cve-2022-20918
Vulnerability from cvelistv5
Published
2022-11-10 17:29
Modified
2024-08-03 02:31
Severity ?
EPSS score ?
Summary
A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.
This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.
This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Cisco | Cisco Firepower Management Center |
Version: 7.0.0 Version: 7.0.0.1 Version: 7.0.1 Version: 7.0.1.1 Version: 7.0.2 Version: 7.0.2.1 Version: 7.0.3 Version: 7.0.4 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T02:31:57.397Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "cisco-sa-fmcsfr-snmp-access-6gqgtJ4S", "tags": [ "x_transferred" ], "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcsfr-snmp-access-6gqgtJ4S" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Cisco Firepower Management Center", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "7.0.0" }, { "status": "affected", "version": "7.0.0.1" }, { "status": "affected", "version": "7.0.1" }, { "status": "affected", "version": "7.0.1.1" }, { "status": "affected", "version": "7.0.2" }, { "status": "affected", "version": "7.0.2.1" }, { "status": "affected", "version": "7.0.3" }, { "status": "affected", "version": "7.0.4" } ] }, { "product": "Cisco FirePOWER Services Software for ASA", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "N/A" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.\r\n\r This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.\r\n\r This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed." } ], "exploits": [ { "lang": "en", "value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "cvssV3_1" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "Improper Access Control", "lang": "en", "type": "cwe" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-25T16:57:13.186Z", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "cisco-sa-fmcsfr-snmp-access-6gqgtJ4S", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcsfr-snmp-access-6gqgtJ4S" } ], "source": { "advisory": "cisco-sa-fmcsfr-snmp-access-6gqgtJ4S", "defects": [ "CSCwa97541" ], "discovery": "EXTERNAL" } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2022-20918", "datePublished": "2022-11-10T17:29:53.489Z", "dateReserved": "2021-11-02T13:28:29.189Z", "dateUpdated": "2024-08-03T02:31:57.397Z", "requesterUserId": "4087f8c1-b21c-479b-99df-de23cb76b743", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-20918\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2022-11-15T21:15:29.820\",\"lastModified\":\"2024-11-26T16:09:02.407\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.\\r\\n\\r This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.\\r\\n\\r This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en Simple Network Management Protocol (SNMP) para el m\u00f3dulo FirePOWER con control de acceso para Cisco FirePOWER Software para Adaptive Security Appliance (ASA), el software Cisco Firepower Management Center (FMC) y el software Cisco Next-Generation Intrusion Prevention System (NGIPS) podr\u00eda permitir un atacante remoto no autenticado realice una solicitud GET SNMP utilizando una credencial predeterminada. Esta vulnerabilidad se debe a la presencia de una credencial predeterminada para SNMP versi\u00f3n 1 (SNMPv1) y SNMP versi\u00f3n 2 (SNMPv2). Un atacante podr\u00eda aprovechar esta vulnerabilidad enviando una solicitud GET SNMPv1 o SNMPv2 a un dispositivo afectado. Un exploit exitoso podr\u00eda permitir al atacante recuperar informaci\u00f3n confidencial del dispositivo utilizando la credencial predeterminada. Este ataque s\u00f3lo tendr\u00e1 \u00e9xito si se configura SNMP y el atacante s\u00f3lo puede realizar solicitudes GET de SNMP; No se permite el acceso de escritura mediante SNMP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_services_software_for_asa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4C5EF69-498C-4433-8B86-91EB343C3F63\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndExcluding\":\"7.0.5\",\"matchCriteriaId\":\"A1ED1366-633E-42A7-8EB7-65F1AA919FBA\"}]}]}],\"references\":[{\"url\":\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcsfr-snmp-access-6gqgtJ4S\",\"source\":\"ykramarz@cisco.com\"},{\"url\":\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcsfr-snmp-access-6gqgtJ4S\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.