CVE-2022-32260 (GCVE-0-2022-32260)
Vulnerability from cvelistv5
- CWE-286 - Incorrect User Management
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SINEMA Remote Connect Server |
Version: 0 < V3.2 SP1 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2022-32260", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T18:05:15.415473Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T18:05:33.739Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T07:39:50.426Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEMA Remote Connect Server", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-286", "description": "CWE-286: Incorrect User Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:18.126Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-32260", "datePublished": "2022-06-14T09:22:14", "dateReserved": "2022-06-02T00:00:00", "dateUpdated": "2024-08-03T07:39:50.426Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-32260\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-06-14T10:15:21.157\",\"lastModified\":\"2024-11-21T07:06:02.750\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.1). La aplicaci\u00f3n afectada crea credenciales de usuario temporales para los usuarios de UMC (User Management Component). Un atacante podr\u00eda usar estas credenciales temporales para omitir la autenticaci\u00f3n en determinados escenarios\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.6,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-286\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1\",\"matchCriteriaId\":\"98CC9C9A-FE14-4D50-A8EC-C309229356C8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-381581.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-381581.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-381581.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T07:39:50.426Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-32260\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-09T18:05:15.415473Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-09T18:05:29.700Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SINEMA Remote Connect Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.2 SP1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-381581.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-286\", \"description\": \"CWE-286: Incorrect User Management\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-07-09T12:04:18.126Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-32260\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-03T07:39:50.426Z\", \"dateReserved\": \"2022-06-02T00:00:00\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-06-14T09:22:14\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
ICSA-24-193-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server before V3.2 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-381581.json" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-381581.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Remote Connect Server", "tracking": { "current_release_date": "2024-07-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-24-193-01", "initial_release_date": "2024-07-09T00:00:00.000000Z", "revision_history": [ { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.2_SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "summary", "text": "The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "summary", "text": "The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "summary", "text": "The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the \u0027Manage firmware updates\u0027 role to escalate their privileges on the underlying OS level.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application allows authenticated, low privilege users with the \u0027Manage own remote connections\u0027 permission to retrieve details about other users and group memberships.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39876" } ] }
ICSA-22-167-17
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server is affected by multiple vulnerabilities, including\n\n- A cross-site scripting vulnerability in an error message pop up window (CVE-2022-29034)\n- Several authentication bypass, privilege escalation and integrity check vulnerabilities (CVE-2022-32251 through -32261)\n- A command injection vulnerability in the file upload service (CVE-2022-32262)\n- A chosen-plaintext attack against HTTP over TLS (\"BREACH\", CVE-2022-27221)\n- Information disclosure vulnerabilities in the curl component (CVE-2021-22924 through -22925)\n- Several vulnerabilities in the libexpat library, that could be exploited when the server is parsing untrusted XML files (CVE-2021-45960, CVE-2021-46143, CVE-2022-22822 through -22827, CVE-2022-23852, CVE-2022-23990, CVE-2022-25235 through -25236, CVE-2022-25313 through -25315.\n\nSiemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version. Note that the update also contains additional fixes for vulnerabilities documented in Siemens Security Advisories SSA-244969, SSA-539476, SSA-685781 and SSA-712929.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-484086 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Critical Manufacturing, Commercial Facilities, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-484086.json" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-484086.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-167-17.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-17" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens OpenSSL Affecting Industrial Products", "tracking": { "current_release_date": "2024-07-09T00:00:00.000000Z", "generator": { "date": "2025-09-11T16:39:57.564734Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-167-17", "initial_release_date": "2022-06-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-06-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Move CVE-2022-32260 to SSA-381581 as only fixed with SINEMA Remote Connect Server V3.2 SP1" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22924", "cwe": { "id": "CWE-706", "name": "Use of Incorrectly-Resolved Name or Reference" }, "notes": [ { "category": "summary", "text": "libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse, if one of them matches the setup. Due to errors in the logic, the config matching function did not take \u0027issuercert\u0027 into account and it compared the involved paths *case insensitively*, which could lead to libcurl reusing wrong connections. File paths are, or can be, case sensitive on many systems but not all, and can even vary depending on used file systems. The comparison also didn\u0027t include the \u0027issuer cert\u0027 which a transfer can set to qualify how to verify the server certificate.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-22924" }, { "cve": "CVE-2021-22925", "cwe": { "id": "CWE-908", "name": "Use of Uninitialized Resource" }, "notes": [ { "category": "summary", "text": "curl supports the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl. This rarely used option is used to send variable=content pairs to TELNET servers. Due to flaw in the option parser for sending `NEW_ENV` variables, libcurl could be made to pass on uninitialized data from a stack based buffer to the server. Therefore potentially revealing sensitive internal information to the server using a clear-text network protocol. This could happen because curl did not call and use sscanf() correctly when parsing the string provided by the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-22925" }, { "cve": "CVE-2021-45960", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.3, a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-45960" }, { "cve": "CVE-2021-46143", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In doProlog in xmlparse.c in Expat (aka libexpat) before 2.4.3, an integer overflow exists for m_groupSize.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-46143" }, { "cve": "CVE-2022-22822", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "addBinding in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22822" }, { "cve": "CVE-2022-22823", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "build_model in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22823" }, { "cve": "CVE-2022-22824", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "defineAttribute in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22824" }, { "cve": "CVE-2022-22825", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "lookup in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22825" }, { "cve": "CVE-2022-22826", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22826" }, { "cve": "CVE-2022-22827", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "storeAtts in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22827" }, { "cve": "CVE-2022-23852", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat (aka libexpat) before 2.4.4 has a signed integer overflow in XML_GetBuffer, for configurations with a nonzero XML_CONTEXT_BYTES.