cve-2023-31310
Vulnerability from cvelistv5
Published
2024-08-13 16:54
Modified
2024-10-31 14:14
Severity ?
EPSS score ?
Summary
Improper input validation in Power Management Firmware (PMFW) may allow an attacker with privileges to send a malformed input for the "set temperature input selection" command, potentially resulting in a loss of integrity and/or availability.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | AMD | AMD Radeon™ RX 6000 Series Graphics Cards | |||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-31310", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-14T16:05:51.418481Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284 Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-31T14:14:29.589Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "affected", "product": "AMD Radeon\u2122 RX 6000 Series Graphics Cards", "vendor": "AMD", "versions": [ { "status": "unaffected", "version": "AMD Software: Adrenalin Edition 23.12.1 (23.30.13.01)" } ] }, { "defaultStatus": "affected", "product": "AMD Radeon\u2122 PRO W6000 Series Graphics Cards", "vendor": "AMD", "versions": [ { "status": "unaffected", "version": "AMD Software: PRO Edition 23.Q4 (23.30.13.03)" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper input validation in Power Management Firmware (PMFW) may allow an attacker with privileges to send a malformed input for the \"set temperature input selection\" command, potentially resulting in a loss of integrity and/or availability." } ], "value": "Improper input validation in Power Management Firmware (PMFW) may allow an attacker with privileges to send a malformed input for the \"set temperature input selection\" command, potentially resulting in a loss of integrity and/or availability." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T16:54:05.783Z", "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648", "shortName": "AMD" }, "references": [ { "url": "https://www.amd.com/en/resources/product-security/bulletin/amd-sb-6005.html" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648", "assignerShortName": "AMD", "cveId": "CVE-2023-31310", "datePublished": "2024-08-13T16:54:05.783Z", "dateReserved": "2023-04-27T15:25:41.422Z", "dateUpdated": "2024-10-31T14:14:29.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-31310\",\"sourceIdentifier\":\"psirt@amd.com\",\"published\":\"2024-08-13T17:15:20.683\",\"lastModified\":\"2024-10-31T15:35:04.980\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper input validation in Power Management Firmware (PMFW) may allow an attacker with privileges to send a malformed input for the \\\"set temperature input selection\\\" command, potentially resulting in a loss of integrity and/or availability.\"},{\"lang\":\"es\",\"value\":\"Una validaci\u00f3n de entrada incorrecta en el firmware de administraci\u00f3n de energ\u00eda (PMFW) puede permitir que un atacante con privilegios env\u00ede una entrada con formato incorrecto para el comando \\\"establecer selecci\u00f3n de entrada de temperatura\\\", lo que podr\u00eda provocar una p\u00e9rdida de integridad y/o disponibilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.8,\"impactScore\":3.7}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1284\"}]}],\"references\":[{\"url\":\"https://www.amd.com/en/resources/product-security/bulletin/amd-sb-6005.html\",\"source\":\"psirt@amd.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.