CVE-2022-45093 (GCVE-0-2022-45093)
Vulnerability from cvelistv5
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:01:31.489Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-45093", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-09T14:02:57.941614Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-09T14:03:09.734Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEC INS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-10T11:39:43.047Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-45093", "datePublished": "2023-01-10T11:39:43.047Z", "dateReserved": "2022-11-09T14:32:46.476Z", "dateUpdated": "2025-04-09T14:03:09.734Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-45093\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-01-10T12:15:23.523\",\"lastModified\":\"2024-11-21T07:28:46.053\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0\",\"matchCriteriaId\":\"C89891C1-DFD7-4E1F-80A9-7485D86A15B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4664B195-AF14-4834-82B3-0B2C98020EB6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"75BC588E-CDF0-404E-AD61-02093A1DF343\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A334F7B4-7283-4453-BAED-D2E01B7F8A6E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:01:31.489Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-45093\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-09T14:02:57.941614Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-09T14:03:03.825Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.5, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SINEC INS\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V1.0 SP2 Update 1\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-22\", \"description\": \"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-01-10T11:39:43.047Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-45093\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-09T14:03:09.734Z\", \"dateReserved\": \"2022-11-09T14:32:46.476Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-01-10T11:39:43.047Z\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
cnvd-2023-02707
Vulnerability from cnvd
目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://cert-portal.siemens.com/productcert/html/ssa-332410.html
Name | Siemens SINEC INS <1.0 SP2 Update 1 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-45093" } }, "description": "SINEC INS\uff08\u57fa\u7840\u8bbe\u65bd\u7f51\u7edc\u670d\u52a1\uff09\u662f\u4e00\u4e2a\u57fa\u4e8eweb\u7684\u5e94\u7528\u7a0b\u5e8f\uff0c\u5c06\u5404\u79cd\u7f51\u7edc\u670d\u52a1\u7ed3\u5408\u5728\u4e00\u4e2a\u5de5\u5177\u4e2d\u3002\u8fd9\u7b80\u5316\u4e86\u4e0e\u5de5\u4e1a\u7f51\u7edc\u76f8\u5173\u7684\u6240\u6709\u7f51\u7edc\u670d\u52a1\u7684\u5b89\u88c5\u548c\u7ba1\u7406\u3002\n\nSiemens SINEC INS\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u89e6\u53d1\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002", "formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-332410.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2023-02707", "openTime": "2023-01-13", "patchDescription": "SINEC INS\uff08\u57fa\u7840\u8bbe\u65bd\u7f51\u7edc\u670d\u52a1\uff09\u662f\u4e00\u4e2a\u57fa\u4e8eweb\u7684\u5e94\u7528\u7a0b\u5e8f\uff0c\u5c06\u5404\u79cd\u7f51\u7edc\u670d\u52a1\u7ed3\u5408\u5728\u4e00\u4e2a\u5de5\u5177\u4e2d\u3002\u8fd9\u7b80\u5316\u4e86\u4e0e\u5de5\u4e1a\u7f51\u7edc\u76f8\u5173\u7684\u6240\u6709\u7f51\u7edc\u670d\u52a1\u7684\u5b89\u88c5\u548c\u7ba1\u7406\u3002\r\n\r\nSiemens SINEC INS\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u89e6\u53d1\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SINEC INS\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff08CNVD-2023-02707\uff09\u7684\u8865\u4e01", "products": { "product": "Siemens SINEC INS \u003c1.0 SP2 Update 1" }, "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-332410.html", "serverity": "\u9ad8", "submitTime": "2023-01-13", "title": "Siemens SINEC INS\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff08CNVD-2023-02707\uff09" }
var-202301-0546
Vulnerability from variot
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component. SINEC INS Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202301-0546", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinec ins", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "sinec ins", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "sinec ins", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "1.0 sp2 update 1" }, { "model": "sinec ins", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "cve": "CVE-2022-45093", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-45093", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2022-45093", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-45093", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-45093", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2022-45093", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-45093", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202301-799", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "CNNVD", "id": "CNNVD-202301-799" }, { "db": "NVD", "id": "CVE-2022-45093" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component. SINEC