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23852" }, { "cve": "CVE-2022-23990", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat (aka libexpat) before 2.4.4 has an integer overflow in the doProlog function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23990" }, { "cve": "CVE-2022-25235", "cwe": { "id": "CWE-116", "name": "Improper Encoding or Escaping of Output" }, "notes": [ { "category": "summary", "text": "xmltok_impl.c in Expat (aka libexpat) before 2.4.5 lacks certain validation of encoding, such as checks for whether a UTF-8 character is valid in a certain context.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25235" }, { "cve": "CVE-2022-25236", "cwe": { "id": "CWE-668", "name": "Exposure of Resource to Wrong Sphere" }, "notes": [ { "category": "summary", "text": "xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25236" }, { "cve": "CVE-2022-25313", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, an attacker can trigger stack exhaustion in build_model via a large nesting depth in the DTD element.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25313" }, { "cve": "CVE-2022-25314", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, there is an integer overflow in copyString.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25314" }, { "cve": "CVE-2022-25315", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, there is an integer overflow in storeRawNames.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25315" }, { "cve": "CVE-2022-27221", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a \"BREACH\" attack.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-27221" }, { "cve": "CVE-2022-29034", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code.\r\n\r\nThis could allow attackers to perform reflected cross-site scripting (XSS) attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-29034" }, { "cve": "CVE-2022-32251", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32251" }, { "cve": "CVE-2022-32252", "cwe": { "id": "CWE-345", "name": "Insufficient Verification of Data Authenticity" }, "notes": [ { "category": "summary", "text": "The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32252" }, { "cve": "CVE-2022-32253", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Due to improper input validation, the OpenSSL certificate\u0027s password could be printed to a file reachable by an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32253" }, { "cve": "CVE-2022-32254", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "summary", "text": "A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32254" }, { "cve": "CVE-2022-32255", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32255" }, { "cve": "CVE-2022-32256", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32256" }, { "cve": "CVE-2022-32258", "cwe": { "id": "CWE-448", "name": "Obsolete Feature in UI" }, "notes": [ { "category": "summary", "text": "The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32258" }, { "cve": "CVE-2022-32259", "cwe": { "id": "CWE-1244", "name": "Internal Asset Exposed to Unsafe Debug Access Level or State" }, "notes": [ { "category": "summary", "text": "The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32259" }, { "cve": "CVE-2022-32261", "cwe": { "id": "CWE-233", "name": "Improper Handling of Parameters" }, "notes": [ { "category": "summary", "text": "The affected application contains a misconfiguration in the APT update. This could allow an attacker to add insecure packages to the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32261" }, { "cve": "CVE-2022-32262", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32262" } ] }
icsa-24-193-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server before V3.2 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-381581.json" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-381581.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Remote Connect Server", "tracking": { "current_release_date": "2024-07-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-24-193-01", "initial_release_date": "2024-07-09T00:00:00.000000Z", "revision_history": [ { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.2_SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "summary", "text": "The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "summary", "text": "The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "summary", "text": "The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the \u0027Manage firmware updates\u0027 role to escalate their privileges on the underlying OS level.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application allows authenticated, low privilege users with the \u0027Manage own remote connections\u0027 permission to retrieve details about other users and group memberships.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-39876" } ] }
icsa-22-167-17
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server is affected by multiple vulnerabilities, including\n\n- A cross-site scripting vulnerability in an error message pop up window (CVE-2022-29034)\n- Several authentication bypass, privilege escalation and integrity check vulnerabilities (CVE-2022-32251 through -32261)\n- A command injection vulnerability in the file upload service (CVE-2022-32262)\n- A chosen-plaintext attack against HTTP over TLS (\"BREACH\", CVE-2022-27221)\n- Information disclosure vulnerabilities in the curl component (CVE-2021-22924 through -22925)\n- Several vulnerabilities in the libexpat library, that could be exploited when the server is parsing untrusted XML files (CVE-2021-45960, CVE-2021-46143, CVE-2022-22822 through -22827, CVE-2022-23852, CVE-2022-23990, CVE-2022-25235 through -25236, CVE-2022-25313 through -25315.\n\nSiemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version. Note that the update also contains additional fixes for vulnerabilities documented in Siemens Security Advisories SSA-244969, SSA-539476, SSA-685781 and SSA-712929.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-484086 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Critical Manufacturing, Commercial Facilities, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-484086.json" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "category": "self", "summary": "SSA-484086: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-484086.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-167-17.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-167-17 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-17" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens OpenSSL Affecting Industrial Products", "tracking": { "current_release_date": "2024-07-09T00:00:00.000000Z", "generator": { "date": "2025-09-11T16:39:57.564734Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-167-17", "initial_release_date": "2022-06-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-06-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Move CVE-2022-32260 to SSA-381581 as only fixed with SINEMA Remote Connect Server V3.2 SP1" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22924", "cwe": { "id": "CWE-706", "name": "Use of Incorrectly-Resolved Name or Reference" }, "notes": [ { "category": "summary", "text": "libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse, if one of them matches the setup. Due to errors in the logic, the config matching function did not take \u0027issuercert\u0027 into account and it compared the involved paths *case insensitively*, which could lead to libcurl reusing wrong connections. File paths are, or can be, case sensitive on many systems but not all, and can even vary depending on used file systems. The comparison also didn\u0027t include the \u0027issuer cert\u0027 which a transfer can set to qualify how to verify the server certificate.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-22924" }, { "cve": "CVE-2021-22925", "cwe": { "id": "CWE-908", "name": "Use of Uninitialized Resource" }, "notes": [ { "category": "summary", "text": "curl supports the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl. This rarely used option is used to send variable=content pairs to TELNET servers. Due to flaw in the option parser for sending `NEW_ENV` variables, libcurl could be made to pass on uninitialized data from a stack based buffer to the server. Therefore potentially revealing sensitive internal information to the server using a clear-text network protocol. This could happen because curl did not call and use sscanf() correctly when parsing the string provided by the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-22925" }, { "cve": "CVE-2021-45960", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.3, a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-45960" }, { "cve": "CVE-2021-46143", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In doProlog in xmlparse.c in Expat (aka libexpat) before 2.4.3, an integer overflow exists for m_groupSize.