cve-2022-38452
Vulnerability from cvelistv5
Published
2023-03-21 17:41
Modified
2025-02-26 16:38
Severity ?
EPSS score ?
Summary
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Netgear | Orbi Router RBR750 |
Version: 4.6.8.5 |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T10:54:03.510Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { url: "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595", }, { name: "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595", tags: [ "x_transferred", ], url: "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595", }, { name: "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186", tags: [ "x_transferred", ], url: "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186", }, ], title: "CVE Program Container", }, { metrics: [ { other: { content: { id: "CVE-2022-38452", options: [ { Exploitation: "poc", }, { Automatable: "no", }, { "Technical Impact": "total", }, ], role: "CISA Coordinator", timestamp: "2025-02-26T16:37:53.257184Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2025-02-26T16:38:11.731Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { product: "Orbi Router RBR750", vendor: "Netgear", versions: [ { status: "affected", version: "4.6.8.5", }, ], }, ], descriptions: [ { lang: "en", value: "A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.", }, ], metrics: [ { cvssV3_1: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 7.2, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "HIGH", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-912", description: "CWE-912: Hidden Functionality", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2023-03-29T10:13:38.314Z", orgId: "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", shortName: "talos", }, references: [ { name: "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595", url: "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595", }, { name: "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186", url: "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186", }, ], }, }, cveMetadata: { assignerOrgId: "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", assignerShortName: "talos", cveId: "CVE-2022-38452", datePublished: "2023-03-21T17:41:26.484Z", dateReserved: "2022-08-19T18:57:28.943Z", dateUpdated: "2025-02-26T16:38:11.731Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2022-38452\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2023-03-21T18:15:12.193\",\"lastModified\":\"2024-11-21T07:16:30.377\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-912\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CE366C8-EEC7-4725-AA02-C4ED5E204E01\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B529194C-C440-4BC3-850F-0613FC548F86\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\",\"source\":\"talos-cna@cisco.com\"},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}", vulnrichment: { containers: "{\"cna\": {\"affected\": [{\"vendor\": \"Netgear\", \"product\": \"Orbi Router RBR750\", \"versions\": [{\"version\": \"4.6.8.5\", \"status\": \"affected\"}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-912: Hidden Functionality\", \"type\": \"CWE\", \"cweId\": \"CWE-912\"}]}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\"}}], \"providerMetadata\": {\"orgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"shortName\": \"talos\", \"dateUpdated\": \"2023-03-29T10:13:38.314Z\"}, \"references\": [{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\", \"name\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\"}, {\"url\": \"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\", \"name\": \"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\"}]}, \"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595\"}, {\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\", \"name\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\", \"name\": \"https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T10:54:03.510Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-38452\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-26T16:37:53.257184Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-26T16:38:04.681Z\"}}]}", cveMetadata: "{\"cveId\": \"CVE-2022-38452\", \"assignerOrgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"talos\", \"dateReserved\": \"2022-08-19T18:57:28.943Z\", \"datePublished\": \"2023-03-21T17:41:26.484Z\", \"dateUpdated\": \"2025-02-26T16:38:11.731Z\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.