INS Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45093" }, { "db": "JVNDB", "id": "JVNDB-2023-001807" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45093", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-332410", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-23-017-03", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU90782730", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-001807", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202301-799", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "CNNVD", "id": "CNNVD-202301-799" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "id": "VAR-202301-0546", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.20766129 }, "last_update_date": "2024-08-14T12:22:08.537000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-332410", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" }, { "title": "Siemens SINEC NMS Repair measures for path traversal vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=221681" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "CNNVD", "id": "CNNVD-202301-799" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.0 }, { "problemtype": "Path traversal (CWE-22) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90782730/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45093" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-017-03" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45093/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "CNNVD", "id": "CNNVD-202301-799" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "db": "CNNVD", "id": "CNNVD-202301-799" }, { "db": "NVD", "id": "CVE-2022-45093" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "date": "2023-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-799" }, { "date": "2023-01-10T12:15:23.523000", "db": "NVD", "id": "CVE-2022-45093" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-16T03:25:00", "db": "JVNDB", "id": "JVNDB-2023-001807" }, { "date": "2023-01-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-799" }, { "date": "2023-01-14T00:43:41.810000", "db": "NVD", "id": "CVE-2022-45093" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-799" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SINEC\u00a0INS\u00a0 Past traversal vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-001807" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "path traversal", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-799" } ], "trust": 0.6 } }
ghsa-7qfq-9585-7jw2
Vulnerability from github
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
{ "affected": [], "aliases": [ "CVE-2022-45093" ], "database_specific": { "cwe_ids": [ "CWE-22" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-01-10T12:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "id": "GHSA-7qfq-9585-7jw2", "modified": "2023-01-14T03:30:22Z", "published": "2023-01-10T12:30:23Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-45093" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2022-45093
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-45093", "description": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "id": "GSD-2022-45093" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-45093" ], "details": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "id": "GSD-2022-45093", "modified": "2023-12-13T01:19:24.796251Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-45093", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEC INS", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V1.0 SP2 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component." } ] }, "impact": { "cvss": [ { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-22", "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-45093" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-01-14T00:43Z", "publishedDate": "2023-01-10T12:15Z" } } }
fkie_cve-2022-45093
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*", "matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5", "versionEndExcluding": "1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones " } ], "id": "CVE-2022-45093", "lastModified": "2024-11-21T07:28:46.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-01-10T12:15:23.523", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
ICSA-23-017-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components.\n\nSiemens has released an update for SINEC INS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-332410.json" }, { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-332410.txt" }, { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-23-017-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-017-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-017-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-017-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEC INS", "tracking": { "current_release_date": "2023-01-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-017-03", "initial_release_date": "2023-01-10T00:00:00.000000Z", "revision_history": [ { "date": "2023-01-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.0_SP2_Update_1", "product": { "name": "SINEC INS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEC INS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-2068", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehash script does not properly sanitise shell metacharacters to prevent command injection were found by code review. When the CVE-2022-1292 was fixed it was not discovered that there are other places in the script where the file names of certificates being hashed were possibly passed to a command executed through the shell. This script is distributed by some operating systems in a manner where it is automatically executed. On such operating systems, an attacker could execute arbitrary commands with the privileges of the script. Use of the c_rehash script is considered obsolete and should be replaced by the OpenSSL rehash command line tool.