Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-30774 (GCVE-0-2022-30774)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:56:14.020Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.insyde.com/security-pledge" }, { "tags": [ "x_transferred" ], "url": "https://www.insyde.com/security-pledge/SA-2022043" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2022-30774", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-30T19:12:39.035985Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-367", "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-30T19:13:10.455Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-14T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.insyde.com/security-pledge" }, { "url": "https://www.insyde.com/security-pledge/SA-2022043" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-30774", "datePublished": "2022-11-14T00:00:00.000Z", "dateReserved": "2022-05-16T00:00:00.000Z", "dateUpdated": "2025-04-30T19:13:10.455Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-30774\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-11-15T00:15:09.823\",\"lastModified\":\"2025-04-30T20:15:17.143\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043\"},{\"lang\":\"es\",\"value\":\"Los ataques DMA al b\u00fafer de par\u00e1metros utilizado por el controlador PnpSmm podr\u00edan cambiar el contenido despu\u00e9s de que se hayan verificado los valores de los par\u00e1metros, pero antes de que se utilicen (un ataque TOCTOU). Los ataques DMA al b\u00fafer de par\u00e1metros utilizado por el controlador PnpSmm podr\u00edan cambiar el contenido despu\u00e9s de que se hayan verificado los valores de los par\u00e1metros han sido verificados pero antes de ser utilizados (un ataque TOCTOU). Este problema fue descubierto por la ingenier\u00eda de Insyde durante una revisi\u00f3n de seguridad. Este problema se solucion\u00f3 en Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.5,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.5,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-367\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-367\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.2\",\"versionEndExcluding\":\"5.2.05.27.29\",\"matchCriteriaId\":\"F3AD2F03-B15B-41F0-899F-075A1BD9DF30\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.3\",\"versionEndExcluding\":\"5.3.05.36.25\",\"matchCriteriaId\":\"D80AAA27-6BBB-4476-9A8B-75C838DD3CB3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.4.05.44.25\",\"matchCriteriaId\":\"6F161D09-7811-4B26-914E-C082D86044A4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.5\",\"versionEndExcluding\":\"5.5.05.52.25\",\"matchCriteriaId\":\"9AEA99AC-5827-430B-97AD-35178056390C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.insyde.com/security-pledge\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge/SA-2022043\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.insyde.com/security-pledge\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge/SA-2022043\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.insyde.com/security-pledge\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.insyde.com/security-pledge/SA-2022043\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T06:56:14.020Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-30774\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-30T19:12:39.035985Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-367\", \"description\": \"CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-30T19:12:56.645Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.insyde.com/security-pledge\"}, {\"url\": \"https://www.insyde.com/security-pledge/SA-2022043\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-02-14T00:00:00.000Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-30774\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-30T19:13:10.455Z\", \"dateReserved\": \"2022-05-16T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2022-11-14T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
wid-sec-w-2023-0706
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "InsydeH2O UEFI BIOS ist eine propriet\u00e4re, lizenzierte UEFI-BIOS-Firmware, die Intel und AMD basierte Computer unterst\u00fctzt.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein lokaler Angreifer kann mehrere Schwachstellen in der Insyde UEFI Firmware ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-0706 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-0706.json" }, { "category": "self", "summary": "WID-SEC-2023-0706 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-0706" }, { "category": "external", "summary": "HP Customer Support - Knowledge Base vom 2023-03-21", "url": "https://support.hp.com/us-en/document/ish_7838102-7838162-16/HPSBHF03836" } ], "source_lang": "en-US", "title": "Insyde UEFI Firmware: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-03-21T23:00:00.000+00:00", "generator": { "date": "2024-08-15T17:47:03.228+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-0706", "initial_release_date": "2023-03-21T23:00:00.000+00:00", "revision_history": [ { "date": "2023-03-21T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "HP Computer", "product": { "name": "HP Computer", "product_id": "T023191", "product_identification_helper": { "cpe": "cpe:/h:hp:computer:-" } } } ], "category": "vendor", "name": "HP" }, { "branches": [ { "category": "product_name", "name": "Insyde UEFI Firmware", "product": { "name": "Insyde UEFI