cve-2023-40069
Vulnerability from cvelistv5
Published
2023-08-18 09:44
Modified
2024-10-08 19:14
Severity ?
EPSS score ?
Summary
OS command injection vulnerability in ELECOM wireless LAN routers allows an attacker who can access the product to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-F1167ACF all versions, WRC-1750GHBK all versions, WRC-1167GHBK2 all versions, WRC-1750GHBK2-I all versions, and WRC-1750GHBK-E all versions.
References
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU91630351/ | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.elecom.co.jp/news/security/20230810-01/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU91630351/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.elecom.co.jp/news/security/20230810-01/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | ELECOM CO.,LTD. | WRC-F1167ACF |
Version: all versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T18:24:55.278Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU91630351/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:elecom:wrc-f1167acf_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "wrc-f1167acf_firmware", "vendor": "elecom", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:elecom:wrc-1750ghbk_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "wrc-1750ghbk_firmware", "vendor": "elecom", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:elecom:wrc-1167ghbk2_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "wrc-1167ghbk2_firmware", "vendor": "elecom", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:elecom:wrc-1750ghbk2-i_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "wrc-1750ghbk2-i_firmware", "vendor": "elecom", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:elecom:wrc-1750ghbk-e_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "wrc-1750ghbk-e_firmware", "vendor": "elecom", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-40069", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T18:55:06.435949Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T19:14:06.984Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "WRC-F1167ACF", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1167GHBK2", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK2-I", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "product": "WRC-1750GHBK-E", "vendor": "ELECOM CO.,LTD.", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "OS command injection vulnerability in ELECOM wireless LAN routers allows an attacker who can access the product to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-F1167ACF all versions, WRC-1750GHBK all versions, WRC-1167GHBK2 all versions, WRC-1750GHBK2-I all versions, and WRC-1750GHBK-E all versions." } ], "problemTypes": [ { "descriptions": [ { "description": "OS command injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-18T09:44:43.138Z", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "url": "https://www.elecom.co.jp/news/security/20230810-01/" }, { "url": "https://jvn.jp/en/vu/JVNVU91630351/" } ] } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2023-40069", "datePublished": "2023-08-18T09:44:43.138Z", "dateReserved": "2023-08-09T11:54:57.640Z", "dateUpdated": "2024-10-08T19:14:06.984Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-40069\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-08-18T10:15:12.653\",\"lastModified\":\"2024-11-21T08:18:38.257\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"OS command injection vulnerability in ELECOM wireless LAN routers allows an attacker who can access the product to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-F1167ACF all versions, WRC-1750GHBK all versions, WRC-1167GHBK2 all versions, WRC-1750GHBK2-I all versions, and WRC-1750GHBK-E all versions.\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en los routers LAN inal\u00e1mbricos ELECOM permite a un atacante que pueda acceder al producto ejecutar un comando arbitrario del sistema operativo enviando una solicitud especialmente dise\u00f1ada. Los productos y versiones afectados son los siguientes WRC-F1167ACF todas las versiones, WRC-1750GHBK todas las versiones, WRC-1167GHBK2 todas las versiones, WRC-1750GHBK2-I todas las versiones y WRC-1750GHBK-E todas las versiones.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:elecom:wrc-f1167acf_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0233A6C1-4F74-4347-B204-899F0504E713\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:elecom:wrc-f1167acf:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C244EA13-D45C-4968-A330-3AD80F588537\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:elecom:wrc-1750ghbk_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E00CABDD-B213-4DAA-9FC4-D907AC465134\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:elecom:wrc-1750ghbk:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D1F1675-60C1-4150-8306-1592F88D3DAC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:elecom:wrc-1167ghbk2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07F1B061-C150-4DED-B3DE-B6DDB67AF1C4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:elecom:wrc-1167ghbk2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7DF1D75E-EF09-4BF7-AC5C-F6CDC5B6ED8E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:elecom:wrc-1750ghbk2-i_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"491E938A-060D-4A3E-B466-F2BC12DEF9F1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:elecom:wrc-1750ghbk2-i:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E1EAF366-E7EB-4864-BB1C-16D828141CFD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:elecom:wrc-1750ghbk-e_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"680D6E21-6065-4FCA-A8E6-DF53BD2E4927\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:elecom:wrc-1750ghbk-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDB8292C-ABDA-4F61-8EF1-D498AE3BF66C\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU91630351/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.elecom.co.jp/news/security/20230810-01/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/vu/JVNVU91630351/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.elecom.co.jp/news/security/20230810-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.