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2068" }, { "cve": "CVE-2022-2097", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn\u0027t written. In the special case of \"in place\" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2097" }, { "cve": "CVE-2022-2274", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The OpenSSL 3.0.4 release introduced a serious bug in the RSA implementation for X86_64 CPUs supporting the AVX512IFMA instructions. This issue makes the RSA implementation with 2048 bit private keys incorrect on such machines and memory corruption will happen during the computation. As a consequence of the memory corruption an attacker may be able to trigger a remote code execution on the machine performing the computation. SSL/TLS servers or other servers using 2048 bit RSA private keys running on machines supporting AVX512IFMA instructions of the X86_64 architecture are affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2274" }, { "cve": "CVE-2022-32212", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A OS Command Injection vulnerability exists in Node.js versions \u003c14.20.0, \u003c16.16.0, \u003c18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32212" }, { "cve": "CVE-2022-32213", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "The llhttp parser \u003cv14.20.1, \u003cv16.17.1 and \u003cv18.9.1 in the http module in Node.js does not correctly parse and validate Transfer-Encoding headers and can lead to HTTP Request Smuggling (HRS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32213" }, { "cve": "CVE-2022-32215", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "The llhttp parser \u003cv14.20.1, \u003cv16.17.1 and \u003cv18.9.1 in the http module in Node.js does not correctly handle multi-line Transfer-Encoding headers. This can lead to HTTP Request Smuggling (HRS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32215" }, { "cve": "CVE-2022-32222", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "A cryptographic vulnerability exists on Node.js on linux in versions of 18.x prior to 18.40.0 which allowed a default path for openssl.cnf that might be accessible under some circumstances to a non-admin user instead of /etc/ssl as was the case in versions prior to the upgrade to OpenSSL 3.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32222" }, { "cve": "CVE-2022-35255", "cwe": { "id": "CWE-330", "name": "Use of Insufficiently Random Values" }, "notes": [ { "category": "summary", "text": "Node.js made calls to EntropySource() in SecretKeyGenTraits::DoKeyGen() in src/crypto/crypto_keygen.cc. However, it does not check the return value, it assumes EntropySource() always succeeds, but it can (and sometimes will) fail.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-35255" }, { "cve": "CVE-2022-35256", "cwe": { "id": "CWE-290", "name": "Authentication Bypass by Spoofing" }, "notes": [ { "category": "summary", "text": "The llhttp parser in the http module in Node.js v18.7.0 does not correctly handle header fields that are not terminated with CLRF. This may result in HTTP Request Smuggling.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-35256" }, { "cve": "CVE-2022-45092", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45092" }, { "cve": "CVE-2022-45093", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2022-45093: Disable the SFTP service of the affected product, if not required", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45093" }, { "cve": "CVE-2022-45094", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2022-45094: Disable the DHCP service of the affected product, if not required", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45094" } ] }
icsa-23-017-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components.\n\nSiemens has released an update for SINEC INS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-332410.json" }, { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-332410.txt" }, { "category": "self", "summary": "SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-23-017-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-017-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-017-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-017-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEC INS", "tracking": { "current_release_date": "2023-01-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-017-03", "initial_release_date": "2023-01-10T00:00:00.000000Z", "revision_history": [ { "date": "2023-01-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.0_SP2_Update_1", "product": { "name": "SINEC INS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEC INS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-2068", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehash script does not properly sanitise shell metacharacters to prevent command injection were found by code review. When the CVE-2022-1292 was fixed it was not discovered that there are other places in the script where the file names of certificates being hashed were possibly passed to a command executed through the shell. This script is distributed by some operating systems in a manner where it is automatically executed. On such operating systems, an attacker could execute arbitrary commands with the privileges of the script. Use of the c_rehash script is considered obsolete and should be replaced by the OpenSSL rehash command line tool.