FF9-28B3-4490-8358-A3636FFDC9C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.1.0\",\"versionEndExcluding\":\"12.1.9\",\"matchCriteriaId\":\"667ACE9F-6074-4300-A90A-5C6F8A06B76A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.0.0\",\"versionEndExcluding\":\"13.0.6\",\"matchCriteriaId\":\"C56E6406-256A-4774-9FDD-E72625D4B1AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.1.0\",\"versionEndExcluding\":\"13.1.4\",\"matchCriteriaId\":\"EBC9C4F3-88C5-4FDF-873C-19EB726EFC26\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.2.3\",\"matchCriteriaId\":\"5CB3EC6B-AFAF-4D59-98C6-9BA8E817604B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:thinmanager:14.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48214ABF-9E29-4422-A0E6-6AF4AE199D51\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.