cve-2023-1162
Vulnerability from cvelistv5
Published
2023-03-03 06:49
Modified
2024-08-02 05:40
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is an unknown function of the file mainfunction.cgi of the component Web Management Interface. The manipulation of the argument password leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-222258 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md | Exploit | |
cna@vuldb.com | https://vuldb.com/?ctiid.222258 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.222258 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md | Exploit | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.222258 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.222258 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | DrayTek | Vigor 2960 |
Version: 1.5.1.4 Version: 1.5.1.5 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:40:58.063Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.222258" }, { "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.222258" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "modules": [ "Web Management Interface" ], "product": "Vigor 2960", "vendor": "DrayTek", "versions": [ { "status": "affected", "version": "1.5.1.4" }, { "status": "affected", "version": "1.5.1.5" } ] } ], "credits": [ { "lang": "en", "type": "analyst", "value": "Tmotfl (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is an unknown function of the file mainfunction.cgi of the component Web Management Interface. The manipulation of the argument password leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-222258 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in DrayTek Vigor 2960 1.5.1.4/1.5.1.5 gefunden. Sie wurde als kritisch eingestuft. Dabei betrifft es einen unbekannter Codeteil der Datei mainfunction.cgi der Komponente Web Management Interface. Durch die Manipulation des Arguments password mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 8.3, "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-22T20:43:43.932Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.222258" }, { "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.222258" }, { "tags": [ "exploit" ], "url": "https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md" } ], "tags": [ "unsupported-when-assigned" ], "timeline": [ { "lang": "en", "time": "2023-02-25T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2023-02-25T00:00:00.000Z", "value": "Exploit disclosed" }, { "lang": "en", "time": "2023-03-03T00:00:00.000Z", "value": "CVE reserved" }, { "lang": "en", "time": "2023-03-03T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2023-11-22T21:46:54.000Z", "value": "VulDB entry last update" } ], "title": "DrayTek Vigor 2960 Web Management Interface mainfunction.cgi command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2023-1162", "datePublished": "2023-03-03T06:49:57.117Z", "dateReserved": "2023-03-03T06:49:22.252Z", "dateUpdated": "2024-08-02T05:40:58.063Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-1162\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2023-03-03T07:15:09.140\",\"lastModified\":\"2024-11-21T07:38:34.957\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cna@vuldb.com\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is an unknown function of the file mainfunction.cgi of the component Web Management Interface. The manipulation of the argument password leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-222258 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:M/C:C/I:C/A:C\",\"baseScore\":8.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"MULTIPLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":6.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:draytek:vigor_2960_firmware:1.5.1.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C9B7A8F-2F3D-4F78-B8BC-8A796D92AD3A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:draytek:vigor_2960:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57D6E31A-4AE7-481A-B7A4-1C198B01F8FB\"}]}]}],\"references\":[{\"url\":\"https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\"]},{\"url\":\"https://vuldb.com/?ctiid.222258\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.222258\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/xxy1126/Vuln/blob/main/Draytek/2.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\"]},{\"url\":\"https://vuldb.com/?ctiid.222258\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.222258\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.