cve-2021-40359
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Summary
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
Impacted products
Vendor Product Version
Siemens OpenPCS 7 V9.0 Version: All versions < V9.0 Upd4
Siemens OpenPCS 7 V9.1 Version: All versions
Siemens SIMATIC BATCH V8.2 Version: All versions
Siemens SIMATIC BATCH V9.0 Version: All versions
Siemens SIMATIC BATCH V9.1 Version: All versions
Siemens SIMATIC NET PC Software V14 Version: All versions
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC NET PC Software V16 Version: All versions < V16 Update 6
Siemens SIMATIC NET PC Software V17 Version: All versions < V17 SP1
Siemens SIMATIC PCS 7 V8.2 Version: All versions
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3 UC04
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1
Siemens SIMATIC Route Control V8.2 Version: All versions
Siemens SIMATIC Route Control V9.0 Version: All versions
Siemens SIMATIC Route Control V9.1 Version: All versions
Siemens SIMATIC WinCC V15 and earlier Version: All versions < V15 SP1 Update 7
Siemens SIMATIC WinCC V16 Version: All versions < V16 Update 5
Siemens SIMATIC WinCC V17 Version: All versions < V17 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 19
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 5
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.625Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3 UC04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V15 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15 SP1 Update 7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 6), SIMATIC NET PC Software V17 (All versions \u003c V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:59.282Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40359",
    "datePublished": "2021-11-09T11:32:05",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-40359\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-11-09T12:15:09.987\",\"lastModified\":\"2024-11-21T06:23:56.917\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 6), SIMATIC NET PC Software V17 (All versions \u003c V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V9.0 Upd4), OpenPCS 7 V9.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones), SIMATIC BATCH V9. 1 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V16 Update 6), SIMATIC NET PC Software V17 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V17 SP1), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9. 0 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V9.1 SP1), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones), SIMATIC Route Control V9. 1 (Todas las versiones), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a la versi\u00f3n a la versi\u00f3n V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP2 Update 5). Al descargar archivos, los sistemas afectados no neutralizan correctamente los elementos especiales dentro del nombre de la ruta. Un atacante podr\u00eda entonces hacer que el nombre de ruta se resuelva en una ubicaci\u00f3n fuera del directorio restringido en el servidor y leer archivos cr\u00edticos inesperados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N\",\"baseScore\":7.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.1,\"impactScore\":4.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:8.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CAFD7F2-BB23-4E3A-A30E-78290D5EAB47\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:8.2:upd_9:*:*:*:*:*:*\",\"matchCriteriaId\":\"F043FAC3-661C-4226-AA70-7EF836DDBA55\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E54F6E83-C353-44FB-9F37-C03DA344A5DC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E19D98B-B40A-4589-8C26-7722C25EEC63\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"85CDD274-B2B4-4DB0-9917-C16B5D900006\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B435D51-FFA2-4F19-9B51-404BB37D7F0D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_3:*:*:*:*:*:*\",\"matchCriteriaId\":\"AFBBC7D6-D1D4-452E-A744-B490CF002354\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_4:*:*:*:*:*:*\",\"matchCriteriaId\":\"98BC62E3-4C0B-481A-9274-B9C785F8FDC5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4598FFB9-68FC-4825-83AB-4B1D45C3B3E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"298E8F34-346B-4FC5-8690-3F947F585552\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7DF90C44-4AC2-4B2B-8712-30CD3DE96B22\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"496E3C43-5DA8-4983-8AC6-0F32454E22F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"17BCC3CD-61D0-416D-A241-D35AF8EE5BF8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"AFBD6DDF-917C-44CC-A944-1945DC7AC9FB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_route_control:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F8A4F12-33E8-47CD-9790-60D0D39E6965\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"57073CE8-174E-429D-A721-AB14C7D16D4F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_route_control:9.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"588E365B-D148-4253-A316-63FD11821F85\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.4\",\"matchCriteriaId\":\"CA2E9785-246F-496B-9139-02E2F4003352\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E79DA14E-419C-49BA-8E4F-2907E1D8937F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"81F9C13C-065C-4E40-BB46-687D791348A9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"5CF06E69-0A23-418D-B0EC-574DACBB4DD9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"9164EAC1-C416-4F1F-A910-CE84A167A6D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"3422B714-DB0F-4EE3-A7D4-9A0165214563\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"70B79B00-F61D-4F10-AD7B-74718F061D9E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8766442-CC8D-4221-89B8-F75D195F71E8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C08FB9-AFEB-4A53-AAB3-37C9717B30C5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"68896900-7FCC-4BFB-B787-8992B459F00D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:15:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"1ECA9805-26BE-4A3E-B418-A35DC1211AEF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4316924-9EF8-4835-A2E4-0C81F4DE473D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1011EBE-A08D-4066-A2B8-45736AE6999B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"37284D6C-ADB9-43A9-817D-7879FDF8BF7F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DAD73CB-A027-4CEA-A439-A271717BBEDD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"150B957C-545F-4BD8-8AB9-E64ACC59C865\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C665E91E-DC56-41E0-99B4-ACFAA70B3103\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB46C8BD-942A-45DC-AA8A-C0D9418CA302\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simaticpcs_7:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.2\",\"matchCriteriaId\":\"382FA06B-0465-4CA0-B0D7-B7BB748B2574\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simaticpcs_7:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0\",\"versionEndExcluding\":\"9.1\",\"matchCriteriaId\":\"99CCAC08-D8F5-416D-82EC-7F8E1BC69C57\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simaticpcs_7:9.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFC56795-0196-49AD-A840-3EBAB83D4587\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.