CVE-2023-6094 (GCVE-0-2023-6094)
Vulnerability from cvelistv5
Published
2023-12-31 09:57
Modified
2024-08-26 20:21
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Summary
A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.204Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6094",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-26T20:21:02.392909Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-26T20:21:09.811Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117: Interception"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-04T15:08:08.275Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Since Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \n\nMoxa recommends users to implement the following mitigations if necessary: \n\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2023-6094",
    "datePublished": "2023-12-31T09:57:27.448Z",
    "dateReserved": "2023-11-13T02:17:37.177Z",
    "dateUpdated": "2024-08-26T20:21:09.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-6094\",\"sourceIdentifier\":\"psirt@moxa.com\",\"published\":\"2023-12-31T10:15:08.787\",\"lastModified\":\"2024-11-21T08:43:07.383\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las versiones de firmware de la serie OnCell G3150A-LTE v1.3 y anteriores. La vulnerabilidad se debe a la falta de protecci\u00f3n de la informaci\u00f3n confidencial durante la transmisi\u00f3n. Un atacante que escuche el tr\u00e1fico entre el navegador web y el servidor puede obtener informaci\u00f3n confidencial. Este tipo de ataque podr\u00eda ejecutarse para recopilar informaci\u00f3n confidencial o para facilitar un ataque posterior contra el objetivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@moxa.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"psirt@moxa.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moxa:oncell_g3150a-lte_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3\",\"matchCriteriaId\":\"4F758200-C50E-4456-AAA9-870206050FAE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moxa:oncell_g3150a-lte:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4BDE004-9181-4030-AEB3-594B9B478879\"}]}]}],\"references\":[{\"url\":\"https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement\",\"source\":\"psirt@moxa.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T08:21:17.204Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-6094\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-26T20:21:02.392909Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-26T20:21:06.362Z\"}}], \"cna\": {\"title\": \"OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-117\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-117: Interception\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Moxa\", \"product\": \"OnCell G3150A-LTE Series\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.3\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement\", \"tags\": [\"vendor-advisory\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Since Oncell G3150A-LTE has been phased out, we don\\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \\n\\nMoxa recommends users to implement the following mitigations if necessary: \\n\\n  *  Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \\n\\n\\n  *  Place control system networks and remote devices behind firewalls, isolating them from business networks. \\n\\n\\n  *  When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eA vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-319\", \"description\": \"CWE-319: Cleartext Transmission of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"2e0a0ee2-d866-482a-9f5e-ac03d156dbaa\", \"shortName\": \"Moxa\", \"dateUpdated\": \"2024-01-04T15:08:08.275Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-6094\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-26T20:21:09.811Z\", \"dateReserved\": \"2023-11-13T02:17:37.177Z\", \"assignerOrgId\": \"2e0a0ee2-d866-482a-9f5e-ac03d156dbaa\", \"datePublished\": \"2023-12-31T09:57:27.448Z\", \"assignerShortName\": \"Moxa\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…