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-46143" }, { "cve": "CVE-2022-22822", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "addBinding in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22822" }, { "cve": "CVE-2022-22823", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "build_model in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22823" }, { "cve": "CVE-2022-22824", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "defineAttribute in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22824" }, { "cve": "CVE-2022-22825", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "lookup in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22825" }, { "cve": "CVE-2022-22826", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22826" }, { "cve": "CVE-2022-22827", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "storeAtts in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-22827" }, { "cve": "CVE-2022-23852", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat (aka libexpat) before 2.4.4 has a signed integer overflow in XML_GetBuffer, for configurations with a nonzero XML_CONTEXT_BYTES.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23852" }, { "cve": "CVE-2022-23990", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Expat (aka libexpat) before 2.4.4 has an integer overflow in the doProlog function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-23990" }, { "cve": "CVE-2022-25235", "cwe": { "id": "CWE-116", "name": "Improper Encoding or Escaping of Output" }, "notes": [ { "category": "summary", "text": "xmltok_impl.c in Expat (aka libexpat) before 2.4.5 lacks certain validation of encoding, such as checks for whether a UTF-8 character is valid in a certain context.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25235" }, { "cve": "CVE-2022-25236", "cwe": { "id": "CWE-668", "name": "Exposure of Resource to Wrong Sphere" }, "notes": [ { "category": "summary", "text": "xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25236" }, { "cve": "CVE-2022-25313", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, an attacker can trigger stack exhaustion in build_model via a large nesting depth in the DTD element.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25313" }, { "cve": "CVE-2022-25314", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, there is an integer overflow in copyString.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25314" }, { "cve": "CVE-2022-25315", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In Expat (aka libexpat) before 2.4.5, there is an integer overflow in storeRawNames.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-25315" }, { "cve": "CVE-2022-27221", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a \"BREACH\" attack.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-27221" }, { "cve": "CVE-2022-29034", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code.\r\n\r\nThis could allow attackers to perform reflected cross-site scripting (XSS) attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-29034" }, { "cve": "CVE-2022-32251", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32251" }, { "cve": "CVE-2022-32252", "cwe": { "id": "CWE-345", "name": "Insufficient Verification of Data Authenticity" }, "notes": [ { "category": "summary", "text": "The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32252" }, { "cve": "CVE-2022-32253", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Due to improper input validation, the OpenSSL certificate\u0027s password could be printed to a file reachable by an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32253" }, { "cve": "CVE-2022-32254", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "summary", "text": "A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32254" }, { "cve": "CVE-2022-32255", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32255" }, { "cve": "CVE-2022-32256", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32256" }, { "cve": "CVE-2022-32258", "cwe": { "id": "CWE-448", "name": "Obsolete Feature in UI" }, "notes": [ { "category": "summary", "text": "The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32258" }, { "cve": "CVE-2022-32259", "cwe": { "id": "CWE-1244", "name": "Internal Asset Exposed to Unsafe Debug Access Level or State" }, "notes": [ { "category": "summary", "text": "The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32259" }, { "cve": "CVE-2022-32261", "cwe": { "id": "CWE-233", "name": "Improper Handling of Parameters" }, "notes": [ { "category": "summary", "text": "The affected application contains a misconfiguration in the APT update. This could allow an attacker to add insecure packages to the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32261" }, { "cve": "CVE-2022-32262", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109811169/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-32262" } ] }
ssa-381581
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server before V3.2 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-381581.json" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-381581.txt" } ], "title": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1", "tracking": { "current_release_date": "2024-07-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-381581", "initial_release_date": "2024-07-09T00:00:00Z", "revision_history": [ { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.2 SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "1" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "summary", "text": "The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "summary", "text": "The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "summary", "text": "The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the \u0027Manage firmware updates\u0027 role to escalate their privileges on the underlying OS level.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application allows authenticated, low privilege users with the \u0027Manage own remote connections\u0027 permission to retrieve details about other users and group memberships.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39876" } ] }
SSA-381581
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server before V3.2 SP1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-381581.json" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "self", "summary": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-381581.txt" } ], "title": "SSA-381581: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2 SP1", "tracking": { "current_release_date": "2024-07-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-381581", "initial_release_date": "2024-07-09T00:00:00Z", "revision_history": [ { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.2 SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "1" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "summary", "text": "The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker with access to the backup encryption key to upload malicious files, that could potentially lead to remote code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "summary", "text": "The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "summary", "text": "The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "summary", "text": "The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the \u0027Manage firmware updates\u0027 role to escalate their privileges on the underlying OS level.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "summary", "text": "The affected application allows authenticated, low privilege users with the \u0027Manage own remote connections\u0027 permission to retrieve details about other users and group memberships.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 SP1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972765/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39876" } ] }
var-202206-0847
Vulnerability from variot
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios. SINEMA Remote Connect is a remote network management platform for easy management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202206-0847", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinema remote connect server", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1" } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32260" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens notified CISA of these vulnerabilities.