Firmware", "product_id": "T026843", "product_identification_helper": { "cpe": "cpe:/h:insyde:uefi:-" } } } ], "category": "vendor", "name": "Insyde" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-34325", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-34325" }, { "cve": "CVE-2022-33986", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33986" }, { "cve": "CVE-2022-33985", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33985" }, { "cve": "CVE-2022-33984", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33984" }, { "cve": "CVE-2022-33983", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33983" }, { "cve": "CVE-2022-33982", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33982" }, { "cve": "CVE-2022-33909", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33909" }, { "cve": "CVE-2022-33908", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33908" }, { "cve": "CVE-2022-33907", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33907" }, { "cve": "CVE-2022-33906", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33906" }, { "cve": "CVE-2022-33905", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33905" }, { "cve": "CVE-2022-32267", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-32267" }, { "cve": "CVE-2022-32266", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-32266" }, { "cve": "CVE-2022-31243", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-31243" }, { "cve": "CVE-2022-30774", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-30774" }, { "cve": "CVE-2022-30773", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-30773" } ] }
WID-SEC-W-2023-0706
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "InsydeH2O UEFI BIOS ist eine propriet\u00e4re, lizenzierte UEFI-BIOS-Firmware, die Intel und AMD basierte Computer unterst\u00fctzt.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein lokaler Angreifer kann mehrere Schwachstellen in der Insyde UEFI Firmware ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-0706 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-0706.json" }, { "category": "self", "summary": "WID-SEC-2023-0706 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-0706" }, { "category": "external", "summary": "HP Customer Support - Knowledge Base vom 2023-03-21", "url": "https://support.hp.com/us-en/document/ish_7838102-7838162-16/HPSBHF03836" } ], "source_lang": "en-US", "title": "Insyde UEFI Firmware: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-03-21T23:00:00.000+00:00", "generator": { "date": "2024-08-15T17:47:03.228+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-0706", "initial_release_date": "2023-03-21T23:00:00.000+00:00", "revision_history": [ { "date": "2023-03-21T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "HP Computer", "product": { "name": "HP Computer", "product_id": "T023191", "product_identification_helper": { "cpe": "cpe:/h:hp:computer:-" } } } ], "category": "vendor", "name": "HP" }, { "branches": [ { "category": "product_name", "name": "Insyde UEFI Firmware", "product": { "name": "Insyde UEFI Firmware", "product_id": "T026843", "product_identification_helper": { "cpe": "cpe:/h:insyde:uefi:-" } } } ], "category": "vendor", "name": "Insyde" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-34325", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-34325" }, { "cve": "CVE-2022-33986", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33986" }, { "cve": "CVE-2022-33985", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33985" }, { "cve": "CVE-2022-33984", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33984" }, { "cve": "CVE-2022-33983", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33983" }, { "cve": "CVE-2022-33982", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33982" }, { "cve": "CVE-2022-33909", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33909" }, { "cve": "CVE-2022-33908", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33908" }, { "cve": "CVE-2022-33907", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33907" }, { "cve": "CVE-2022-33906", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33906" }, { "cve": "CVE-2022-33905", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-33905" }, { "cve": "CVE-2022-32267", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-32267" }, { "cve": "CVE-2022-32266", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-32266" }, { "cve": "CVE-2022-31243", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-31243" }, { "cve": "CVE-2022-30774", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-30774" }, { "cve": "CVE-2022-30773", "notes": [ { "category": "description", "text": "In der Insyde UEFI Firmware existieren mehrere \"Time-of-Check to Time-of-Use (TOCTOU)\" Schwachstellen. Ein lokaler Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Informationen offenzulegen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T023191", "T026843" ] }, "release_date": "2023-03-21T23:00:00.000+00:00", "title": "CVE-2022-30773" } ] }
CERTFR-2023-AVI-0121
Vulnerability from certfr_avis
De multiples vulnérabilités ont été corrigées dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | JT Utilities versions antérieures à V13.2.3.0 | ||
Siemens | N/A | Parasolid V35.0 versions antérieures à V35.0.170 | ||
Siemens | N/A | TIA Project-Server versions antérieures à V1.1 | ||
Siemens | N/A | COMOS V10.3.3.4 versions antérieures à V10.3.3.4.6 | ||
Siemens | N/A | SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Parasolid V34.1 versions antérieures à V34.1.242 | ||
Siemens | N/A | TIA Multiuser Server V16 toutes les versions | ||
Siemens | N/A | COMOS V10.2 toutes les versions | ||
Siemens | N/A | Simcenter Femap versions antérieures à V2023.1 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.12) antérieures à V9.12.10 | ||
Siemens | N/A | Parasolid V35.1 versions antérieures à V35.1.150 | ||
Siemens | N/A | COMOS V10.3.3.3 versions antérieures à V10.3.3.3.9 | ||
Siemens | N/A | SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions antérieures à V5.5.0 | ||
