Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Energy Manager Basic |
Version: All versions < V7.3 Update 1 |
||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T03:43:45.944Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC Energy Manager Basic", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V7.3 Update 1", }, ], }, { product: "SIMATIC Energy Manager PRO", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V7.3 Update 1", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-732", description: "CWE-732: Incorrect Permission Assignment for Critical Resource", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2022-04-12T09:07:35", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2022-23448", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC Energy Manager Basic", version: { version_data: [ { version_value: "All versions < V7.3 Update 1", }, ], }, }, { product_name: "SIMATIC Energy Manager PRO", version: { version_data: [ { version_value: "All versions < V7.3 Update 1", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-732: Incorrect Permission Assignment for Critical Resource", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-23448", datePublished: "2022-04-12T09:07:35", dateReserved: "2022-01-19T00:00:00", dateUpdated: "2024-08-03T03:43:45.944Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2022-23448\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:14.233\",\"lastModified\":\"2024-11-21T06:48:34.530\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Las aplicaciones afectadas asignan inapropiadamente los permisos a directorios y archivos críticos usados por los procesos de la aplicación. Esto podría permitir a un atacante local no privilegiado lograr la ejecución de código con privilegios de ADMINISTRADOR o incluso de NT AUTHORITY/SYSTEM\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.3\",\"matchCriteriaId\":\"2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.3\",\"matchCriteriaId\":\"4B1E608C-3C6F-45FB-86C9-E99E7F21836D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.