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1241" } ], "trust": 0.6 }, "cve": "CVE-2022-32260", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2022-32260", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-424199", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-32260", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.6, "id": "CVE-2022-32260", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-32260", "trust": 1.0, "value": "CRITICAL" }, { "author": "productcert@siemens.com", "id": "CVE-2022-32260", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202206-1241", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-424199", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-424199" }, { "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "db": "NVD", "id": "CVE-2022-32260" }, { "db": "NVD", "id": "CVE-2022-32260" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios. SINEMA Remote Connect is a remote network management platform for easy management of tunnel connections (VPN) between headquarters, service technicians and installed machines or plants", "sources": [ { "db": "NVD", "id": "CVE-2022-32260" }, { "db": "VULHUB", "id": "VHN-424199" }, { "db": "VULMON", "id": "CVE-2022-32260" } ], "trust": 1.08 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-484086", "trust": 1.8 }, { "db": "NVD", "id": "CVE-2022-32260", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-381581", "trust": 1.0 }, { "db": "ICS CERT", "id": "ICSA-22-167-17", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202206-1241", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2022-45221", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-424199", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2022-32260", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-424199" }, { "db": "VULMON", "id": "CVE-2022-32260" }, { "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "db": "NVD", "id": "CVE-2022-32260" } ] }, "id": "VAR-202206-0847", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-424199" } ], "trust": 0.7003805 }, "last_update_date": "2024-11-23T19:38:36.870000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens SINEMA Remote Connect Server Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=197239" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1241" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-286", "trust": 1.0 }, { "problemtype": "NVD-CWE-Other", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-32260" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-167-17" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-32260/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-17" } ], "sources": [ { "db": "VULHUB", "id": "VHN-424199" }, { "db": "VULMON", "id": "CVE-2022-32260" }, { "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "db": "NVD", "id": "CVE-2022-32260" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-424199" }, { "db": "VULMON", "id": "CVE-2022-32260" }, { "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "db": "NVD", "id": "CVE-2022-32260" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-14T00:00:00", "db": "VULHUB", "id": "VHN-424199" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2022-32260" }, { "date": "2022-06-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "date": "2022-06-14T10:15:21.157000", "db": "NVD", "id": "CVE-2022-32260" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-23T00:00:00", "db": "VULHUB", "id": "VHN-424199" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2022-32260" }, { "date": "2022-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1241" }, { "date": "2024-11-21T07:06:02.750000", "db": "NVD", "id": "CVE-2022-32260" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1241" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SINEMA Remote Connect Server Security hole", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1241" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1241" } ], "trust": 0.6 } }
fkie_cve-2022-32260
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
siemens | sinema_remote_connect_server | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "98CC9C9A-FE14-4D50-A8EC-C309229356C8", "versionEndExcluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.1). La aplicaci\u00f3n afectada crea credenciales de usuario temporales para los usuarios de UMC (User Management Component). Un atacante podr\u00eda usar estas credenciales temporales para omitir la autenticaci\u00f3n en determinados escenarios" } ], "id": "CVE-2022-32260", "lastModified": "2024-11-21T07:06:02.750", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.6, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-06-14T10:15:21.157", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-286" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-wvgf-xgq8-6r6j
Vulnerability from github
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.
{ "affected": [], "aliases": [ "CVE-2022-32260" ], "database_specific": { "cwe_ids": [ "CWE-286" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-06-14T10:15:00Z", "severity": "CRITICAL" }, "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "id": "GHSA-wvgf-xgq8-6r6j", "modified": "2024-07-09T12:30:55Z", "published": "2022-06-15T00:00:29Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-32260" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-381581.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
ncsc-2024-0282
Vulnerability from csaf_ncscnl
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.", "title": "Feiten" }, { "category": "description", "text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n- Toegang tot gevoelige gegevens\n- Verhoogde gebruikersrechten\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" }, { "category": "general", "text": "Stack-based Buffer Overflow", "title": "CWE-121" }, { "category": "general", "text": "Out-of-bounds Read", "title": "CWE-125" }, { "category": "general", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" }, { "category": "general", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" }, { "category": "general", "text": "Truncation of Security-relevant Information", "title": "CWE-222" }, { "category": "general", "text": "Incorrect Privilege Assignment", "title": "CWE-266" }, { "category": "general", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" }, { "category": "general", "text": "Incorrect User Management", "title": "CWE-286" }, { "category": "general", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" }, { "category": "general", "text": "Inadequate Encryption Strength", "title": "CWE-326" }, { "category": "general", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" }, { "category": "general", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" }, { "category": "general", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "general", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" }, { "category": "general", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" }, { "category": "general", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "general", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" }, { "category": "general", "text": "Deserialization of Untrusted Data", "title": "CWE-502" }, { "category": "general", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" }, { "category": "general", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" }, { "category": "general", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" }, { "category": "general", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" }, { "category": "general", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" }, { "category": "general", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" }, { "category": "general", "text": "Out-of-bounds Write", "title": "CWE-787" }, { "category": "general", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" }, { "category": "general", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" }, { "category": "general", "text": "Incorrect Authorization", "title": "CWE-863" }, { "category": "general", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" }, { "category": "general", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-064222.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-088132.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170375.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313039.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364175.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-698820.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-722010.pdf" }, { "category": "external", "summary": "Reference - siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723487.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750499.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779936.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-824889.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-868282.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-883918.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-928781.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-998949.pdf" } ], "title": "Kwetsbaarheden verholpen in Siemens Producten", "tracking": { "current_release_date": "2024-07-09T18:40:57.534939Z", "id": "NCSC-2024-0282", "initial_release_date": "2024-07-09T18:40:57.534939Z", "revision_history": [ { "date": "2024-07-09T18:40:57.534939Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "jt_open", "product": { "name": "jt_open", "product_id": "CSAFPID-1497083", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:jt_open:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "mendix_encryption", "product": { "name": "mendix_encryption", "product_id": "CSAFPID-1497113", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:mendix_encryption:v10.0.