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2068" }, { "cve": "CVE-2022-2097", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn\u0027t written. In the special case of \"in place\" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2097" }, { "cve": "CVE-2022-2274", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The OpenSSL 3.0.4 release introduced a serious bug in the RSA implementation for X86_64 CPUs supporting the AVX512IFMA instructions. This issue makes the RSA implementation with 2048 bit private keys incorrect on such machines and memory corruption will happen during the computation. As a consequence of the memory corruption an attacker may be able to trigger a remote code execution on the machine performing the computation. SSL/TLS servers or other servers using 2048 bit RSA private keys running on machines supporting AVX512IFMA instructions of the X86_64 architecture are affected by this issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-2274" }, { "cve": "CVE-2022-32212", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A OS Command Injection vulnerability exists in Node.js versions \u003c14.20.0, \u003c16.16.0, \u003c18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32212" }, { "cve": "CVE-2022-32213", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "The llhttp parser \u003cv14.20.1, \u003cv16.17.1 and \u003cv18.9.1 in the http module in Node.js does not correctly parse and validate Transfer-Encoding headers and can lead to HTTP Request Smuggling (HRS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32213" }, { "cve": "CVE-2022-32215", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "The llhttp parser \u003cv14.20.1, \u003cv16.17.1 and \u003cv18.9.1 in the http module in Node.js does not correctly handle multi-line Transfer-Encoding headers. This can lead to HTTP Request Smuggling (HRS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32215" }, { "cve": "CVE-2022-32222", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "summary", "text": "A cryptographic vulnerability exists on Node.js on linux in versions of 18.x prior to 18.40.0 which allowed a default path for openssl.cnf that might be accessible under some circumstances to a non-admin user instead of /etc/ssl as was the case in versions prior to the upgrade to OpenSSL 3.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32222" }, { "cve": "CVE-2022-35255", "cwe": { "id": "CWE-330", "name": "Use of Insufficiently Random Values" }, "notes": [ { "category": "summary", "text": "Node.js made calls to EntropySource() in SecretKeyGenTraits::DoKeyGen() in src/crypto/crypto_keygen.cc. However, it does not check the return value, it assumes EntropySource() always succeeds, but it can (and sometimes will) fail.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-35255" }, { "cve": "CVE-2022-35256", "cwe": { "id": "CWE-290", "name": "Authentication Bypass by Spoofing" }, "notes": [ { "category": "summary", "text": "The llhttp parser in the http module in Node.js v18.7.0 does not correctly handle header fields that are not terminated with CLRF. This may result in HTTP Request Smuggling.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-35256" }, { "cve": "CVE-2022-45092", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45092" }, { "cve": "CVE-2022-45093", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device\u0027s file system. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2022-45093: Disable the SFTP service of the affected product, if not required", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45093" }, { "cve": "CVE-2022-45094", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "CVE-2022-45094: Disable the DHCP service of the affected product, if not required", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815432/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-45094" } ] }
CERTFR-2023-AVI-0015
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P versions antérieures à V4.5.0 | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller versions antérieures à V4.1.1 Patch 05 | ||
Siemens | N/A | SINEC INS versions antérieures à V1.0 SP2 Update 1 | ||
Siemens | N/A | SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) versions antérieures à V5.4.2 | ||
Siemens | N/A | Solid Edge versions antérieures à V2023 MP1 | ||
Siemens | N/A | JT Open versions antérieures à V13.1.1.0 | ||
Siemens | N/A | Mendix SAML (Mendix 9 compatible, New Track) versions V3.3.x antérieures à V3.3.9 | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 versions antérieures à V4.5.0 Patch 01 | ||
Siemens | N/A | Mendix SAML (Mendix 9 compatible, Upgrade Track) versions V3.3.x antérieures à V3.3.8 | ||
Siemens | N/A | Automation License Manager V5 | ||
Siemens | N/A | JT Open versions antérieures à V11.1.1.0 | ||
Siemens | N/A | Mendix SAML (Mendix 8 compatible) versions V2.3.x antérieures à V2.3.4 | ||
