A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-18 15:14 UTC
CWE
- CWE-664 - Improper Control of a Resource Through its Lifetime
Assigner
References
Impacted products
20 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC622-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC626-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC632-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC636-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC642-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V2.3
(custom)
|
guessed | |
| Siemens | SCALANCE SC646-2C |
Affected:
V2.3 , < V3.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V2.0.0
(custom)
|
guessed | |
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V2.0.0
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.262Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46144",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:14:39.836171Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:58.124Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "V2.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-664",
"description": "CWE-664: Improper Control of a Resource Through its Lifetime",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:12.880Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46144",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-28T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:58.124Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-46144",
"date": "2026-09-13",
"epss": "0.0087",
"percentile": "0.56784"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"B5126C71-4E23-470A-BDD9-E455E5BC645C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"12FE7784-D59A-4E1E-8551-06CCFED772E4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"4C5CB015-BBE7-4D22-A2DD-692D107005AA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"990EB0C2-0B61-4C6D-92FE-BFAC8E6FF7D1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"E967C6E7-943B-4249-86F9-BF17C00161DB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C64B24A5-BC52-4812-80BA-3F183641782F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"BE7993B0-E74F-46FA-83D5-DB29BCA7AD76\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0E5F0040-9B10-4E6B-85AE-E4D04CFC42D0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"7F8CBBC5-960B-4A41-8470-E6E58EFACF0C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"900B67C4-DC4D-47FC-9F5A-E53A23398C95\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"B3CEFD91-BD2A-468E-A5E8-4B1EB30D3A45\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2743D36E-2DEC-4250-B1B2-F1009A47590E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"028A3918-521C-4AF6-AC54-EDBA7805F43B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"12FE7784-D59A-4E1E-8551-06CCFED772E4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"7BE1CF07-0D43-4AC2-9733-1D3C01E0D504\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"990EB0C2-0B61-4C6D-92FE-BFAC8E6FF7D1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"C0BF8D49-DB9D-4313-969E-7227D31D03B2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C64B24A5-BC52-4812-80BA-3F183641782F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"9373F5DA-412B-4801-9CB2-8D49125EA21A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0E5F0040-9B10-4E6B-85AE-E4D04CFC42D0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"D867739D-E78A-4F4B-964F-3D355BC575E5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"900B67C4-DC4D-47FC-9F5A-E53A23398C95\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3\", \"matchCriteriaId\": \"6A5F8C7B-305B-4ADA-B9C1-B38F336927CB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2743D36E-2DEC-4250-B1B2-F1009A47590E\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en: \\nSCALANCE SC622-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC622-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC626-2C (Todas las versiones \u0026lt; V2.3 ), \\nSCALANCE SC626-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC632-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC632-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0 ), \\nSCALANCE SC636-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC636-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC642-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC642 -2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC646-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC646-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0). \\nLos dispositivos afectados no procesan correctamente los comandos de la Interfaz de L\\u00ednea de Comandos (CLI) despu\\u00e9s de que un usuario abandon\\u00f3 por la fuerza la conexi\\u00f3n SSH. Esto podr\\u00eda permitir que un atacante autenticado haga que la Interfaz de L\\u00ednea de Comandos (CLI) a trav\\u00e9s de SSH o la interfaz serie no responda.\"}]",
"id": "CVE-2022-46144",
"lastModified": "2025-01-14T11:15:12.270",
"metrics": "{\"cvssMetricV40\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"HIGH\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}]}",
"published": "2022-12-13T16:15:25.200",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-664\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-46144\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-12-13T16:15:25.200\",\"lastModified\":\"2026-06-17T05:11:17.670\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: \\nSCALANCE SC622-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC622-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC626-2C (Todas las versiones \u0026lt; V2.3 ), \\nSCALANCE SC626-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC632-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC632-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0 ), \\nSCALANCE SC636-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC636-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC642-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC642 -2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0), \\nSCALANCE SC646-2C (Todas las versiones \u0026lt; V2.3), \\nSCALANCE SC646-2C (Todas las versiones \u0026gt;= 2.3 \u0026lt; V3.0). \\nLos dispositivos afectados no procesan correctamente los comandos de la Interfaz de L\u00ednea de Comandos (CLI) despu\u00e9s de que un usuario abandon\u00f3 por la fuerza la conexi\u00f3n SSH. Esto podr\u00eda permitir que un atacante autenticado haga que la Interfaz de L\u00ednea de Comandos (CLI) a trav\u00e9s de SSH o la interfaz serie no responda.\"}],\"affected\":[{\"source\":\"productcert@siemens.com\",\"affectedData\":[{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC622-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC622-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC626-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC626-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC632-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC632-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC636-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC636-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC642-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC642-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC646-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE SC646-2C\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"V2.3\",\"lessThan\":\"V3.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 EEC\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 EEC (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM766-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM766-1 (USA)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V2.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-04-18T15:14:39.836171Z\",\"id\":\"CVE-2022-46144\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-664\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"B5126C71-4E23-470A-BDD9-E455E5BC645C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"12FE7784-D59A-4E1E-8551-06CCFED772E4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"4C5CB015-BBE7-4D22-A2DD-692D107005AA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"990EB0C2-0B61-4C6D-92FE-BFAC8E6FF7D1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"E967C6E7-943B-4249-86F9-BF17C00161DB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C64B24A5-BC52-4812-80BA-3F183641782F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"BE7993B0-E74F-46FA-83D5-DB29BCA7AD76\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E5F0040-9B10-4E6B-85AE-E4D04CFC42D0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"7F8CBBC5-960B-4A41-8470-E6E58EFACF0C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"900B67C4-DC4D-47FC-9F5A-E53A23398C95\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"B3CEFD91-BD2A-468E-A5E8-4B1EB30D3A45\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2743D36E-2DEC-4250-B1B2-F1009A47590E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5622-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"028A3918-521C-4AF6-AC54-EDBA7805F43B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5622-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"12FE7784-D59A-4E1E-8551-06CCFED772E4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5626-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"7BE1CF07-0D43-4AC2-9733-1D3C01E0D504\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5626-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"990EB0C2-0B61-4C6D-92FE-BFAC8E6FF7D1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5632-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"C0BF8D49-DB9D-4313-969E-7227D31D03B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5632-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C64B24A5-BC52-4812-80BA-3F183641782F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5636-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"9373F5DA-412B-4801-9CB2-8D49125EA21A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5636-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E5F0040-9B10-4E6B-85AE-E4D04CFC42D0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5642-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"D867739D-E78A-4F4B-964F-3D355BC575E5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5642-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"900B67C4-DC4D-47FC-9F5A-E53A23398C95\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5646-2gs00-2ac2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3\",\"matchCriteriaId\":\"6A5F8C7B-305B-4ADA-B9C1-B38F336927CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5646-2gs00-2ac2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2743D36E-2DEC-4250-B1B2-F1009A47590E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"redhat_vex": {
"current_release_date": "2025-05-29T01:41:42+00:00",
"cve": "CVE-2022-46144",
"id": "CVE-2022-46144",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-46144",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-46144.json",
"version": "3"
},
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:24:03.262Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-46144\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-18T15:14:39.836171Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-18T15:14:41.888Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC622-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC622-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC626-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC626-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC632-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC632-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC636-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC636-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC642-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC642-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC646-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC646-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.3\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-413565.html\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-664\", \"description\": \"CWE-664: Improper Control of a Resource Through its Lifetime\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-01-14T10:27:12.880Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-46144\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-21T13:42:58.124Z\", \"dateReserved\": \"2022-11-28T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-12-13T00:00:00.000Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…