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "plm_xml_sdk", "product": { "name": "plm_xml_sdk", "product_id": "CSAFPID-1497084", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:plm_xml_sdk:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ps_iges_parasolid_translator_component", "product": { "name": "ps_iges_parasolid_translator_component", "product_id": "CSAFPID-1464909", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1496944", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497438", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497459", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497481", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497482", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497428", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.5:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497379", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.6:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497388", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.7:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1498045", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.8:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497498", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.9:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1496945", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1497536", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498050", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497507", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498073", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497596", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497876", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497817", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.5:*:*:*:*:*:*:*" } } } ], "category": "vendor", "name": "siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "other", "text": "Incorrect User Management", "title": "CWE-286" } ], "references": [ { "category": "self", "summary": "CVE-2022-32260", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2022/CVE-2022-32260.json" } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2023-7066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-7066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-7066.json" } ], "title": "CVE-2023-7066" }, { "cve": "CVE-2023-27321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-27321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-27321.json" } ], "title": "CVE-2023-27321" }, { "cve": "CVE-2023-32735", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32735", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32735.json" } ], "title": "CVE-2023-32735" }, { "cve": "CVE-2023-32737", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32737", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32737.json" } ], "title": "CVE-2023-32737" }, { "cve": "CVE-2023-46720", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2023-46720", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46720.json" } ], "title": "CVE-2023-46720" }, { "cve": "CVE-2023-48795", "cwe": { "id": "CWE-222", "name": "Truncation of Security-relevant Information" }, "notes": [ { "category": "other", "text": "Truncation of Security-relevant Information", "title": "CWE-222" } ], "references": [ { "category": "self", "summary": "CVE-2023-48795", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-48795.json" } ], "title": "CVE-2023-48795" }, { "cve": "CVE-2023-52237", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "product_status": { "known_affected": [ "CSAFPID-1496944", "CSAFPID-1496945" ] }, "references": [ { "category": "self", "summary": "CVE-2023-52237", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52237.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-1496944", "CSAFPID-1496945" ] } ], "title": "CVE-2023-52237" }, { "cve": "CVE-2023-52238", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "references": [ { "category": "self", "summary": "CVE-2023-52238", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52238.json" } ], "title": "CVE-2023-52238" }, { "cve": "CVE-2023-52891", "cwe": { "id": "CWE-1325", "name": "Improperly Controlled Sequential Memory Allocation" }, "notes": [ { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-52891", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52891.json" } ], "title": "CVE-2023-52891" }, { "cve": "CVE-2024-21754", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "other", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" } ], "references": [ { "category": "self", "summary": "CVE-2024-21754", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-21754.json" } ], "title": "CVE-2024-21754" }, { "cve": "CVE-2024-23111", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" } ], "references": [ { "category": "self", "summary": "CVE-2024-23111", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-23111.json" } ], "title": "CVE-2024-23111" }, { "cve": "CVE-2024-26010", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-26010", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-26010.json" } ], "title": "CVE-2024-26010" }, { "cve": "CVE-2024-30321", "cwe": { "id": "CWE-359", "name": "Exposure of Private Personal Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" } ], "references": [ { "category": "self", "summary": "CVE-2024-30321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-30321.json" } ], "title": "CVE-2024-30321" }, { "cve": "CVE-2024-32055", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32055", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32055.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32055" }, { "cve": "CVE-2024-32056", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "other", "text": "Out-of-bounds Write", "title": "CWE-787" } ], "references": [ { "category": "self", "summary": "CVE-2024-32056", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32056.json" } ], "title": "CVE-2024-32056" }, { "cve": "CVE-2024-32057", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32057", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32057.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32057" }, { "cve": "CVE-2024-32058", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32058", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32058.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32058" }, { "cve": "CVE-2024-32059", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32059", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32059.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32059" }, { "cve": "CVE-2024-32060", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32060", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32060.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32060" }, { "cve": "CVE-2024-32061", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32061", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32061.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32061" }, { "cve": "CVE-2024-32062", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32062", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32062.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32062" }, { "cve": "CVE-2024-32063", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32063", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32063.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32063" }, { "cve": "CVE-2024-32064", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32064", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32064.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32064" }, { "cve": "CVE-2024-32065", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32065", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32065.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32065" }, { "cve": "CVE-2024-32066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32066.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32066" }, { "cve": "CVE-2024-33577", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-33577", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33577.json" } ], "title": "CVE-2024-33577" }, { "cve": "CVE-2024-33653", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33653", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33653.json" } ], "title": "CVE-2024-33653" }, { "cve": "CVE-2024-33654", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33654", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33654.json" } ], "title": "CVE-2024-33654" }, { "cve": "CVE-2024-37996", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37996", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37996.json" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37996" }, { "cve": "CVE-2024-37997", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37997", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37997.