Siemens | N/A | Brownfield Connectivity - Client versions antérieures à V2.15 | ||
Siemens | N/A | COMOS V10.4.2.0 versions antérieures à V10.4.2.0.25 | ||
Siemens | N/A | TIA Multiuser Server V14 toutes les versions | ||
Siemens | N/A | COMOS V10.3.3.1 versions antérieures à V10.3.3.1.45 | ||
Siemens | N/A | Parasolid V34.0 versions antérieures à V34.0.254 | ||
Siemens | N/A | SiPass integrated AC5102 (ACC-G2) versions antérieures à V2.85.44 | ||
Siemens | N/A | Solid Edge SE2023 versions antérieures à V2023Update2 | ||
Siemens | N/A | SiPass integrated ACC-AP versions antérieures à V2.85.43 | ||
Siemens | N/A | SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | COMOS V10.4.0.0 versions antérieures à V10.4.0.0.31 | ||
Siemens | N/A | Applications utilisant Mendix versions 7 antérieures à V7.23.34 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.18) antérieures à V9.18.4 | ||
Siemens | N/A | SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | TIA Multiuser Server V15 versions antérieures à V15.1 Update 8 | ||
Siemens | N/A | SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 8 antérieures à V8.18.23 | ||
Siemens | N/A | Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions | ||
Siemens | N/A | SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Brownfield Connectivity - Gateway versions antérieures à V1.11 | ||
Siemens | N/A | SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | TIA Multiuser Server V17 toutes les versions | ||
Siemens | N/A | Famille de produits RUGGEDCOM APE1808 toutes les versions | ||
Siemens | N/A | SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.6) antérieures à V9.6.15 | ||
Siemens | N/A | COMOS V10.4.1.0 versions antérieures à V10.4.1.0.32 | ||
Siemens | N/A | SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | COMOS V10.3.3.2 versions antérieures à V10.3.3.2.33 | ||
Siemens | N/A | Tecnomatix Plant Simulation versions antérieures à V2201.0006 | ||
Siemens | N/A | JT Open versions antérieures à V11.2.3.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 antérieures à V9.22.0 |
Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "JT Utilities versions ant\u00e9rieures \u00e0 V13.2.3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V35.0 versions ant\u00e9rieures \u00e0 V35.0.170", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Project-Server versions ant\u00e9rieures \u00e0 V1.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.4 versions ant\u00e9rieures \u00e0 V10.3.3.4.6", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.1 versions ant\u00e9rieures \u00e0 V34.1.242", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V16 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.2 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2023.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.12) ant\u00e9rieures \u00e0 V9.12.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V35.1 versions ant\u00e9rieures \u00e0 V35.1.150", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.3 versions ant\u00e9rieures \u00e0 V10.3.3.3.9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Brownfield Connectivity - Client versions ant\u00e9rieures \u00e0 V2.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.2.0 versions ant\u00e9rieures \u00e0 V10.4.2.0.25", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V14 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.1 versions ant\u00e9rieures \u00e0 V10.3.3.1.45", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.0 versions ant\u00e9rieures \u00e0 V34.0.254", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SiPass integrated AC5102 (ACC-G2) versions ant\u00e9rieures \u00e0 V2.85.44", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 V2023Update2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SiPass integrated ACC-AP versions ant\u00e9rieures \u00e0 V2.85.43", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.0.0 versions ant\u00e9rieures \u00e0 V10.4.0.0.31", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 7 ant\u00e9rieures \u00e0 V7.23.34", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.18) ant\u00e9rieures \u00e0 V9.18.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V15 versions ant\u00e9rieures \u00e0 V15.1 Update 8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 8 ant\u00e9rieures \u00e0 V8.18.23", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Brownfield Connectivity - Gateway versions ant\u00e9rieures \u00e0 V1.11", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V17 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Famille de produits RUGGEDCOM APE1808 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.6) ant\u00e9rieures \u00e0 V9.6.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.1.0 versions ant\u00e9rieures \u00e0 V10.4.1.0.32", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.2 versions ant\u00e9rieures \u00e0 V10.3.3.2.33", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Tecnomatix Plant Simulation versions ant\u00e9rieures \u00e0 V2201.0006", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT Open versions ant\u00e9rieures \u00e0 V11.2.3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 ant\u00e9rieures \u00e0 V9.22.