Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-41535 (GCVE-0-2021-41535)
Vulnerability from cvelistv5
- CWE-416 - Use After Free
URL | Tags | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Siemens | NX 1953 Series |
Version: All versions < V1973.3700 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:15:28.435Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NX 1953 Series", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1973.3700" } ] }, { "product": "NX 1980 Series", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1988" } ] }, { "product": "Solid Edge SE2021", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c SE2021MP8" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-09T11:32:11", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-41535", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NX 1953 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1973.3700" } ] } }, { "product_name": "NX 1980 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1988" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All versions \u003c SE2021MP8" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416: Use After Free" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-41535", "datePublished": "2021-09-28T11:12:29", "dateReserved": "2021-09-21T00:00:00", "dateUpdated": "2024-08-04T03:15:28.435Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-41535\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-09-28T12:15:08.093\",\"lastModified\":\"2024-11-21T06:26:22.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en NX 1953 Series (Todas las versiones anteriores a V1973.3700), NX 1980 Series (Todas las versiones anteriores a V1988), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). La aplicaci\u00f3n afectada contiene una vulnerabilidad de uso despu\u00e9s de libre al analizar archivos OBJ. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual (ZDI-CAN-13771)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2021\",\"matchCriteriaId\":\"576A303A-66CA-4694-AA54-9EB0137C24F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"82090774-D894-41C8-82F1-A48A8707E9BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4173D09-C317-45FF-ABA4-39E5592862F8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1984_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1984\",\"matchCriteriaId\":\"9A7DCD3A-4441-4E9C-AE47-24098F07DED7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1984:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56F1E031-1413-4DE0-8F05-DE1A9386420A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1988_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1984\",\"matchCriteriaId\":\"6C8E5152-5B4A-4290-AED1-3687C6B0AA3E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1988:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC5E1959-9A7C-4952-A3D7-AA36E9E6FAE8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1957_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1973.3700\",\"matchCriteriaId\":\"A2522E4B-461C-4D62-B050-99DB97D6B292\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1957:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5AC59921-B54E-4FCD-9759-79798F9482E5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1961_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1973.3700\",\"matchCriteriaId\":\"9DA28584-9BB3-4548-972F-0E72A20912F7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1961:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D6529FE-F172-430A-8157-647D624C08E9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1965_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1973.3700\",\"matchCriteriaId\":\"FA9C5704-F07E-4CC2-B580-D9D8C3A83CCB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1965:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0BF4B7E-D26F-4D94-AD87-DDB67DD95450\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:nx_1969_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1973.3700\",\"matchCriteriaId\":\"8E752A21-139F-4A78-BECA-6C2E33007E00\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:nx_1969:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A7965A5-E980-4044-A554-0E187883900E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-1119/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-1119/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
ICSA-21-315-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens NX is affected by two vulnerabilities that could be triggered when the application reads OBJ files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system.\n\nSiemens has released updates for the NX and recommends to update to the latest version. Siemens recommends to avoid opening of untrusted files from unknown sources.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-328042.json" }, { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-328042.txt" }, { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-08 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens NX OBJ Translator", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-08", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1973.3700", "product": { "name": "NX 1953 Series", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "NX 1953 Series" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1988", "product": { "name": "NX 1980 Series", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "NX 1980 Series" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-41535", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-41535 - NX 1953 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41535 - NX 1980 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41535 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41535.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1973.3700 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V1988 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-41535" }, { "cve": "CVE-2021-41538", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.\n\nAn attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-41538 - NX 1953 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41538 - NX 1980 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41538 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41538.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1973.3700 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V1988 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-41538" } ] }