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37997" }, { "cve": "CVE-2024-38278", "cwe": { "id": "CWE-266", "name": "Incorrect Privilege Assignment" }, "notes": [ { "category": "other", "text": "Incorrect Privilege Assignment", "title": "CWE-266" } ], "references": [ { "category": "self", "summary": "CVE-2024-38278", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38278.json" } ], "title": "CVE-2024-38278" }, { "cve": "CVE-2024-38867", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "other", "text": "Inadequate Encryption Strength", "title": "CWE-326" } ], "references": [ { "category": "self", "summary": "CVE-2024-38867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38867.json" } ], "title": "CVE-2024-38867" }, { "cve": "CVE-2024-39567", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39567", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39567.json" } ], "title": "CVE-2024-39567" }, { "cve": "CVE-2024-39568", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39568", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39568.json" } ], "title": "CVE-2024-39568" }, { "cve": "CVE-2024-39569", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39569", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39569.json" } ], "title": "CVE-2024-39569" }, { "cve": "CVE-2024-39570", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39570", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39570.json" } ], "title": "CVE-2024-39570" }, { "cve": "CVE-2024-39571", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39571", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39571.json" } ], "title": "CVE-2024-39571" }, { "cve": "CVE-2024-39675", "cwe": { "id": "CWE-497", "name": "Exposure of Sensitive System Information to an Unauthorized Control Sphere" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" } ], "references": [ { "category": "self", "summary": "CVE-2024-39675", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39675.json" } ], "title": "CVE-2024-39675" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "other", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" } ], "references": [ { "category": "self", "summary": "CVE-2024-39865", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39865.json" } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "other", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" } ], "references": [ { "category": "self", "summary": "CVE-2024-39866", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39866.json" } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39867.json" } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39868", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39868.json" } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "other", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" } ], "references": [ { "category": "self", "summary": "CVE-2024-39869", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39869.json" } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "other", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" } ], "references": [ { "category": "self", "summary": "CVE-2024-39870", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39870.json" } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-39871", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39871.json" } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "other", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" } ], "references": [ { "category": "self", "summary": "CVE-2024-39872", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39872.json" } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39873", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39873.json" } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39874", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39874.json" } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "other", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" } ], "references": [ { "category": "self", "summary": "CVE-2024-39875", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39875.json" } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "other", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" } ], "references": [ { "category": "self", "summary": "CVE-2024-39876", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39876.json" } ], "title": "CVE-2024-39876" }, { "cve": "CVE-2024-39888", "cwe": { "id": "CWE-547", "name": "Use of Hard-coded, Security-relevant Constants" }, "notes": [ { "category": "other", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" } ], "product_status": { "known_affected": [ "CSAFPID-1497113" ] }, "references": [ { "category": "self", "summary": "CVE-2024-39888", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39888.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "CSAFPID-1497113" ] } ], "title": "CVE-2024-39888" }, { "cve": "CVE-2024-3596", "cwe": { "id": "CWE-924", "name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel" }, "notes": [ { "category": "other", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" }, { "category": "other", "text": "Use of Weak Hash", "title": "CWE-328" } ], "references": [ { "category": "self", "summary": "CVE-2024-3596", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-3596.json" } ], "title": "CVE-2024-3596" } ] }
NCSC-2024-0282
Vulnerability from csaf_ncscnl
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.", "title": "Feiten" }, { "category": "description", "text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n- Toegang tot gevoelige gegevens\n- Verhoogde gebruikersrechten\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" }, { "category": "general", "text": "Stack-based Buffer Overflow", "title": "CWE-121" }, { "category": "general", "text": "Out-of-bounds Read", "title": "CWE-125" }, { "category": "general", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" }, { "category": "general", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" }, { "category": "general", "text": "Truncation of Security-relevant Information", "title": "CWE-222" }, { "category": "general", "text": "Incorrect Privilege Assignment", "title": "CWE-266" }, { "category": "general", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" }, { "category": "general", "text": "Incorrect User Management", "title": "CWE-286" }, { "category": "general", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" }, { "category": "general", "text": "Inadequate Encryption Strength", "title": "CWE-326" }, { "category": "general", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" }, { "category": "general", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" }, { "category": "general", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "general", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" }, { "category": "general", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" }, { "category": "general", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "general", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" }, { "category": "general", "text": "Deserialization of Untrusted Data", "title": "CWE-502" }, { "category": "general", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" }, { "category": "general", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" }, { "category": "general", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" }, { "category": "general", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" }, { "category": "general", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" }, { "category": "general", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" }, { "category": "general", "text": "Out-of-bounds Write", "title": "CWE-787" }, { "category": "general", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" }, { "category": "general", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" }, { "category": "general", "text": "Incorrect Authorization", "title": "CWE-863" }, { "category": "general", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" }, { "category": "general", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-064222.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-088132.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170375.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313039.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364175.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-698820.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-722010.pdf" }, { "category": "external", "summary": "Reference - siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723487.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750499.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779936.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-824889.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-868282.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-883918.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-928781.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-998949.pdf" } ], "title": "Kwetsbaarheden verholpen in Siemens Producten", "tracking": { "current_release_date": "2024-07-09T18:40:57.534939Z", "id": "NCSC-2024-0282", "initial_release_date": "2024-07-09T18:40:57.534939Z", "revision_history": [ { "date": "2024-07-09T18:40:57.534939Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "jt_open", "product": { "name": "jt_open", "product_id": "CSAFPID-1497083", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:jt_open:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "mendix_encryption", "product": { "name": "mendix_encryption", "product_id": "CSAFPID-1497113", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:mendix_encryption:v10.0.