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2023-24556", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24556" }, { "name": "CVE-2022-1343", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1343" }, { "name": "CVE-2022-1473", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1473" }, { "name": "CVE-2023-24990", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24990" }, { "name": "CVE-2022-39157", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39157" }, { "name": "CVE-2022-46345", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46345" }, { "name": "CVE-2023-22669", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22669" }, { "name": "CVE-2023-24549", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24549" }, { "name": "CVE-2023-24560", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24560" }, { "name": "CVE-2022-31808", "url": "https://www.cve.org/CVERecord?id=CVE-2022-31808" }, { "name": "CVE-2022-46347", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46347" }, { "name": "CVE-2022-27536", "url": "https://www.cve.org/CVERecord?id=CVE-2022-27536" }, { "name": "CVE-2022-46349", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46349" }, { "name": "CVE-2022-24921", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24921" }, { "name": "CVE-2022-28327", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28327" }, { "name": "CVE-2022-1292", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1292" }, { "name": "CVE-2023-24552", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24552" }, { "name": "CVE-2021-43391", "url": "https://www.cve.org/CVERecord?id=CVE-2021-43391" }, { "name": "CVE-2023-24980", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24980" }, { "name": "CVE-2021-32936", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "name": "CVE-2022-33984", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33984" }, { "name": "CVE-2023-24551", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24551" }, { "name": "CVE-2022-46346", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46346" }, { "name": "CVE-2023-24992", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24992" }, { "name": "CVE-2022-21198", "url": "https://www.cve.org/CVERecord?id=CVE-2022-21198" }, { "name": "CVE-2007-5846", "url": "https://www.cve.org/CVERecord?id=CVE-2007-5846" }, { "name": "CVE-2022-33906", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33906" }, { "name": "CVE-2023-24562", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24562" }, { "name": "CVE-2023-24482", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24482" }, { "name": "CVE-2023-24994", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24994" }, { "name": "CVE-2021-41771", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41771" }, { "name": "CVE-2022-43397", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43397" }, { "name": "CVE-2023-24561", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24561" }, { "name": "CVE-2023-24995", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24995" }, { "name": "CVE-2022-30774", "url": "https://www.cve.org/CVERecord?id=CVE-2022-30774" }, { "name": "CVE-2023-24553", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24553" }, { "name": "CVE-2023-24984", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24984" }, { "name": "CVE-2021-32938", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "name": "CVE-2023-24993", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24993" }, { "name": "CVE-2023-24558", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24558" }, { "name": "CVE-2022-46348", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46348" }, { "name": "CVE-2023-22295", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22295" }, { "name": "CVE-2021-32948", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "name": "CVE-2022-33982", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33982" }, { "name": "CVE-2023-22846", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22846" }, { "name": "CVE-2023-24983", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24983" }, { "name": "CVE-2022-47936", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47936" }, { "name": "CVE-2022-47977", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47977" }, { "name": "CVE-2023-24550", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24550" }, { "name": "CVE-2023-24565", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24565" }, { "name": "CVE-2023-25140", "url": "https://www.cve.org/CVERecord?id=CVE-2023-25140" }, { "name": "CVE-2023-24988", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24988" }, { "name": "CVE-2022-35868", "url": "https://www.cve.org/CVERecord?id=CVE-2022-35868" }, { "name": "CVE-2023-24554", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24554" }, { "name": "CVE-2022-33907", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33907" }, { "name": "CVE-2021-43336", "url": "https://www.cve.org/CVERecord?id=CVE-2021-43336" }, { "name": "CVE-2023-24581", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24581" }, { "name": "CVE-2023-22321", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22321" }, { "name": "CVE-2022-24675", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24675" }, { "name": "CVE-2023-24557", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24557" }, { "name": "CVE-2023-24566", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24566" }, { "name": "CVE-2023-24978", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24978" }, { "name": "CVE-2023-24555", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24555" }, { "name": "CVE-2023-24979", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24979" }, { "name": "CVE-2023-22354", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22354" }, { "name": "CVE-2021-41772", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41772" }, { "name": "CVE-2023-24987", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24987" }, { "name": "CVE-2023-24986", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24986" }, { "name": "CVE-2021-44716", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44716" }, { "name": "CVE-2023-23579", "url": "https://www.cve.org/CVERecord?id=CVE-2023-23579" }, { "name": "CVE-2023-24564", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24564" }, { "name": "CVE-2023-24982", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