Siemens | N/A | Automation License Manager versions V6 antérieures à V6 SP9 Upd4 | ||
Siemens | N/A | De nombreux produits SIMATIC, SIMOTION, SINAMICS, SINUMERIK et SIPLUS (Se référer au bulletin de sécurité de l'éditeur pour les versions affectées) |
Title | Publication Time | Tags | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P versions ant\u00e9rieures \u00e0 V4.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller versions ant\u00e9rieures \u00e0 V4.1.1 Patch 05", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC INS versions ant\u00e9rieures \u00e0 V1.0 SP2 Update 1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V5.4.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Solid Edge versions ant\u00e9rieures \u00e0 V2023 MP1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT Open versions ant\u00e9rieures \u00e0 V13.1.1.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix SAML (Mendix 9 compatible, New Track) versions V3.3.x ant\u00e9rieures \u00e0 V3.3.9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 versions ant\u00e9rieures \u00e0 V4.5.0 Patch 01", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix SAML (Mendix 9 compatible, Upgrade Track) versions V3.3.x ant\u00e9rieures \u00e0 V3.3.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Automation License Manager V5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT Open versions ant\u00e9rieures \u00e0 V11.1.1.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix SAML (Mendix 8 compatible) versions V2.3.x ant\u00e9rieures \u00e0 V2.3.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Automation License Manager versions V6 ant\u00e9rieures \u00e0 V6 SP9 Upd4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "De nombreux produits SIMATIC, SIMOTION, SINAMICS, SINUMERIK et SIPLUS (Se r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour les versions affect\u00e9es)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2022-32213", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32213" }, { "name": "CVE-2022-35256", "url": "https://www.cve.org/CVERecord?id=CVE-2022-35256" }, { "name": "CVE-2022-1292", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1292" }, { "name": "CVE-2022-38773", "url": "https://www.cve.org/CVERecord?id=CVE-2022-38773" }, { "name": "CVE-2022-47935", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47935" }, { "name": "CVE-2022-45093", "url": "https://www.cve.org/CVERecord?id=CVE-2022-45093" }, { "name": "CVE-2022-2068", "url": "https://www.cve.org/CVERecord?id=CVE-2022-2068" }, { "name": "CVE-2022-45092", "url": "https://www.cve.org/CVERecord?id=CVE-2022-45092" }, { "name": "CVE-2022-45094", "url": "https://www.cve.org/CVERecord?id=CVE-2022-45094" }, { "name": "CVE-2021-44002", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44002" }, { "name": "CVE-2021-44014", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44014" }, { "name": "CVE-2022-43513", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43513" }, { "name": "CVE-2022-32222", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32222" }, { "name": "CVE-2022-32212", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32212" }, { "name": "CVE-2019-13940", "url": "https://www.cve.org/CVERecord?id=CVE-2019-13940" }, { "name": "CVE-2019-10923", "url": "https://www.cve.org/CVERecord?id=CVE-2019-10923" }, { "name": "CVE-2022-2274", "url": "https://www.cve.org/CVERecord?id=CVE-2022-2274" }, { "name": "CVE-2022-32215", "url": "https://www.cve.org/CVERecord?id=CVE-2022-32215" }, { "name": "CVE-2018-4843", "url": "https://www.cve.org/CVERecord?id=CVE-2018-4843" }, { "name": "CVE-2022-47967", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47967" }, { "name": "CVE-2022-46823", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46823" }, { "name": "CVE-2022-2097", "url": "https://www.cve.org/CVERecord?id=CVE-2022-2097" }, { "name": "CVE-2022-35255", "url": "https://www.cve.org/CVERecord?id=CVE-2022-35255" }, { "name": "CVE-2022-43514", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43514" } ], "initial_release_date": "2023-01-10T00:00:00", "last_revision_date": "2023-01-10T00:00:00", "links": [], "reference": "CERTFR-2023-AVI-0015", "revisions": [ { "description": "Version initiale", "revision_date": "2023-01-10T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-936212 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-936212.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-482757 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-482757.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-332410 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-332410.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-476715 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-431678 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-431678.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-997779 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-997779.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-592007 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-592007.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-349422 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-349422.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-496604 du 10 janvier 2023", "url": "https://cert-portal.siemens.com/productcert/html/ssa-496604.html" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.