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "plm_xml_sdk", "product": { "name": "plm_xml_sdk", "product_id": "CSAFPID-1497084", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:plm_xml_sdk:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ps_iges_parasolid_translator_component", "product": { "name": "ps_iges_parasolid_translator_component", "product_id": "CSAFPID-1464909", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1496944", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497438", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497459", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497481", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497482", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497428", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.5:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497379", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.6:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497388", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.7:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1498045", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.8:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497498", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.9:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1496945", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1497536", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498050", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497507", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498073", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497596", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497876", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497817", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.5:*:*:*:*:*:*:*" } } } ], "category": "vendor", "name": "siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "other", "text": "Incorrect User Management", "title": "CWE-286" } ], "references": [ { "category": "self", "summary": "CVE-2022-32260", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2022/CVE-2022-32260.json" } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2023-7066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-7066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-7066.json" } ], "title": "CVE-2023-7066" }, { "cve": "CVE-2023-27321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-27321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-27321.json" } ], "title": "CVE-2023-27321" }, { "cve": "CVE-2023-32735", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32735", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32735.json" } ], "title": "CVE-2023-32735" }, { "cve": "CVE-2023-32737", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32737", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32737.json" } ], "title": "CVE-2023-32737" }, { "cve": "CVE-2023-46720", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2023-46720", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46720.json" } ], "title": "CVE-2023-46720" }, { "cve": "CVE-2023-48795", "cwe": { "id": "CWE-222", "name": "Truncation of Security-relevant Information" }, "notes": [ { "category": "other", "text": "Truncation of Security-relevant Information", "title": "CWE-222" } ], "references": [ { "category": "self", "summary": "CVE-2023-48795", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-48795.json" } ], "title": "CVE-2023-48795" }, { "cve": "CVE-2023-52237", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "product_status": { "known_affected": [ "CSAFPID-1496944", "CSAFPID-1496945" ] }, "references": [ { "category": "self", "summary": "CVE-2023-52237", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52237.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-1496944", "CSAFPID-1496945" ] } ], "title": "CVE-2023-52237" }, { "cve": "CVE-2023-52238", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "references": [ { "category": "self", "summary": "CVE-2023-52238", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52238.json" } ], "title": "CVE-2023-52238" }, { "cve": "CVE-2023-52891", "cwe": { "id": "CWE-1325", "name": "Improperly Controlled Sequential Memory Allocation" }, "notes": [ { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-52891", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52891.json" } ], "title": "CVE-2023-52891" }, { "cve": "CVE-2024-21754", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "other", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" } ], "references": [ { "category": "self", "summary": "CVE-2024-21754", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-21754.json" } ], "title": "CVE-2024-21754" }, { "cve": "CVE-2024-23111", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" } ], "references": [ { "category": "self", "summary": "CVE-2024-23111", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-23111.json" } ], "title": "CVE-2024-23111" }, { "cve": "CVE-2024-26010", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-26010", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-26010.json" } ], "title": "CVE-2024-26010" }, { "cve": "CVE-2024-30321", "cwe": { "id": "CWE-359", "name": "Exposure of Private Personal Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" } ], "references": [ { "category": "self", "summary": "CVE-2024-30321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-30321.json" } ], "title": "CVE-2024-30321" }, { "cve": "CVE-2024-32055", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32055", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32055.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32055" }, { "cve": "CVE-2024-32056", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "other", "text": "Out-of-bounds Write", "title": "CWE-787" } ], "references": [ { "category": "self", "summary": "CVE-2024-32056", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32056.json" } ], "title": "CVE-2024-32056" }, { "cve": "CVE-2024-32057", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32057", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32057.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32057" }, { "cve": "CVE-2024-32058", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32058", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32058.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32058" }, { "cve": "CVE-2024-32059", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32059", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32059.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32059" }, { "cve": "CVE-2024-32060", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32060", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32060.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32060" }, { "cve": "CVE-2024-32061", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32061", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32061.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32061" }, { "cve": "CVE-2024-32062", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32062", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32062.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32062" }, { "cve": "CVE-2024-32063", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32063", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32063.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32063" }, { "cve": "CVE-2024-32064", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32064", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32064.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32064" }, { "cve": "CVE-2024-32065", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32065", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32065.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32065" }, { "cve": "CVE-2024-32066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32066.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32066" }, { "cve": "CVE-2024-33577", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-33577", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33577.json" } ], "title": "CVE-2024-33577" }, { "cve": "CVE-2024-33653", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33653", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33653.json" } ], "title": "CVE-2024-33653" }, { "cve": "CVE-2024-33654", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33654", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33654.json" } ], "title": "CVE-2024-33654" }, { "cve": "CVE-2024-37996", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37996", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37996.json" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37996" }, { "cve": "CVE-2024-37997", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37997", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37997.