24982" }, { "name": "CVE-2023-24996", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24996" }, { "name": "CVE-2022-31243", "url": "https://www.cve.org/CVERecord?id=CVE-2022-31243" }, { "name": "CVE-2023-24563", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24563" }, { "name": "CVE-2023-24985", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24985" }, { "name": "CVE-2023-24991", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24991" }, { "name": "CVE-2023-24981", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24981" }, { "name": "CVE-2021-44717", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44717" }, { "name": "CVE-2022-1434", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1434" }, { "name": "CVE-2022-33908", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33908" }, { "name": "CVE-2023-23835", "url": "https://www.cve.org/CVERecord?id=CVE-2023-23835" }, { "name": "CVE-2023-24559", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24559" }, { "name": "CVE-2023-24989", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24989" }, { "name": "CVE-2023-22670", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22670" } ], "initial_release_date": "2023-02-14T00:00:00", "last_revision_date": "2023-02-14T00:00:00", "links": [ { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-953464.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617755.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-658793.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686975.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-744259.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693110.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf" } ], "reference": "CERTFR-2023-AVI-0121", "revisions": [ { "description": "Version initiale", "revision_date": "2023-02-14T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un\nd\u00e9ni de service \u00e0 distance et un contournement de la politique de\ns\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-847261 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-693110 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-953464 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-744259 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-617755 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-658793 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-450613 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-491245 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-686975 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-836777 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-565356 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-252808 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-640968 du 14 f\u00e9vrier 2023", "url": null } ] }
fkie_cve-2022-30774
Vulnerability from fkie_nvd
6.4 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
URL | Tags | ||
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf | ||
cve@mitre.org | https://www.insyde.com/security-pledge | Vendor Advisory | |
cve@mitre.org | https://www.insyde.com/security-pledge/SA-2022043 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.insyde.com/security-pledge/SA-2022043 | Vendor Advisory |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3AD2F03-B15B-41F0-899F-075A1BD9DF30", "versionEndExcluding": "5.2.05.27.29", "versionStartIncluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "matchCriteriaId": "D80AAA27-6BBB-4476-9A8B-75C838DD3CB3", "versionEndExcluding": "5.3.05.36.25", "versionStartIncluding": "5.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F161D09-7811-4B26-914E-C082D86044A4", "versionEndExcluding": "5.4.05.44.25", "versionStartIncluding": "5.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "matchCriteriaId": "9AEA99AC-5827-430B-97AD-35178056390C", "versionEndExcluding": "5.5.05.52.25", "versionStartIncluding": "5.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043" }, { "lang": "es", "value": "Los ataques DMA al b\u00fafer de par\u00e1metros utilizado por el controlador PnpSmm podr\u00edan cambiar el contenido despu\u00e9s de que se hayan verificado los valores de los par\u00e1metros, pero antes de que se utilicen (un ataque TOCTOU). Los ataques DMA al b\u00fafer de par\u00e1metros utilizado por el controlador PnpSmm podr\u00edan cambiar el contenido despu\u00e9s de que se hayan verificado los valores de los par\u00e1metros han sido verificados pero antes de ser utilizados (un ataque TOCTOU). Este problema fue descubierto por la ingenier\u00eda de Insyde durante una revisi\u00f3n de seguridad. Este problema se solucion\u00f3 en Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043" } ], "id": "CVE-2022-30774", "lastModified": "2025-04-30T20:15:17.143", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2022-11-15T00:15:09.823", "references": [ { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022043" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022043" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-367" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-367" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
ghsa-5529-988r-7c93
Vulnerability from github
DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043
{ "affected": [], "aliases": [ "CVE-2022-30774" ], "database_specific": { "cwe_ids": [ "CWE-367" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-11-15T00:15:00Z", "severity": "MODERATE" }, "details": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043", "id": "GHSA-5529-988r-7c93", "modified": "2022-11-18T18:30:25Z", "published": "2022-11-15T12:00:16Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-30774" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "type": "WEB", "url": "https://www.insyde.com/security-pledge" }, { "type": "WEB", "url": "https://www.insyde.com/security-pledge/SA-2022043" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