ICSA-21-287-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "names": [ "xina1i" ], "summary": "reporting vulnerabilities CVE-2021-37202 and CVE-2021-37203" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure of CVE-2021-41533 through CVE-2021-41540" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released a new version for Solid Edge that fixes multiple file parsing vulnerabilities which could be triggered when the application reads files in IFC, JT or OBJ formats.\n\nIf a user is tricked to opening a malicious file using the affected application this could lead the application to crash, or potentially arbitrary code execution on the target host system.\n\nSiemens recommends to update to the latest version and to limit opening of files from unknown sources in the affected products.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-728618.json" }, { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-728618.txt" }, { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-287-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-287-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-287-06", "initial_release_date": "2021-09-28T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-28T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cSE2021MP8", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Solid Edge SE2021" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37202", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37202 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37202.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37202" }, { "cve": "CVE-2021-37203", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37203 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37203.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37203" }, { "cve": "CVE-2021-41533", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41533 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41533.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41533" }, { "cve": "CVE-2021-41534", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41534 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41534.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41534" }, { "cve": "CVE-2021-41535", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41535 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41535.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41535" }, { "cve": "CVE-2021-41536", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41536 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41536.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41536" }, { "cve": "CVE-2021-41537", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41537 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41537.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41537" }, { "cve": "CVE-2021-41538", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.\n\nAn attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41538 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41538.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41538" }, { "cve": "CVE-2021-41539", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41539 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41539.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41539" }, { "cve": "CVE-2021-41540", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41540 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41540.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41540" } ] }
icsa-21-315-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens NX is affected by two vulnerabilities that could be triggered when the application reads OBJ files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system.\n\nSiemens has released updates for the NX and recommends to update to the latest version. Siemens recommends to avoid opening of untrusted files from unknown sources.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-328042.json" }, { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-328042.txt" }, { "category": "self", "summary": "SSA-328042: File Parsing Vulnerabilities in OBJ Translator in NX - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-08 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens NX OBJ Translator", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-08", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1973.3700", "product": { "name": "NX 1953 Series", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "NX 1953 Series" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1988", "product": { "name": "NX 1980 Series", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "NX 1980 Series" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-41535", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-41535 - NX 1953 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41535 - NX 1980 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41535 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41535.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1973.3700 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V1988 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-41535" }, { "cve": "CVE-2021-41538", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.\n\nAn attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-41538 - NX 1953 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41538 - NX 1980 Series", "url": "https://support.sw.siemens.com/" }, { "summary": "CVE-2021-41538 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41538.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1973.3700 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V1988 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-41538" } ] }
icsa-21-287-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "names": [ "xina1i" ], "summary": "reporting vulnerabilities CVE-2021-37202 and CVE-2021-37203" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure of CVE-2021-41533 through CVE-2021-41540" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released a new version for Solid Edge that fixes multiple file parsing vulnerabilities which could be triggered when the application reads files in IFC, JT or OBJ formats.\n\nIf a user is tricked to opening a malicious file using the affected application this could lead the application to crash, or potentially arbitrary code execution on the target host system.\n\nSiemens recommends to update to the latest version and to limit opening of files from unknown sources in the affected products.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-728618.json" }, { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-728618.txt" }, { "category": "self", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-287-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-287-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-287-06", "initial_release_date": "2021-09-28T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-28T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cSE2021MP8", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Solid Edge SE2021" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37202", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37202 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37202.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37202" }, { "cve": "CVE-2021-37203", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37203 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37203.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37203" }, { "cve": "CVE-2021-41533", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41533 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41533.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41533" }, { "cve": "CVE-2021-41534", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41534 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41534.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41534" }, { "cve": "CVE-2021-41535", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41535 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41535.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41535" }, { "cve": "CVE-2021-41536", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41536 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41536.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41536" }, { "cve": "CVE-2021-41537", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41537 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41537.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41537" }, { "cve": "CVE-2021-41538", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.\n\nAn attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41538 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41538.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41538" }, { "cve": "CVE-2021-41539", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41539 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41539.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41539" }, { "cve": "CVE-2021-41540", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41540 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41540.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41540" } ] }