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37997" }, { "cve": "CVE-2024-38278", "cwe": { "id": "CWE-266", "name": "Incorrect Privilege Assignment" }, "notes": [ { "category": "other", "text": "Incorrect Privilege Assignment", "title": "CWE-266" } ], "references": [ { "category": "self", "summary": "CVE-2024-38278", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38278.json" } ], "title": "CVE-2024-38278" }, { "cve": "CVE-2024-38867", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "other", "text": "Inadequate Encryption Strength", "title": "CWE-326" } ], "references": [ { "category": "self", "summary": "CVE-2024-38867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38867.json" } ], "title": "CVE-2024-38867" }, { "cve": "CVE-2024-39567", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39567", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39567.json" } ], "title": "CVE-2024-39567" }, { "cve": "CVE-2024-39568", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39568", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39568.json" } ], "title": "CVE-2024-39568" }, { "cve": "CVE-2024-39569", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39569", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39569.json" } ], "title": "CVE-2024-39569" }, { "cve": "CVE-2024-39570", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39570", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39570.json" } ], "title": "CVE-2024-39570" }, { "cve": "CVE-2024-39571", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39571", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39571.json" } ], "title": "CVE-2024-39571" }, { "cve": "CVE-2024-39675", "cwe": { "id": "CWE-497", "name": "Exposure of Sensitive System Information to an Unauthorized Control Sphere" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" } ], "references": [ { "category": "self", "summary": "CVE-2024-39675", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39675.json" } ], "title": "CVE-2024-39675" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "other", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" } ], "references": [ { "category": "self", "summary": "CVE-2024-39865", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39865.json" } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "other", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" } ], "references": [ { "category": "self", "summary": "CVE-2024-39866", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39866.json" } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39867.json" } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39868", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39868.json" } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "other", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" } ], "references": [ { "category": "self", "summary": "CVE-2024-39869", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39869.json" } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "other", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" } ], "references": [ { "category": "self", "summary": "CVE-2024-39870", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39870.json" } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-39871", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39871.json" } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "other", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" } ], "references": [ { "category": "self", "summary": "CVE-2024-39872", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39872.json" } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39873", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39873.json" } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39874", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39874.json" } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "other", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" } ], "references": [ { "category": "self", "summary": "CVE-2024-39875", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39875.json" } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "other", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" } ], "references": [ { "category": "self", "summary": "CVE-2024-39876", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39876.json" } ], "title": "CVE-2024-39876" }, { "cve": "CVE-2024-39888", "cwe": { "id": "CWE-547", "name": "Use of Hard-coded, Security-relevant Constants" }, "notes": [ { "category": "other", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" } ], "product_status": { "known_affected": [ "CSAFPID-1497113" ] }, "references": [ { "category": "self", "summary": "CVE-2024-39888", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39888.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "CSAFPID-1497113" ] } ], "title": "CVE-2024-39888" }, { "cve": "CVE-2024-3596", "cwe": { "id": "CWE-924", "name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel" }, "notes": [ { "category": "other", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" }, { "category": "other", "text": "Use of Weak Hash", "title": "CWE-328" } ], "references": [ { "category": "self", "summary": "CVE-2024-3596", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-3596.json" } ], "title": "CVE-2024-3596" } ] }
gsd-2022-32260
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-32260", "description": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "id": "GSD-2022-32260" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-32260" ], "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.", "id": "GSD-2022-32260", "modified": "2023-12-13T01:19:12.323408Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-32260", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEMA Remote Connect Server", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-286: Incorrect User Management" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-32260" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2022-06-23T12:53Z", "publishedDate": "2022-06-14T10:15Z" } } }
cnvd-2022-45221
Vulnerability from cnvd
Title: Siemens SINEMA Remote Connect Server用户管理错误漏洞
Description:
SINEMA Remote Connect是一个远程网络管理平台,可轻松管理总部、服务技术人员和已安装机器或工厂之间的隧道连接 (VPN)。
Siemens SINEMA Remote Connect Server存在用户管理错误漏洞,该漏洞源于受影响的应用程序会为 UMC(用户管理组件)用户创建临时用户凭据,攻击者可利用该漏洞使用这些临时凭据绕过身份验证。
Severity: 高
Patch Name: Siemens SINEMA Remote Connect Server用户管理错误漏洞的补丁
Patch Description:
SINEMA Remote Connect是一个远程网络管理平台,可轻松管理总部、服务技术人员和已安装机器或工厂之间的隧道连接 (VPN)。
Siemens SINEMA Remote Connect Server存在用户管理错误漏洞,该漏洞源于受影响的应用程序会为 UMC(用户管理组件)用户创建临时用户凭据,攻击者可利用该漏洞使用这些临时凭据绕过身份验证。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/html/ssa-484086.html
Reference: https://cert-portal.siemens.com/productcert/html/ssa-484086.html
Name | Siemens SINEMA Remote Connect Server <3.1 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-32260" } }, "description": "SINEMA Remote Connect\u662f\u4e00\u4e2a\u8fdc\u7a0b\u7f51\u7edc\u7ba1\u7406\u5e73\u53f0\uff0c\u53ef\u8f7b\u677e\u7ba1\u7406\u603b\u90e8\u3001\u670d\u52a1\u6280\u672f\u4eba\u5458\u548c\u5df2\u5b89\u88c5\u673a\u5668\u6216\u5de5\u5382\u4e4b\u95f4\u7684\u96a7\u9053\u8fde\u63a5 (VPN)\u3002\n\nSiemens SINEMA Remote Connect Server\u5b58\u5728\u7528\u6237\u7ba1\u7406\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u4f1a\u4e3a UMC\uff08\u7528\u6237\u7ba1\u7406\u7ec4\u4ef6\uff09\u7528\u6237\u521b\u5efa\u4e34\u65f6\u7528\u6237\u51ed\u636e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4f7f\u7528\u8fd9\u4e9b\u4e34\u65f6\u51ed\u636e\u7ed5\u8fc7\u8eab\u4efd\u9a8c\u8bc1\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-484086.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-45221", "openTime": "2022-06-15", "patchDescription": "SINEMA Remote Connect\u662f\u4e00\u4e2a\u8fdc\u7a0b\u7f51\u7edc\u7ba1\u7406\u5e73\u53f0\uff0c\u53ef\u8f7b\u677e\u7ba1\u7406\u603b\u90e8\u3001\u670d\u52a1\u6280\u672f\u4eba\u5458\u548c\u5df2\u5b89\u88c5\u673a\u5668\u6216\u5de5\u5382\u4e4b\u95f4\u7684\u96a7\u9053\u8fde\u63a5 (VPN)\u3002\r\n\r\nSiemens SINEMA Remote Connect Server\u5b58\u5728\u7528\u6237\u7ba1\u7406\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u4f1a\u4e3a UMC\uff08\u7528\u6237\u7ba1\u7406\u7ec4\u4ef6\uff09\u7528\u6237\u521b\u5efa\u4e34\u65f6\u7528\u6237\u51ed\u636e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4f7f\u7528\u8fd9\u4e9b\u4e34\u65f6\u51ed\u636e\u7ed5\u8fc7\u8eab\u4efd\u9a8c\u8bc1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SINEMA Remote Connect Server\u7528\u6237\u7ba1\u7406\u9519\u8bef\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Siemens SINEMA Remote Connect Server \u003c3.1" }, "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html", "serverity": "\u9ad8", "submitTime": "2022-06-15", "title": "Siemens SINEMA Remote Connect Server\u7528\u6237\u7ba1\u7406\u9519\u8bef\u6f0f\u6d1e" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.