cnvd-2023-09128
Vulnerability from cnvd
目前没有详细解决方案提供: https://new.siemens.com/cn/zh.html
Name | ['Siemens RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)', 'Siemens RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)', 'Siemens RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)', 'Siemens RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)', 'Siemens RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)', 'Siemens RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)', 'Siemens RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)', 'Siemens RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)', 'Siemens RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)', 'Siemens RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)', 'Siemens RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)', 'Siemens RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)', 'Siemens RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)', 'Siemens RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)', 'Siemens RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)', 'Siemens RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)', 'Siemens RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)', 'Siemens RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)', 'Siemens RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)', 'Siemens RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)', 'Siemens RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)', 'Siemens RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-30774" } }, "description": "RUGGEDCOM APE1808\u662f\u4e00\u4e2a\u5b9e\u7528\u7a0b\u5e8f\u7ea7\u5e94\u7528\u7a0b\u5e8f\u6258\u7ba1\u5e73\u53f0\uff0c\u5141\u8bb8\u60a8\u5728\u6076\u52a3\u7684\u5de5\u4e1a\u73af\u5883\u4e2d\u90e8\u7f72\u4e00\u7cfb\u5217\u7528\u4e8e\u8fb9\u7f18\u8ba1\u7b97\u548c\u7f51\u7edc\u5b89\u5168\u7684\u5546\u7528\u5e94\u7528\u7a0b\u5e8f\u3002\n\nSiemens RUGGEDCOM APE1808\u4ea7\u54c1\u7cfb\u5217\u5b58\u5728\u7ade\u4e89\u6761\u4ef6\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u68c0\u67e5\u53c2\u6570\u503c\u4e4b\u540e\u4f46\u5728\u4f7f\u7528\u4e4b\u524d\u66f4\u6539\u5185\u5bb9\uff08TOCTOU\u653b\u51fb\uff09\u3002", "formalWay": "\u76ee\u524d\u6ca1\u6709\u8be6\u7ec6\u89e3\u51b3\u65b9\u6848\u63d0\u4f9b\uff1a\r\nhttps://new.siemens.com/cn/zh.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2023-09128", "openTime": "2023-02-15", "products": { "product": [ "Siemens RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)", "Siemens RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)", "Siemens RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)", "Siemens RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)", "Siemens RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)", "Siemens RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)", "Siemens RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)", "Siemens RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)", "Siemens RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)", "Siemens RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)", "Siemens RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)", "Siemens RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)", "Siemens RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)", "Siemens RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)", "Siemens RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)", "Siemens RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)", "Siemens RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)", "Siemens RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)", "Siemens RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)", "Siemens RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)", "Siemens RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)", "Siemens RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-450613.html", "serverity": "\u4e2d", "submitTime": "2023-02-14", "title": "Siemens RUGGEDCOM APE1808\u4ea7\u54c1\u7cfb\u5217\u7ade\u4e89\u6761\u4ef6\u6f0f\u6d1e" }
gsd-2022-30774
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-30774", "id": "GSD-2022-30774" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-30774" ], "details": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043", "id": "GSD-2022-30774", "modified": "2023-12-13T01:19:36.848510Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-30774", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022043", "refsource": "MISC", "url": "https://www.insyde.com/security-pledge/SA-2022043" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.3.05.36.25", "versionStartIncluding": "5.3", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.4.05.44.25", "versionStartIncluding": "5.4", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.5.05.52.25", "versionStartIncluding": "5.5", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:insyde:kernel:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2.05.27.29", "versionStartIncluding": "5.2", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-30774" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack) . This issue was discovered by Insyde engineering during a security review. This iss was fixed in Kernel 5.2: 05.27.29, Kernel 5.3: 05.36.25, Kernel 5.4: 05.44.25, Kernel 5.5: 05.52.25. CWE-367 https://www.insyde.com/security-pledge/SA-2022043" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-367" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.insyde.com/security-pledge", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge" }, { "name": "https://www.insyde.com/security-pledge/SA-2022043", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.insyde.com/security-pledge/SA-2022043" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 5.9 } }, "lastModifiedDate": "2023-02-14T12:15Z", "publishedDate": "2022-11-15T00:15Z" } } }
