cve-2022-27241
Vulnerability from cvelistv5
Published
2022-04-12 09:08
Modified
2024-08-03 05:25
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Mendix Applications using Mendix 7 |
Version: All versions < V7.23.31 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:25:32.284Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.31" } ] }, { "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.18" } ] }, { "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.11" } ] }, { "product": "Mendix Applications using Mendix 9 (V9.6)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.6.12" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:37", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-27241", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mendix Applications using Mendix 7", "version": { "version_data": [ { "version_value": "All versions \u003c V7.23.31" } ] } }, { "product_name": "Mendix Applications using Mendix 8", "version": { "version_data": [ { "version_value": "All versions \u003c V8.18.18" } ] } }, { "product_name": "Mendix Applications using Mendix 9", "version": { "version_data": [ { "version_value": "All versions \u003c V9.11" } ] } }, { "product_name": "Mendix Applications using Mendix 9 (V9.6)", "version": { "version_data": [ { "version_value": "All versions \u003c V9.6.12" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-27241", "datePublished": "2022-04-12T09:08:00", "dateReserved": "2022-03-18T00:00:00", "dateUpdated": "2024-08-03T05:25:32.284Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-27241\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:15.060\",\"lastModified\":\"2024-11-21T06:55:28.807\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix que utilizan Mendix 7 (Todas las versiones anteriores a la versi\u00f3n V7.23.31), las aplicaciones de Mendix que utilizan Mendix 8 (Todas las versiones anteriores a la versi\u00f3n V8.18.18), las aplicaciones de Mendix que utilizan Mendix 9 (Todas las versiones anteriores a la versi\u00f3n V9.11), las aplicaciones de Mendix que utilizan Mendix 9 (V9.6) (Todas las versiones anteriores a la versi\u00f3n V9.6.12). Las aplicaciones construidas con un sistema afectado exponen p\u00fablicamente la estructura interna del proyecto. Esto podr\u00eda permitir a un atacante remoto no autentificado leer informaci\u00f3n confidencial\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndExcluding\":\"9.11.0\",\"matchCriteriaId\":\"DC850CB1-4E44-4D38-90E2-48CA73A979A4\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.