fkie_cve-2021-41535
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-1119/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-1119/ | Third Party Advisory, VDB Entry |
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge | * | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | nx_1984_firmware | * | |
siemens | nx_1984 | - | |
siemens | nx_1988_firmware | * | |
siemens | nx_1988 | - | |
siemens | nx_1957_firmware | * | |
siemens | nx_1957 | - | |
siemens | nx_1961_firmware | * | |
siemens | nx_1961 | - | |
siemens | nx_1965_firmware | * | |
siemens | nx_1965 | - | |
siemens | nx_1969_firmware | * | |
siemens | nx_1969 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1", "versionEndExcluding": "se2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1984_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A7DCD3A-4441-4E9C-AE47-24098F07DED7", "versionEndExcluding": "1984", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1984:-:*:*:*:*:*:*:*", "matchCriteriaId": "56F1E031-1413-4DE0-8F05-DE1A9386420A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1988_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C8E5152-5B4A-4290-AED1-3687C6B0AA3E", "versionEndExcluding": "1984", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1988:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC5E1959-9A7C-4952-A3D7-AA36E9E6FAE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1957_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2522E4B-461C-4D62-B050-99DB97D6B292", "versionEndExcluding": "1973.3700", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1957:-:*:*:*:*:*:*:*", "matchCriteriaId": "5AC59921-B54E-4FCD-9759-79798F9482E5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1961_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DA28584-9BB3-4548-972F-0E72A20912F7", "versionEndExcluding": "1973.3700", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1961:-:*:*:*:*:*:*:*", "matchCriteriaId": "9D6529FE-F172-430A-8157-647D624C08E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1965_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9C5704-F07E-4CC2-B580-D9D8C3A83CCB", "versionEndExcluding": "1973.3700", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1965:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0BF4B7E-D26F-4D94-AD87-DDB67DD95450", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:nx_1969_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E752A21-139F-4A78-BECA-6C2E33007E00", "versionEndExcluding": "1973.3700", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:nx_1969:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A7965A5-E980-4044-A554-0E187883900E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771)." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en NX 1953 Series (Todas las versiones anteriores a V1973.3700), NX 1980 Series (Todas las versiones anteriores a V1988), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). La aplicaci\u00f3n afectada contiene una vulnerabilidad de uso despu\u00e9s de libre al analizar archivos OBJ. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual (ZDI-CAN-13771)" } ], "id": "CVE-2021-41535", "lastModified": "2024-11-21T06:26:22.013", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-09-28T12:15:08.093", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
ghsa-mvfm-jv7j-j8f4
Vulnerability from github
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).
{ "affected": [], "aliases": [ "CVE-2021-41535" ], "database_specific": { "cwe_ids": [ "CWE-416" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-09-28T12:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "id": "GHSA-mvfm-jv7j-j8f4", "modified": "2022-05-24T19:16:00Z", "published": "2022-05-24T19:16:00Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-41535" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119" } ], "schema_version": "1.4.0", "severity": [] }
cnvd-2021-75891
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf
Name | SIEMENS Solid Edge <SE2021MP8 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2021-41535", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-41535" } }, "description": "Solid Edge\u662f\u4e00\u6b3e3D CAD\u3001\u53c2\u6570\u5316\u7279\u5f81\u548c\u540c\u6b65\u6280\u672f\u5b9e\u4f53\u5efa\u6a21\u8f6f\u4ef6\u3002\n\nSiemens Solid Edge SE2021MP8\u4e4b\u524d\u7248\u672c\u5728\u89e3\u6790OBJ\u6587\u4ef6\u65f6\u5b58\u5728\u91ca\u653e\u540e\u91cd\u7528\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-75891", "openTime": "2021-10-11", "patchDescription": "Solid Edge\u662f\u4e00\u6b3e3D CAD\u3001\u53c2\u6570\u5316\u7279\u5f81\u548c\u540c\u6b65\u6280\u672f\u5b9e\u4f53\u5efa\u6a21\u8f6f\u4ef6\u3002\r\n\r\nSiemens Solid Edge SE2021MP8\u4e4b\u524d\u7248\u672c\u5728\u89e3\u6790OBJ\u6587\u4ef6\u65f6\u5b58\u5728\u91ca\u653e\u540e\u91cd\u7528\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens Solid Edge\u91ca\u653e\u540e\u91cd\u7528\u6f0f\u6d1e\uff08CNVD-2021-75891\uff09\u7684\u8865\u4e01", "products": { "product": "SIEMENS Solid Edge \u003cSE2021MP8" }, "referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2021-41535", "serverity": "\u4e2d", "submitTime": "2021-09-29", "title": "Siemens Solid Edge\u91ca\u653e\u540e\u91cd\u7528\u6f0f\u6d1e\uff08CNVD-2021-75891\uff09" }
gsd-2021-41535
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-41535", "description": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "id": "GSD-2021-41535" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-41535" ], "details": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "id": "GSD-2021-41535", "modified": "2023-12-13T01:23:27.609019Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-41535", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NX 1953 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1973.3700" } ] } }, { "product_name": "NX 1980 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1988" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All versions \u003c SE2021MP8" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416: Use After Free" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1984_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1984:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1988_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1988:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1957_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1957:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1961_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1961:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1965_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1965:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1969_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1969:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-41535" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-416" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1119/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2021-11-28T23:22Z", "publishedDate": "2021-09-28T12:15Z" } } }