icsa-23-047-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Insyde has published information on vulnerabilities in Insyde BIOS on \nNovember 8th 2022. These vulnerabilities also affect the RUGGEDCOM APE1808 product family.\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-450613.json" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-450613.html" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-450613.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-08 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM APE1808", "tracking": { "current_release_date": "2023-09-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-08", "initial_release_date": "2023-02-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-02-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-09-12T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added remediation for affected products and removed CVE-2022-33907 as the products are not affected" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GL0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GL1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GK0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GK1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GM0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GM1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GP0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GP1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GN0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)", "product_id": "CSAFPID-0010", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GN1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)", "product_id": "CSAFPID-0011", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AA0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)", "product_id": "CSAFPID-0012", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AA1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)", "product_id": "CSAFPID-0013", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AB0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)", "product_id": "CSAFPID-0014", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AB1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)", "product_id": "CSAFPID-0015", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AD0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)", "product_id": "CSAFPID-0016", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AD1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)", "product_id": "CSAFPID-0017", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AF0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)", "product_id": "CSAFPID-0018", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AF1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)", "product_id": "CSAFPID-0019", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GH0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)", "product_id": "CSAFPID-0020", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GH1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)", "product_id": "CSAFPID-0021", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GJ0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)", "product_id": "CSAFPID-0022", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GJ1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-30774", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack). This issue was discovered by Insyde engineering during a security review. https://www.insyde.com/security-pledge/SA-2022043", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-30774" }, { "cve": "CVE-2022-31243", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "Update description and links DMA transactions which are targeted at input buffers used for the software SMI handler used by the FvbServicesRuntimeDxe driver could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022044", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-31243" }, { "cve": "CVE-2022-33906", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the FwBlockServiceSmm software SMI handler could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022048", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33906" }, { "cve": "CVE-2022-33908", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the SdHostDriver software SMI handler could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022050", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33908" }, { "cve": "CVE-2022-33982", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA attacks on the parameter buffer used by the Int15ServiceSmm software SMI handler could lead to a TOCTOU attack on the SMI handler and lead to corruption of SMRAM. \r\nThis issue was discovered by Insyde engineering during a security review.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33982" }, { "cve": "CVE-2022-33984", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the SdMmcDevice software SMI handler could cause SMRAM corruption through a TOCTOU attack. \r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022054", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33984" } ] }
