cve-2022-33889
Vulnerability from cvelistv5
Published
2022-10-03 14:22
Modified
2024-08-03 08:09
Severity ?
Summary
A maliciously crafted GIF or JPEG files when parsed through Autodesk Design Review 2018, and AutoCAD 2023 and 2022 could be used to write beyond the allocated heap buffer. This vulnerability could lead to arbitrary code execution.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Autodesk\u00ae Design Review, Autodesk\u00ae Advance Steel, Autodesk\u00ae Civil 3D\u00ae",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "2018, 2023, 2022"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A maliciously crafted GIF or JPEG files when parsed through Autodesk Design Review 2018, and AutoCAD 2023 and 2022 could be used to write beyond the allocated heap buffer. This vulnerability could lead to arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Heap based Overflow Buffer",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-03T14:22:14",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@autodesk.com",
          "ID": "CVE-2022-33889",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Autodesk\u00ae Design Review, Autodesk\u00ae Advance Steel, Autodesk\u00ae Civil 3D\u00ae",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2018, 2023, 2022"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A maliciously crafted GIF or JPEG files when parsed through Autodesk Design Review 2018, and AutoCAD 2023 and 2022 could be used to write beyond the allocated heap buffer. This vulnerability could lead to arbitrary code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Heap based Overflow Buffer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021",
              "refsource": "MISC",
              "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2022-33889",
    "datePublished": "2022-10-03T14:22:14",
    "dateReserved": "2022-06-16T00:00:00",
    "dateUpdated": "2024-08-03T08:09:22.694Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-33889\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2022-10-03T15:15:17.633\",\"lastModified\":\"2024-11-21T07:08:32.230\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted GIF or JPEG files when parsed through Autodesk Design Review 2018, and AutoCAD 2023 and 2022 could be used to write beyond the allocated heap buffer. This vulnerability could lead to arbitrary code execution.\"},{\"lang\":\"es\",\"value\":\"Un archivo GIF o JPEG dise\u00f1ado de forma maliciosa cuando es analizado mediante Autodesk Design Review versi\u00f3n 2018 y AutoCAD versiones 2023 y 2022, podr\u00eda usarse para escribir m\u00e1s all\u00e1 del b\u00fafer de la pila asignado. Esta vulnerabilidad podr\u00eda conllevar a una ejecuci\u00f3n de c\u00f3digo arbitrario\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"F867A29B-ABEA-40D8-9252-9129DBC4EEEC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"480910B3-5FD0-47EF-98BA-FDFE22945BB0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"354E7B7A-22BA-4EB2-B136-9622A8032167\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"91A206DF-6922-4CF8-9481-E6A4A2953753\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"B0381CFD-48B1-4BA4-9961-64544267F852\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"729710F9-F4F9-4466-8FA2-22A0C0CF9420\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"3CEE7EBE-109D-43EC-9411-8169E589670A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"F1C62E65-FD27-478A-A472-FBDA4C751BB5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"AF33C631-4C2E-4A18-B5E8-A2037BF29196\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"F1A13743-F25B-47BC-902A-E7ADB9ACA577\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"42E5B8D3-9B23-4DC0-B7CE-BB7EC8D981F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"20E3E3AA-051D-44E2-BD4A-8EBFCFD11C8C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"2ACB4E3C-FE40-4416-8484-A3A3B6883286\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"AA7C36AC-ED97-4669-AD61-75AA00F0385C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"E3107206-44ED-45CB-A218-AC8E12CD4409\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"1F4ADAD1-5627-4BD2-A72B-DEC95415261F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"C3357899-6803-4D09-94F0-7A633DB05E85\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"7FDA3E45-B980-4715-80CC-C29B4A3900C3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"9AC1E832-B725-4F72-812F-000ADE262DEA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2023.0.0\",\"versionEndExcluding\":\"2023.1.1\",\"matchCriteriaId\":\"0A20490C-CDFD-4FCE-B5E3-1F2F78A0C531\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2018\",\"matchCriteriaId\":\"376B6A4F-8AF5-4D6E-B39C-2E99F7A81BCD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"213232B9-A40B-436D-A66A-B65C49D59BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*\",\"matchCriteriaId\":\"84ED1789-A17F-48F7-A152-09D2A5C59254\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*\",\"matchCriteriaId\":\"74819924-EB63-4BBF-9986-FEF6100EEE15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix4:*:*:*:*:*:*\",\"matchCriteriaId\":\"100922EF-C773-4798-B352-B16FCAD48F36\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix5:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C7E8CE3-8A75-4357-8722-17E2CE2378CC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix6:*:*:*:*:*:*\",\"matchCriteriaId\":\"41A96F19-544E-471F-B6BF-9CC8E9403A2A\"}]}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021\",\"source\":\"psirt@autodesk.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0021\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.