CERTFR-2021-AVI-854
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Capital VSTAR versions incluant les modules DNS | ||
Siemens | N/A | Nucleus Source Code toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix 9 toutes versions antérieures à V9.6.2 | ||
Siemens | N/A | Nucleus NET toutes versions | ||
Siemens | N/A | SIMATIC WinCC V15 toutes versions | ||
Siemens | N/A | SIMATIC WinCC V17 toutes versions | ||
Siemens | N/A | SIMATIC WinCC OA V3.18 toutes versions | ||
Siemens | N/A | NX 1980 Series toutes versions antérieures à V1984 | ||
Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
Siemens | N/A | SIMATIC WinCC V7.5 toutes versions antérieures à V7.5 SP2 Update 5 | ||
Siemens | N/A | SIMATIC WinCC OA V3.17 toutes versions | ||
Siemens | N/A | Climatix POL909 (AWM module) toutes versions antérieures à V11.34 | ||
Siemens | N/A | SCALANCE W1750D toutes versions antérieures à V8.7.1.3 | ||
Siemens | N/A | SIMATIC PCS 7 V9.0 toutes versions | ||
Siemens | N/A | Siveillance Video DLNA Server 2021 R1 | ||
Siemens | N/A | SIMATIC PCS 7 V9.1 toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix 7 toutes versions antérieures à V7.23.26 | ||
Siemens | N/A | SIMATIC WinCC V7.4 toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
Siemens | N/A | Nucleus Source Code versions incluant les modules DNS | ||
Siemens | N/A | SIMATIC WinCC V16 toutes versions | ||
Siemens | N/A | SIMATIC Information Server toutes versions >= V2019 SP1 | ||
Siemens | N/A | SICAM 230 toutes versions | ||
Siemens | N/A | Nucleus ReadyStart V4 toutes versions antérieures à V4.1.1 | ||
Siemens | N/A | Mendix Applications using Mendix 8 toutes versions antérieures à V8.18.13 | ||
Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2017.02.4 | ||
Siemens | N/A | SIMATIC RTLS Locating Manager toutes versions antérieures à V2.12 | ||
Siemens | N/A | Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3 | ||
Siemens | N/A | Capital VSTAR toutes versions | ||
Siemens | N/A | Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3 | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2013.08 | ||
Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
Siemens | N/A | PSS(R)ODMS V12 toutes versions antérieures à V12.2.6.1 | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2012.12 | ||
Siemens | N/A | SENTRON powermanager V3 toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
Siemens | N/A | TALON TC Compact (BACnet) toutes versions | ||
Siemens | N/A | NX 1980 Series toutes versions antérieures à V1988 | ||
Siemens | N/A | PSS(R)E V34 toutes versions antérieures à V34.9.1 | ||
Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
Siemens | N/A | NX 1953 Series toutes versions antérieures à V1973.3700 | ||
Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
Siemens | N/A | PSS(R)E V35 toutes versions antérieures à V35.3.2 | ||
Siemens | N/A | SIMATIC PCS 7 V8.2 toutes versions | ||
Siemens | N/A | TALON TC Modular (BACnet) toutes versions |
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Capital VSTAR versions incluant les modules DNS", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus Source Code toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 9 toutes versions ant\u00e9rieures \u00e0 V9.6.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus NET toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V15 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V17 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC OA V3.18 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1984", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V7.5 toutes versions ant\u00e9rieures \u00e0 V7.5 SP2 Update 5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC OA V3.17 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Climatix POL909 (AWM module) toutes versions ant\u00e9rieures \u00e0 V11.34", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1750D toutes versions ant\u00e9rieures \u00e0 V8.7.1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V9.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2021 R1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V9.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 7 toutes versions ant\u00e9rieures \u00e0 V7.23.26", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V7.4 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus Source Code versions incluant les modules DNS", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V16 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC Information Server toutes versions \u003e= V2019 SP1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM 230 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V4 toutes versions ant\u00e9rieures \u00e0 V4.1.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 8 toutes versions ant\u00e9rieures \u00e0 V8.18.13", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2017.02.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RTLS Locating Manager toutes versions ant\u00e9rieures \u00e0 V2.12", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Capital VSTAR toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2013.08", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)ODMS V12 toutes versions ant\u00e9rieures \u00e0 V12.2.6.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2012.12", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SENTRON powermanager V3 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Compact (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1988", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)E V34 toutes versions ant\u00e9rieures \u00e0 V34.9.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1953 Series toutes versions ant\u00e9rieures \u00e0 V1973.3700", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)E V35 toutes versions ant\u00e9rieures \u00e0 V35.3.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V8.