ICSA-23-047-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Insyde has published information on vulnerabilities in Insyde BIOS on \nNovember 8th 2022. These vulnerabilities also affect the RUGGEDCOM APE1808 product family.\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-450613.json" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-450613.html" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "category": "self", "summary": "SSA-450613: Insyde BIOS Vulnerabilities in RUGGEDCOM APE1808 Product Family - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-450613.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-08 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM APE1808", "tracking": { "current_release_date": "2023-09-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-08", "initial_release_date": "2023-02-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-02-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-09-12T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added remediation for affected products and removed CVE-2022-33907 as the products are not affected" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GL0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GL1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GK0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GK1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GM0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GM1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GP0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GP1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GN0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)", "product_id": "CSAFPID-0010", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GN1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)", "product_id": "CSAFPID-0011", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AA0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)", "product_id": "CSAFPID-0012", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AA1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)", "product_id": "CSAFPID-0013", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AB0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)", "product_id": "CSAFPID-0014", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AB1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)", "product_id": "CSAFPID-0015", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AD0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)", "product_id": "CSAFPID-0016", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AD1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)", "product_id": "CSAFPID-0017", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AF0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)", "product_id": "CSAFPID-0018", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-1AF1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)", "product_id": "CSAFPID-0019", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GH0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)", "product_id": "CSAFPID-0020", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GH1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)", "product_id": "CSAFPID-0021", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GJ0" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cBIOS_V1.0.212N", "product": { "name": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)", "product_id": "CSAFPID-0022", "product_identification_helper": { "model_numbers": [ "6GK6015-0AL20-0GJ1" ] } } } ], "category": "product_name", "name": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-30774", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA attacks on the parameter buffer used by the PnpSmm driver could change the contents after parameter values have been checked but before they are used (a TOCTOU attack). This issue was discovered by Insyde engineering during a security review. https://www.insyde.com/security-pledge/SA-2022043", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-30774" }, { "cve": "CVE-2022-31243", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "Update description and links DMA transactions which are targeted at input buffers used for the software SMI handler used by the FvbServicesRuntimeDxe driver could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022044", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-31243" }, { "cve": "CVE-2022-33906", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the FwBlockServiceSmm software SMI handler could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022048", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33906" }, { "cve": "CVE-2022-33908", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the SdHostDriver software SMI handler could cause SMRAM corruption through a TOCTOU attack.\r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022050", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33908" }, { "cve": "CVE-2022-33982", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA attacks on the parameter buffer used by the Int15ServiceSmm software SMI handler could lead to a TOCTOU attack on the SMI handler and lead to corruption of SMRAM. \r\nThis issue was discovered by Insyde engineering during a security review.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33982" }, { "cve": "CVE-2022-33984", "cwe": { "id": "CWE-367", "name": "Time-of-check Time-of-use (TOCTOU) Race Condition" }, "notes": [ { "category": "summary", "text": "DMA transactions which are targeted at input buffers used for the SdMmcDevice software SMI handler could cause SMRAM corruption through a TOCTOU attack. \r\nThis issue was discovered by Insyde engineering based on the general description provided by Intel\u0027s iSTARE group. https://www.insyde.com/security-pledge/SA-2022054", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update BIOS to V1.0.212N or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://support.industry.siemens.com/cs/in/en/view/109814796" } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ], "title": "CVE-2022-33984" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.