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Modular (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-27009", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27009" }, { "name": "CVE-2021-31881", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31881" }, { "name": "CVE-2020-28388", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28388" }, { "name": "CVE-2021-42026", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42026" }, { "name": "CVE-2021-37734", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37734" }, { "name": "CVE-2021-42025", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42025" }, { "name": "CVE-2021-37732", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37732" }, { "name": "CVE-2021-31888", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31888" }, { "name": "CVE-2020-27736", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27736" }, { "name": "CVE-2021-31885", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31885" }, { "name": "CVE-2021-31887", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31887" }, { "name": "CVE-2020-10053", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10053" }, { "name": "CVE-2021-37735", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37735" }, { "name": "CVE-2021-41533", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41533" }, { "name": "CVE-2021-25663", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25663" }, { "name": "CVE-2021-31884", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31884" }, { "name": "CVE-2021-42015", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42015" }, { "name": "CVE-2021-40366", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40366" }, { "name": "CVE-2020-15795", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15795" }, { "name": "CVE-2021-31882", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31882" }, { "name": "CVE-2021-25664", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25664" }, { "name": "CVE-2021-41057", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41057" }, { "name": "CVE-2021-37207", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37207" }, { "name": "CVE-2021-40358", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40358" }, { "name": "CVE-2020-10052", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10052" }, { "name": "CVE-2021-37726", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37726" }, { "name": "CVE-2020-10054", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10054" }, { "name": "CVE-2021-41535", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41535" }, { "name": "CVE-2021-37727", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37727" }, { "name": "CVE-2021-27393", "url": "https://www.cve.org/CVERecord?id=CVE-2021-27393" }, { "name": "CVE-2021-31346", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31346" }, { "name": "CVE-2021-40364", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40364" }, { "name": "CVE-2020-27738", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27738" }, { "name": "CVE-2021-31889", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31889" }, { "name": "CVE-2021-42021", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42021" }, { "name": "CVE-2021-31883", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31883" }, { "name": "CVE-2021-41538", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41538" }, { "name": "CVE-2021-40359", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40359" }, { "name": "CVE-2021-31886", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31886" }, { "name": "CVE-2021-41534", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41534" }, { "name": "CVE-2021-31890", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31890" }, { "name": "CVE-2021-37730", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37730" }, { "name": "CVE-2021-31345", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31345" }, { "name": "CVE-2020-27737", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27737" }, { "name": "CVE-2021-31344", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31344" }, { "name": "CVE-2021-25677", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25677" } ], "initial_release_date": "2021-11-09T00:00:00", "last_revision_date": "2021-11-09T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-854", "revisions": [ { "description": "Version initiale", "revision_date": "2021-11-09T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-248289 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-703715 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-703715.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-840188 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-362164 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-044112 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-328042 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917476 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-201384 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-201384.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-537983 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-779699 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-580693 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185699 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-740908 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-740908.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-145157 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-338732 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-755517 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705111 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf" } ] }
CERTFR-2021-AVI-739
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans Siemens Solid Edge. Elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneTitle | Publication Time | Tags | |||
---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Solid Edge versions ant\u00e9rieures \u00e0 SE2021 MP8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-41536", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41536" }, { "name": "CVE-2021-41533", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41533" }, { "name": "CVE-2021-41539", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41539" }, { "name": "CVE-2021-41540", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41540" }, { "name": "CVE-2021-37202", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37202" }, { "name": "CVE-2021-41535", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41535" }, { "name": "CVE-2021-37203", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37203" }, { "name": "CVE-2021-41538", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41538" }, { "name": "CVE-2021-41537", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41537" } ], "initial_release_date": "2021-09-28T00:00:00", "last_revision_date": "2021-09-28T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-739", "revisions": [ { "description": "Version initiale", "revision_date": "2021-09-28T00:00:00.000000" } ], "risks": [ { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Ex\u00e9cution de code arbitraire" }, { "description": "D\u00e9ni de service" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Siemens Solid Edge.\nElles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code\narbitraire, un d\u00e9ni de service et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des\ndonn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans Siemens Solid Edge", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-728618 du 28 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ] }
var-202109-1792
Vulnerability from variot
A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of OBJ files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "nx 1969", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1973.3700" }, { "_id": null, "model": "nx 1984", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1984" }, { "_id": null, "model": "nx 1961", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1973.3700" }, { "_id": null, "model": "nx 1965", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1973.3700" }, { "_id": null, "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "_id": null, "model": "solid edge", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "_id": null, "model": "nx 1988", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1984" }, { "_id": null, "model": "nx 1957", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1973.3700" }, { "_id": null, "model": "solid edge viewer", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "NVD", "id": "CVE-2021-41535" } ] }, "configurations": { "_id": null, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1984_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1984:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1984_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1984:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1988_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1988:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1988_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1988:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1957_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1957:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1957_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1957:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1961_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1961:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1961_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1961:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1965_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1965:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1965_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1965:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1969_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:nx_1969:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:nx_1969_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1973.3700", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:siemens:nx_1969:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-41535" } ] }, "credits": { "_id": null, "data": "xina1i", "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "CNNVD", "id": "CNNVD-202109-1837" } ], "trust": 1.3 }, "cve": "CVE-2021-41535", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-41535", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-41535", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-41535", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-41535", "trust": 1.0, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2021-41535", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202109-1837", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-41535", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "VULMON", "id": "CVE-2021-41535" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-1837" }, { "db": "NVD", "id": "CVE-2021-41535" } ] }, "description": { "_id": null, "data": "A vulnerability has been identified in NX 1953 Series (All versions \u003c V1973.3700), NX 1980 Series (All versions \u003c V1988), Solid Edge SE2021 (All versions \u003c SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of OBJ files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-41535" }, { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-41535" } ], "trust": 2.16 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2021-41535", "trust": 2.4 }, { "db": "ZDI", "id": "ZDI-21-1119", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-728618", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-328042", "trust": 1.6 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-13771", "trust": 0.7 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021092905", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021111007", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.3454", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.3874", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-315-08", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-287-06", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202109-1837", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-41535", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "VULMON", "id": "CVE-2021-41535" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-1837" }, { "db": "NVD", "id": "CVE-2021-41535" } ] }, "id": "VAR-202109-1792", "iot": { "_id": null, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.19128205 }, "last_update_date": "2022-05-04T07:50:56.011000Z", "patch": { "_id": null, "data": [ { "title": "", "trust": 0.7, "url": "https://www.siemens.com/cert/advisories/https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "title": "Siemens Solid Edge Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=164366" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=3b85ee03e935aff52e55e7402b3926a1" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "VULMON", "id": "CVE-2021-41535" }, { "db": "CNNVD", "id": "CNNVD-202109-1837" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-416", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-41535" } ] }, "references": { "_id": null, "data": [ { "trust": 2.4, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-1119/" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "trust": 0.7, "url": "https://www.siemens.com/cert/advisories/https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-287-06" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.3874" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.3454" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-41535" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021092905" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-315-08" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021111007" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/416.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" }, { "db": "VULMON", "id": "CVE-2021-41535" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-1837" }, { "db": "NVD", "id": "CVE-2021-41535" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-21-1119", "ident": null }, { "db": "VULMON", "id": "CVE-2021-41535", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202109-1837", "ident": null }, { "db": "NVD", "id": "CVE-2021-41535", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2021-09-30T00:00:00", "db": "ZDI", "id": "ZDI-21-1119", "ident": null }, { "date": "2021-09-28T00:00:00", "db": "VULMON", "id": "CVE-2021-41535", "ident": null }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "date": "2021-09-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1837", "ident": null }, { "date": "2021-09-28T12:15:00", "db": "NVD", "id": "CVE-2021-41535", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2021-09-30T00:00:00", "db": "ZDI", "id": "ZDI-21-1119", "ident": null }, { "date": "2021-10-01T00:00:00", "db": "VULMON", "id": "CVE-2021-41535", "ident": null }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "date": "2021-11-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1837", "ident": null }, { "date": "2021-11-28T23:22:00", "db": "NVD", "id": "CVE-2021-41535", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1837" } ], "trust": 0.6 }, "title": { "_id": null, "data": "Siemens Solid Edge Viewer OBJ File Parsing Use-After-Free Remote Code Execution Vulnerability", "sources": [ { "db": "ZDI", "id": "ZDI-21-1119" } ], "trust": 0.7 }, "type": { "_id": null, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.